Accessory Electric Plant Re-powering Study for the Northport and Port Jefferson Power Stations Appendix IV Northport Plant Equipment List Equipment No. Description Type 1 CTG Transformers 2-Oil-filled 290 MVA 18kV/345 kV 2 STG Transformer 1-Oil-filled 300 MVA 22 kV/345 kV 3 Auxiliary Transformers 2-Oil-filled 10 MVA 18 kV/4.16 kV 4 Generator Breaker 2, one for each CT 5 High Side GIS Breaker 3, one for each CTG and one for the STG 6 Low Voltage Transformer Dry ventilated 4.16 kV/480V 7 CTG Isolated Phase Bus Ducts and Tap Bus Aluminum, self-cooled 18 kV 8 Medium Voltage Switchgear Metal clad 9 Low Voltage Switchgear Instrumentation and Control Metal enclosed Equipment No. Description Type 1 DCS-Main Control Monitor/keyboard; Operator printer; Engineering printer 2 DCS- Processor Microprocessor with redundant input/output 3 DCS-Data Highway Fiber optic March 30, 2009 228
Re-powering Study for the Northport and Port Jefferson Power Stations Appendix IV Northport Plant Equipment List Backyard Option Equipment List Combustion Turbine Typical Scope of Supply System System Scope ENGINE ASSEMBLY Coupling to Generator, Dry Chemical Exhaust Bearing Fire Protection Engine Assembly with Bedplate Walk-in acoustical enclosure MECHANICAL PACKAGE Lubricating Oil System and Control Oil System ELECTRICAL PACKAGE INLET AND EXHAUST SYSTEMS FUEL SYSTEMS N.Gas System System, Insulation Blankets, Platforms, Stairs and Ladders Variable Inlet Guide Vane System, Compressor, Bleed System, Purge Air System, Bearing Seal Air System, Combustors, Dual Fuel Nozzles, Turbine Rotor Cooler HVAC, Lighting, and Low Pressure CO2 Fire Protection System HVAC and Lighting, Air Compressor for Pneumatic System, Low Pressure C02 Fire Protection System Lube Oil Reservoir, Accumulators, AC Driven Oil Pumps, DC Emergency Oil Pump with Starter, Oil Coolers, Duplex Oil Filter, Oil Temperature and Pressure Control Valves, Oil Vapor Exhaust Fans and Demister, Oil Heaters, Oil Interconnect Piping (SS and CS), Oil System Instrumentation, Oil for Flushing and First Filling HVAC and Lighting, AC and DC Motor Control Centers, Generator Voltage Regulating Cabinet, Generator Protective Relay Cabinet, DC Distribution Panel, Battery Charger, Digital Control System with Local Control Panel (all control and monitoring functions as well as data logger and sequence of events recorder), Control System Valves and Instrumentation Communication link for interface with plant DCS Supervisory System, Vibration Monitoring System, Low Pressure C02 Fire Protection System, Cable Tray and Conduit Provisions for Performance Testing including Test Ports, Thermowells, Instrumentation and DCS interface cards Inlet Duct Trash Screens, Inlet Duct and Silencers, Self Cleaning Filters, Hoist System For Filter Maintenance, Evaporative Cooler System, Exhaust Duct Expansion Joint, Exhaust Silencers Inlet and Exhaust Flow, Pressure and Temperature Ports and Instrumentation Gas Valves Including Vent, Throttle and Trip Valves, Gas Filter/Separator, Gas Supply Instruments and Instrument Panel STARTING SYSTEM Static Start System, Turning Gear and Clutch Assembly, GENERATOR Static (including excitation transformer), Line Termination Enclosure with CTs, VTs, Surge Arrestors, and Surge Capacitors, Neutral Cubicle with CT, Neutral Tie Bus, Grounding Transformer, and Secondary Resistor, Generator Gas Dryer, Seal Oil System (including Defoaming Tank, Reservoir, Seal Oil Pump, Emergency Seal Oil Pump, Vapor Extractor, and Oil Mist Eliminator), Generator Auxiliaries Control Enclosure, Generator Breaker, Iso-Phase bus connecting generator and breaker, Grounding System Connectors Generator Cooling Hydrogen Cooling System (including H2 to Glycol and Glycol to Air heat exchangers, liquid level detector circulation system, interconnecting piping and controls) MISCELLANEOUS Interconnecting Pipe, Wire, Tubing and Cable Instrument Air System Including Air Dryer On Line and Off Line Water Wash System LP CO2 Storage Tank Drain System Drain Tanks Coupling, Coupling Cover and Associated Hardware March 30, 2009 229
