Installing Windows NT Server, Enterprise Edition (ES2045R)<br />

on enabling 4GB RAM Tuning (4GT), see the Windows NT Server/E<br />

Administrator’s <strong>Guide</strong>. You can find this guide in two places: in<br />

\Support\Books\NTSEAdm.hlp <strong>and</strong> in the readme.doc file in the root<br />

directory of the Windows NT Server/E Base CD.<br />

23. Click OK.<br />

A window appears displaying Microsoft Windows NT Server, Enterprise Edition<br />

Installer.<br />

24. Clear the check box “Show this installer next time you start Windows NT.”<br />

25. Click Continue, then click Exit.<br />

A prompt asks if you are sure.<br />

26. Click Yes.<br />

Continue by configuring the hosts file (7.1.3).<br />

5.3. Configuring the RAID Controller<br />

Configure the RAID disk controller for RAID level 1 (mirroring) for two disks units.<br />

Sites can reconfigure a different RAID level following hardware RFU if desired. For<br />

detailed information see the MegaRAID <strong>and</strong> MegaRAID Ultra PCI SCSI Disk Array<br />

Controller User’s <strong>Guide</strong>.<br />

Notes:<br />

• Switch the monitor concentrator to the Intel node position before beginning (see<br />

2.5.2).<br />

• If you are performing a full installation on a system that was preloaded, do not<br />

format the RAID disk. Instead, use the DAC BIOS utility to initialize the RAID<br />

volume before you reload the operating system. Formatting the disk makes the drive<br />

unrecognizable to the software.<br />

• In step 2, you must press Ctrl-M within a few seconds to enter the RAID controller<br />

configuration procedure, otherwise the normal boot procedure continues.<br />

Take the following steps to run the RAID controller configuration utility:<br />

1. Power on or reboot the Intel node.<br />

Several start-up messages appear including a prompt to press Ctrl-M as follows:<br />

MEGARAID ULTRA PCI ADAPTER BIOS VERSION x.xx<br />

Copyright(c) AMERICAN MEGATRENDS INC.<br />

Host Adapter-1 Firmware Version x.xx DRAM size xxx MB<br />

1 Logical Drives found on the Host Adapter<br />

1 Logical Drives h<strong>and</strong>led by BIOS<br />

><br />

2. Press Ctrl-M to start the RAID BIOS configuration utility.<br />

7850 5104–009 Version 009B (Web Only) 5–9