Re-powering Study for the Northport <strong>and</strong> Port Jefferson Power Stations<br />

<strong>Appendix</strong> IV Northport <strong>Plan</strong>t Equipment List<br />

Backyard Option Equipment List<br />

Combustion Turbine Typical Scope of S<strong>up</strong>ply<br />

System System Scope<br />

ENGINE ASSEMBLY Co<strong>up</strong>ling to Generator, Dry Chemical Exhaust Bearing Fire Protection<br />

Engine Assembly with<br />

Bedplate<br />

Walk-in acoustical<br />

enclosure<br />

MECHANICAL<br />

PACKAGE<br />

Lubricating Oil System<br />

<strong>and</strong> Control Oil System<br />

ELECTRICAL<br />

PACKAGE<br />

INLET AND EXHAUST<br />

SYSTEMS<br />

FUEL SYSTEMS<br />

N.Gas System<br />

System, Insulation Blankets, Platforms, Stairs <strong>and</strong> Ladders<br />

Variable Inlet Guide Vane System, Compressor, Bleed System, Purge Air<br />

System, Bearing Seal Air System, Combustors, Dual Fuel Nozzles, Turbine<br />

Rotor Cooler<br />

HVAC, Lighting, <strong>and</strong> Low Pressure CO2 Fire Protection System<br />

HVAC <strong>and</strong> Lighting, Air Compressor for Pneumatic System, Low Pressure<br />

C02 Fire Protection System<br />

Lube Oil Reservoir, Accumulators, AC Driven Oil Pumps, DC Emergency Oil<br />

Pump with Starter, Oil Coolers, D<strong>up</strong>lex Oil Filter, Oil Temperature <strong>and</strong><br />

Pressure Control Valves, Oil Vapor Exhaust Fans <strong>and</strong> Demister, Oil<br />

Heaters, Oil Interconnect Piping (SS <strong>and</strong> CS), Oil System Instrumentation,<br />

Oil for Flushing <strong>and</strong> First Filling<br />

HVAC <strong>and</strong> Lighting, AC <strong>and</strong> DC Motor Control Centers, Generator Voltage<br />

Regulating Cabinet, Generator Protective Relay Cabinet, DC Distribution<br />

Panel, Battery Charger, Digital Control System with Local Control Panel (all<br />

control <strong>and</strong> monitoring functions as well as data logger <strong>and</strong> sequence of<br />

events recorder), Control System Valves <strong>and</strong> Instrumentation<br />

Communication link for interface with plant DCS S<strong>up</strong>ervisory System,<br />

Vibration Monitoring System, Low Pressure C02 Fire Protection System,<br />

Cable Tray <strong>and</strong> Conduit Provisions for Performance Testing including Test<br />

Ports, Thermowells, Instrumentation <strong>and</strong> DCS interface cards<br />

Inlet Duct Trash Screens, Inlet Duct <strong>and</strong> Silencers, Self Cleaning Filters,<br />

Hoist System For Filter Maintenance, Evaporative Cooler System, Exhaust<br />

Duct Expansion Joint, Exhaust Silencers Inlet <strong>and</strong> Exhaust Flow, Pressure<br />

<strong>and</strong> Temperature Ports <strong>and</strong> Instrumentation<br />

Gas Valves Including Vent, Throttle <strong>and</strong> Trip Valves, Gas Filter/Separator,<br />

Gas S<strong>up</strong>ply Instruments <strong>and</strong> Instrument Panel<br />

STARTING SYSTEM Static Start System, Turning Gear <strong>and</strong> Clutch Assembly,<br />

GENERATOR Static (including excitation transformer), Line Termination Enclosure with<br />

CTs, VTs, Surge Arrestors, <strong>and</strong> Surge Capacitors, Neutral Cubicle with CT,<br />

Neutral Tie Bus, Grounding Transformer, <strong>and</strong> Secondary Resistor,<br />

Generator Gas Dryer, Seal Oil System (including Defoaming Tank,<br />

Reservoir, Seal Oil Pump, Emergency Seal Oil Pump, Vapor Extractor, <strong>and</strong><br />

Oil Mist Eliminator), Generator Auxiliaries Control Enclosure, Generator<br />

Breaker, Iso-Phase bus connecting generator <strong>and</strong> breaker, Grounding<br />

System Connectors<br />

Generator Cooling Hydrogen Cooling System (including H2 to Glycol <strong>and</strong> Glycol to Air heat<br />

exchangers, liquid level detector circulation system, interconnecting piping<br />

<strong>and</strong> controls)<br />

MISCELLANEOUS Interconnecting Pipe, Wire, Tubing <strong>and</strong> Cable Instrument Air System<br />

Including Air Dryer On Line <strong>and</strong> Off Line Water Wash System LP CO2<br />

Storage Tank Drain System Drain Tanks Co<strong>up</strong>ling, Co<strong>up</strong>ling Cover <strong>and</strong><br />

Associated Hardware<br />