23.12.2012 Views

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

A<br />

0831 PID-08-07D<br />

FROM FUEL GAS HEATER<br />

1302 PID-13-06B<br />

FROM OXYGEN SCAVENGER<br />

FEED SYSTEM<br />

1301 PID-13-06A<br />

FROM AMINE<br />

FEED SYSTEM<br />

0402 PID-04-01A<br />

CONDENSATE PUMP<br />

DISCHARGE HEADER<br />

REVISION DESCRIPTION<br />

B<br />

APPR<br />

CHECKED<br />

CORRECT<br />

DATE<br />

CNC-V001 CNC-V003<br />

CNC-V002 CNC-V004<br />

CNM<br />

PT<br />

0122<br />

CNM-V030<br />

REVISION DESCRIPTION<br />

C<br />

CNM<br />

CNM<br />

CNM<br />

TE<br />

0123<br />

TW<br />

0123<br />

CNM<br />

CNM<br />

CNM<br />

GLAND<br />

STEAM<br />

CONDENSER<br />

PI<br />

0126<br />

CNM<br />

CNM<br />

CNM<br />

REF. 2<br />

STEAM JET<br />

AIR EJECTOR<br />

CONDENSER<br />

CNM<br />

TW<br />

0128<br />

TW<br />

0127<br />

TE<br />

0127<br />

CNM-V031<br />

TW<br />

0125<br />

TW<br />

0124<br />

TE<br />

0124<br />

TW<br />

0109C<br />

APPR<br />

D<br />

CHECKED<br />

CORRECT<br />

DATE<br />

MKM<br />

CNM<br />

7/2/03<br />

FE<br />

+<br />

0132<br />

REVISION DESCRIPTION<br />

E<br />

CNM<br />

FT<br />

0132<br />

CNM-V032 CNM-V033<br />

APPR<br />

CHECKED<br />

CORRECT<br />

DATE<br />

F<br />

CNM<br />

CNM<br />

TI<br />

0133<br />

TW<br />

0133<br />

CNM<br />

CNM<br />

TE<br />

0135-1<br />

TW<br />

0135-1<br />

CNM<br />

CNM<br />

TE<br />

0135-2<br />

TW<br />

0135-2<br />

REVISION DESCRIPTION<br />

G<br />

CNM-V041<br />

APPR<br />

CHECKED<br />

CORRECT<br />

DATE<br />

CNM<br />

H<br />

PT<br />

0136-1<br />

CNM<br />

CNM-V034A<br />

CNM<br />

CNM<br />

PT<br />

0136-2<br />

CNM-V034B<br />

MKM 10/18/02<br />

MKM<br />

CNM<br />

PT<br />

0136-1<br />

PT<br />

0136-1<br />

FE<br />

+<br />

0139<br />

CNM<br />

CNM-V034A<br />

CNM<br />

CNM-V034A<br />

CNM-V050<br />

CNM<br />

REVISION DESCRIPTION<br />

PT<br />

0136-2<br />

PT<br />

0136-2<br />

FT<br />

0139-1<br />

CNM-V035A CNM-V036A<br />

CNM-V035B<br />

CNM<br />

FT<br />

I<br />

CNM-V034B<br />

0139-2<br />

CNM<br />

CNM-V034B<br />

CNM<br />

FE<br />

CNM-V046<br />

CNM-V022<br />

CNM<br />

FV<br />

+<br />

0132<br />

CNM<br />

FO<br />

CNM-V051<br />

CNM-V037<br />

LV<br />

+<br />

0111-1<br />

FC<br />

CNM-V047<br />

24MAY02<br />

CNM-V053<br />

+ +<br />

0139<br />

FE<br />

CNM<br />

CNM-V035A CNM-V036A<br />

CNM-V035B<br />

CNM<br />

FT<br />

0139-1<br />

FT<br />

