SOLIDWORKS ElectricalViewer ZoneDisplays the selected drawing. The software displays one drawing at a time. The drawingsare read-only and you can only use zoom commands.Reimport Electrical Data for Wires, Cables, andHarnessesYou can remove unused sketch segments from wires, cables, and harnesses.If you remove a wire or core from electrical routes, cables or harnesses in SOLIDWORKSElectrical Schematics, when you reimport that model, the software removes the wire orcore from the model in SOLIDWORKS Electrical 3D.If you delete a wire style from a route assembly in SOLIDWORKS Electrical Schematics,when you reimport that model, the software deletes that particular route assembly fromSOLIDWORKS Electrical 3D.Routing ParametersYou can set the routing parameters to create electrical harnesses from the Route harnessesPropertyManager.Enhanced largeassemblyperformanceManual harnessGenerate fan-outsSuppresses all the 3D parts of large assemblies to enhanceperformance.Adds the components to the harness and creates guidelines.Select this to manually finish the harness.Creates fan-outs for multipin connectors. This option is enabledwhen you select Manual harness.Report Enhancements for Rows and ColumnsYou can add a column that specifies the row number and controls the row height in reports.Row Height in ReportsYou can set the row height. The software ensures that the row height is not less than thefont size.To control the row height, on the Project tab, click Reports > Properties >Report configuration edition > Styles and set the Row height.This functionality applies to Header, Content, and Total.102

SOLIDWORKS ElectricalRow StyleAutomaticMinimum heightFixed heightApplies the default value for the row height.Applies the minimum height entered in Row height. Applicablefor multiple lines in a row.Applies the fixed height entered in Row height. Applicable fora single line in a row.Row HeightEnter the row height.Row Number Column in ReportsYou can add a column in a report that specifies the row number of the report entity.You can configure the row number and define a base number in the report template. Therow numbers are consecutive and auto assigned in the report manager and reportdrawings.The row numbers are still consecutive when you apply the following operations:• Filter• Sort• Merge• BreakUse the following variables to keep row numbers consecutive after a break:• REPORT_ROW_GLOBAL. Applies consecutive row numbers to the entire row.• REPORT_ROW. Applies consecutive row numbers to each report table that has breaks.User Rights ManagerYou can archive custom user profiles, customize the feature grid, control the deletionrights of user profiles, and create a user-defined profile from the User rights manager.Archive EnvironmentYou can archive and unarchive the environment, user-defined profiles, and linked features.A notification appears when there is a mismatch between the number of profiles duringarchiving and unarchiving.103

SOLIDWORKS Electrical

Viewer Zone

Displays the selected drawing. The software displays one drawing at a time. The drawings

are read-only and you can only use zoom commands.

Reimport Electrical Data for Wires, Cables, and

Harnesses

You can remove unused sketch segments from wires, cables, and harnesses.

If you remove a wire or core from electrical routes, cables or harnesses in SOLIDWORKS

Electrical Schematics, when you reimport that model, the software removes the wire or

core from the model in SOLIDWORKS Electrical 3D.

If you delete a wire style from a route assembly in SOLIDWORKS Electrical Schematics,

when you reimport that model, the software deletes that particular route assembly from

SOLIDWORKS Electrical 3D.

Routing Parameters

You can set the routing parameters to create electrical harnesses from the Route harnesses

PropertyManager.

Enhanced large

assembly

performance

Manual harness

Generate fan-outs

Suppresses all the 3D parts of large assemblies to enhance

performance.

Adds the components to the harness and creates guidelines.

Select this to manually finish the harness.

Creates fan-outs for multipin connectors. This option is enabled

when you select Manual harness.

Report Enhancements for Rows and Columns

You can add a column that specifies the row number and controls the row height in reports.

Row Height in Reports

You can set the row height. The software ensures that the row height is not less than the

font size.

To control the row height, on the Project tab, click Reports > Properties >

Report configuration edition > Styles and set the Row height.

This functionality applies to Header, Content, and Total.