Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ... Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

23.12.2012 Views

Accessory Electric Plant Re-powering Study for the Northport and Port Jefferson Power Stations Appendix IV Northport Plant Equipment List Equipment No. Description Type 1 CTG Transformers 2-Oil-filled 290 MVA 18kV/345 kV 2 STG Transformer 1-Oil-filled 300 MVA 22 kV/345 kV 3 Auxiliary Transformers 2-Oil-filled 10 MVA 18 kV/4.16 kV 4 Generator Breaker 2, one for each CT 5 High Side GIS Breaker 3, one for each CTG and one for the STG 6 Low Voltage Transformer Dry ventilated 4.16 kV/480V 7 CTG Isolated Phase Bus Ducts and Tap Bus Aluminum, self-cooled 18 kV 8 Medium Voltage Switchgear Metal clad 9 Low Voltage Switchgear Instrumentation and Control Metal enclosed Equipment No. Description Type 1 DCS-Main Control Monitor/keyboard; Operator printer; Engineering printer 2 DCS- Processor Microprocessor with redundant input/output 3 DCS-Data Highway Fiber optic March 30, 2009 228

Re-powering Study for the Northport and Port Jefferson Power Stations Appendix IV Northport Plant Equipment List Backyard Option Equipment List Combustion Turbine Typical Scope of Supply System System Scope ENGINE ASSEMBLY Coupling to Generator, Dry Chemical Exhaust Bearing Fire Protection Engine Assembly with Bedplate Walk-in acoustical enclosure MECHANICAL PACKAGE Lubricating Oil System and Control Oil System ELECTRICAL PACKAGE INLET AND EXHAUST SYSTEMS FUEL SYSTEMS N.Gas System System, Insulation Blankets, Platforms, Stairs and Ladders Variable Inlet Guide Vane System, Compressor, Bleed System, Purge Air System, Bearing Seal Air System, Combustors, Dual Fuel Nozzles, Turbine Rotor Cooler HVAC, Lighting, and Low Pressure CO2 Fire Protection System HVAC and Lighting, Air Compressor for Pneumatic System, Low Pressure C02 Fire Protection System Lube Oil Reservoir, Accumulators, AC Driven Oil Pumps, DC Emergency Oil Pump with Starter, Oil Coolers, Duplex Oil Filter, Oil Temperature and Pressure Control Valves, Oil Vapor Exhaust Fans and Demister, Oil Heaters, Oil Interconnect Piping (SS and CS), Oil System Instrumentation, Oil for Flushing and First Filling HVAC and Lighting, AC and DC Motor Control Centers, Generator Voltage Regulating Cabinet, Generator Protective Relay Cabinet, DC Distribution Panel, Battery Charger, Digital Control System with Local Control Panel (all control and monitoring functions as well as data logger and sequence of events recorder), Control System Valves and Instrumentation Communication link for interface with plant DCS Supervisory System, Vibration Monitoring System, Low Pressure C02 Fire Protection System, Cable Tray and Conduit Provisions for Performance Testing including Test Ports, Thermowells, Instrumentation and DCS interface cards Inlet Duct Trash Screens, Inlet Duct and Silencers, Self Cleaning Filters, Hoist System For Filter Maintenance, Evaporative Cooler System, Exhaust Duct Expansion Joint, Exhaust Silencers Inlet and Exhaust Flow, Pressure and Temperature Ports and Instrumentation Gas Valves Including Vent, Throttle and Trip Valves, Gas Filter/Separator, Gas Supply Instruments and Instrument Panel STARTING SYSTEM Static Start System, Turning Gear and Clutch Assembly, GENERATOR Static (including excitation transformer), Line Termination Enclosure with CTs, VTs, Surge Arrestors, and Surge Capacitors, Neutral Cubicle with CT, Neutral Tie Bus, Grounding Transformer, and Secondary Resistor, Generator Gas Dryer, Seal Oil System (including Defoaming Tank, Reservoir, Seal Oil Pump, Emergency Seal Oil Pump, Vapor Extractor, and Oil Mist Eliminator), Generator Auxiliaries Control Enclosure, Generator Breaker, Iso-Phase bus connecting generator and breaker, Grounding System Connectors Generator Cooling Hydrogen Cooling System (including H2 to Glycol and Glycol to Air heat exchangers, liquid level detector circulation system, interconnecting piping and controls) MISCELLANEOUS Interconnecting Pipe, Wire, Tubing and Cable Instrument Air System Including Air Dryer On Line and Off Line Water Wash System LP CO2 Storage Tank Drain System Drain Tanks Coupling, Coupling Cover and Associated Hardware March 30, 2009 229

Accessory Electric <strong>Plan</strong>t<br />

Re-powering Study for the Northport <strong>and</strong> Port Jefferson Power Stations<br />

<strong>Appendix</strong> IV Northport <strong>Plan</strong>t Equipment List<br />

Equipment<br />

No.<br />

Description Type<br />

1 CTG<br />

Transformers<br />

2-Oil-filled 290 MVA 18kV/345 kV<br />

2 STG<br />

Transformer<br />

1-Oil-filled 300 MVA 22 kV/345 kV<br />

3 Auxiliary<br />

Transformers<br />

2-Oil-filled 10 MVA 18 kV/4.16 kV<br />

4 Generator<br />

Breaker<br />

2, one for each CT<br />

5 High Side GIS<br />

Breaker<br />

3, one for each CTG <strong>and</strong> one for the STG<br />

6 Low Voltage<br />

Transformer<br />

Dry ventilated 4.16 kV/480V<br />

7 CTG Isolated<br />

Phase Bus<br />

Ducts <strong>and</strong> Tap<br />

Bus<br />

Aluminum, self-cooled 18 kV<br />

8 Medium<br />

Voltage<br />

Switchgear<br />

Metal clad<br />

9 Low Voltage<br />

Switchgear<br />

Instrumentation <strong>and</strong> Control<br />

Metal enclosed<br />

Equipment<br />

No.<br />

Description Type<br />

1 DCS-Main<br />

Control<br />

Monitor/keyboard; Operator printer; Engineering printer<br />

2 DCS-<br />

Processor<br />

Microprocessor with redundant input/output<br />

3 DCS-Data<br />

Highway<br />

Fiber optic<br />

March 30, 2009 228