0139-2<br />

CNM<br />

CNM-V037<br />

+ +<br />

0139<br />

CNM<br />

APPR<br />

CNM-V035A CNM-V036A<br />

CNM-V035B<br />

CNM<br />

FT<br />

0139-1<br />

FT<br />

0139-2<br />

CHECKED<br />

CORRECT<br />

DATE<br />

J<br />

CNM-V037<br />

LV<br />

+<br />

0137<br />

6"<br />

FC<br />

CNM-V038<br />

CNM-V049<br />

REVISION DESCRIPTION<br />

CNM<br />

CNM<br />

LV<br />

0137<br />

LV<br />

0137<br />

CNM-V040<br />

K L<br />

6"<br />

FC<br />

CNM-V038<br />

6"<br />

FC<br />

CNM-V038<br />

APPR<br />

CHECKED<br />

CORRECT<br />

CNM-V040<br />

CNM-V040<br />

0406 PID-04-01A<br />

MINIMUM FLOW RECIRC TO<br />

CONDENSATE STORAGE TANK<br />

0407<br />

0427 PID-06-01B<br />

TO IP DRUM FILL<br />

0426 PID-06-01B<br />

TO HP DRUM FILL<br />

0405 PID-15-01A<br />

DRAW-OFF TO SERVICE WATER<br />

/ FIRE PROTECTION TANK<br />

0415 PID-11-01A<br />

CONDENSATE SUPPLY TO<br />

STEAM DRAIN SYSTEM<br />

0425 PID-03-03A<br />

HOT REHEAT BYPASS<br />

VALVE SUPPLY<br />

0424 PID-03-04A<br />

LP-BYPASS<br />

VALVE SUPPLY<br />

0417 PID-03-05A<br />

0428 PID-03-12A<br />

TO AUX. STEAM SYSTEM<br />

DESUPERHEATER<br />

TO STEAM TURBINE VACUUM<br />

BREAKER VALVE<br />

HRSG C<br />

LP ECONOMIZER INLET<br />

0414 PID-21-03A<br />

TO SAMPLE PANEL<br />

TO AUX. STEAM DESUPERHEATERS<br />

(MAIN STEAM SYSTEM)<br />

0409 PID-03-02A<br />

TO HRSG 1A & 1B COLD REHEAT DESUPERHEATERS<br />

DATE<br />

0416 PID-11-01A<br />

CONDENSATE SUPPLY TO<br />

STEAM DRAIN SYSTEM<br />

0418 PID-11-01B<br />

CONDENSATE SUPPLY TO<br />

STEAM DRAIN SYSTEM<br />

0429 PID-16-01A<br />

TO GLAND STEAM SKID<br />

EXHAUST HOOD SPRAY<br />

0407<br />

NOTES:<br />

1. FOR GENERAL NOTES, SYMBOLS AND NUMBERING STANDARDS,<br />

LP ECONOMIZER INLET<br />

0427 PID-06-01B<br />

TO IP DRUM FILL<br />

0426 PID-06-01B<br />

0407<br />

HRSG A<br />

TO HP DRUM FILL<br />

HRSG B<br />

LP ECONOMIZER INLET<br />

0427 PID-06-01B<br />

TO IP DRUM FILL<br />

0426 PID-06-01B<br />

TO HP DRUM FILL<br />

M<br />

SEE S&W DRAWINGS 131134-PID-00-01A THRU 00-04A.<br />

CONDENSATE SYSTEM<br />

SHEET 2 OF 2<br />

131134-PID-04-01B-D<br />

NORTHPORT OPTION 9<br />

DESIGNED BY<br />

DSGN CHK’D BY<br />

DRAWING NO.<br />

TM<br />

PIPING & INSTRUMENT<br />

FUNDAMENTAL DIAGRAM<br />

nationalgrid<br />

DRAWN BY<br />

CHK’D BY<br />

CAD MODEL<br />

N<br />

LEVELS<br />

WORK PKG<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

PCT

Hooray! Your file is uploaded and ready to be published.