98 Index<br />

disabled<br />

output voter diagnostics 23<br />

points alarm 23, 61<br />

Download All command 23<br />

Download Change command 48<br />

E<br />

emergency shutdown systems, guidelines 21<br />

errors in external communication 18<br />

errors, array index 47<br />

EX01_shutdown programs 51<br />

EX02_shutdown programs 55<br />

EX03_shutdown programs 60<br />

external communication<br />

diagnostics 43–44<br />

errors in 18<br />

safety measures <strong>for</strong> 18<br />

external faults 36<br />

external write modes 25<br />

F<br />

factors<br />

SIL 4<br />

SIS 5<br />

fault reporting times, diagnostic calculation 41<br />

faults, types of 36<br />

feedback message safety measure 19<br />

fire and gas systems, guidelines 21<br />

flags, semaphore 43<br />

function blocks<br />

defining <strong>for</strong> safety-critical modules 58<br />

Peer-to-Peer 68–70<br />

SYS_CRITICAL_I/O 83–87<br />

SYS_SHUTDOWN 88–93<br />

SYS_VOTE_MODE 94–96<br />

TR_SEND 68, 70<br />

TR_URCV 68–70<br />

functions, Modbus master 23<br />

G<br />

guidelines<br />

all safety systems 17–20<br />

burner management systems 21<br />

controllers 22<br />

development 46<br />

disabled output voter diagnostics 23<br />

disabled points alarm 23, 61<br />

Download All command 23<br />

emergency shutdown systems 21<br />

fire and gas systems 21<br />

<strong>for</strong> controller 22<br />

maintenance overrides 27–30<br />

<strong>Safety</strong> <strong>Considerations</strong> <strong>Guide</strong> <strong>for</strong> <strong>Trident</strong> <strong>v2</strong> <strong>Systems</strong><br />

guidelines (continued)<br />

Modbus master functions 23<br />

Peer-to-Peer communication 23–25<br />

programming permitted alarm 61<br />

remote access alarm 61<br />

response time 23, 61<br />

safety system boundary 30<br />

safety-critical modules 22<br />

safety-shutdown systems 23<br />

scan time 23, 61<br />

SIL fire and gas 26<br />

SILs 25–26<br />

H<br />

hazard and risk analysis 5<br />

HAZOP 5, 6<br />

I<br />

I/O modules<br />

alarms 42<br />

processing 42<br />

system-critical 51<br />

IEC 61508, parts 1–7 12<br />

incorrect sequence error 18<br />

infinite loops 47<br />

input module alarms<br />

analog 38<br />

digital 39<br />

input module diagnostics<br />

analog 38<br />

digital 39<br />

pulse 40<br />

insertion error 18<br />

internal faults 36<br />

L<br />

layers, protection 3, 5<br />

loss error 18<br />

M<br />

main processors<br />

diagnostics 42<br />

system attributes 43<br />

Tribus 42<br />

maintenance overrides<br />

design requirements <strong>for</strong> handling 28<br />

documentation of 29<br />

guidelines 27–30<br />

operating requirements <strong>for</strong> handling 29<br />

serial communications 27<br />

masquerade error 18