- Page 40 and 41: 1 2 3 4 5 6 7 8 9 10 A 0831 PID-08-
- Page 42 and 43: 1 2 3 4 5 6 7 8 9 10 A 0427 PID-04-
- Page 44 and 45: 1 2 3 4 5 6 7 8 9 10 A FGS FGS FGS
- Page 46 and 47: 1 2 3 4 5 6 7 8 9 10 A 0823 PID-08-
- Page 50 and 51: 1 2 3 4 5 6 7 8 9 10 0904 PID-09-09
- Page 52 and 53: 1 2 3 4 5 6 7 8 9 10 A FROM AIR COM
- Page 54 and 55: 1 2 3 4 5 6 7 8 9 10 A REVISION DES
- Page 56 and 57: 1 2 3 4 5 6 7 8 9 10 A 1330 PID-13-
- Page 58 and 59: 1 2 3 4 5 6 7 8 9 10 A FROM HRSG 1A
- Page 60 and 61: 1 2 3 4 5 6 7 8 9 10 A 0304 PID-03-
- Page 62 and 63: 1 2 3 4 5 6 7 8 9 10 A 0341 PID-03-
- Page 64 and 65: 1 2 3 4 5 6 7 8 9 10 A 0368 PID-03-
- Page 66 and 67: 1 2 3 4 5 6 7 8 9 10 A REVISION DES
- Page 68 and 69: 1 2 3 4 5 6 7 8 9 10 A 0831 PID-08-
- Page 70 and 71: 1 2 3 4 5 6 7 8 9 10 A 0427 PID-04-
- Page 72 and 73: 1 2 3 4 5 6 7 8 9 10 A FGS FGS FGS
- Page 74 and 75: 1 2 3 4 5 6 7 8 9 10 A 0823 PID-08-
- Page 76 and 77: 1 2 3 4 5 6 7 8 9 10 CCW VSH 0132A
- Page 78 and 79: 1 2 3 4 5 6 7 8 9 10 0904 PID-09-09
- Page 80 and 81: 1 2 3 4 5 6 7 8 9 10 A FROM AIR COM
- Page 82 and 83: 1 2 3 4 5 6 7 8 9 10 A REVISION DES
- Page 84 and 85: 1 2 3 4 5 6 7 8 9 10 A 1330 PID-13-
- Page 86 and 87: Re-powering Study for the Northport
- Page 88 and 89: Fuel Systems Re-powering Study for
- Page 92 and 93: Fuel and Feed Re-powering Study for
- Page 94 and 95: Accessory Electric Plant Re-powerin
- Page 96 and 97: Re-powering Study for the Northport
- Page 98 and 99: Re-powering Study for the Northport
- Page 100 and 101: Re-powering Study for the Northport
- Page 102 and 103: Re-powering Study for the Northport
- Page 104 and 105: Re-powering Study for the Northport
- Page 106 and 107: Re-powering Study for the Northport
- Page 108 and 109: Re-powering Study for the Northport
- Page 110 and 111: • Grounding and lightning protect
- Page 112 and 113: Re-powering Study for the Northport
- Page 114 and 115: • Combustion turbine foundation
- Page 116 and 117: D3 Fuel Oil facilities Re-powering
- Page 118 and 119: Re-powering Study for the Northport
Accessory Electric <strong>Plan</strong>t<br />
Re-powering Study for the Northport <strong>and</strong> Port Jefferson Power Stations<br />
<strong>Appendix</strong> IV Northport <strong>Plan</strong>t Equipment List<br />
Equipment<br />
No.<br />
Description Type<br />
1 CTG<br />
Transformers<br />
2-Oil-filled 290 MVA 18kV/345 kV<br />
2 STG<br />
Transformer<br />
1-Oil-filled 300 MVA 22 kV/345 kV<br />
3 Auxiliary<br />
Transformers<br />
2-Oil-filled 10 MVA 18 kV/4.16 kV<br />
4 Generator<br />
Breaker<br />
2, one for each CT<br />
5 High Side GIS<br />
Breaker<br />
3, one for each CTG <strong>and</strong> one for the STG<br />
6 Low Voltage<br />
Transformer<br />
Dry ventilated 4.16 kV/480V<br />
7 CTG Isolated<br />
Phase Bus<br />
Ducts <strong>and</strong> Tap<br />
Bus<br />
Aluminum, self-cooled 18 kV<br />
8 Medium<br />
Voltage<br />
Switchgear<br />
Metal clad<br />
9 Low Voltage<br />
Switchgear<br />
Instrumentation <strong>and</strong> Control<br />
Metal enclosed<br />
Equipment<br />
No.<br />
Description Type<br />
1 DCS-Main<br />
Control<br />
Monitor/keyboard; Operator printer; Engineering printer<br />
2 DCS-<br />
Processor<br />
Microprocessor with redundant input/output<br />
3 DCS-Data<br />
Highway<br />
Fiber optic<br />
March 30, 2009 228