23.12.2012 Views

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

A<br />

0906 PID-09-09C<br />

CCW SUPPLY HEADER<br />

TO BFP<br />

0911 PID-09-09A<br />

CCW SUPPLY FOR<br />

FUEL GAS COMPRESSOR<br />

REVISION DESCRIPTION<br />

B<br />

APPR<br />

CHECKED<br />

CORRECT<br />

DATE<br />

REVISION DESCRIPTION<br />

C<br />

BOILER FEED<br />

PUMP 1A<br />

APPR<br />

D<br />

CHECKED<br />

CORRECT<br />

DATE<br />

CCW<br />

ZSC<br />

0164A<br />

CCW<br />

FUEL GAS COMPRESSOR<br />

LUBE OIL COOLER 1A<br />

CCW<br />

ZSC<br />

0165A<br />

ZSO<br />

0164A<br />

CCW<br />

CCW<br />

ZSO<br />

0165A<br />

HV<br />

+<br />

0164A<br />

REVISION DESCRIPTION<br />

E<br />

CCW<br />

FO<br />

HV<br />

+<br />

0165A<br />

CCW-V072<br />

FO<br />

CCW<br />

CCW<br />

APPR<br />

PP<br />

0156<br />

PP<br />

0162<br />

CHECKED<br />

CORRECT<br />

DATE<br />

F<br />

CCW-V072<br />

CCW-V077<br />

CCW<br />

CCW<br />

CCW<br />

TI<br />

0163<br />

TW<br />

0163<br />

CCW<br />

HV<br />

+<br />

0165B<br />

REVISION DESCRIPTION<br />

G<br />

HV<br />

FUEL GAS COMPRESSOR<br />

+<br />

0164B<br />

FO<br />

FO<br />

LUBE OIL COOLER 1B<br />

BOILER FEED<br />

PUMP 1B<br />

CCW<br />

CCW-V073<br />

CCW<br />

ZSO<br />

0165B<br />

APPR<br />

ZSO<br />

0164B<br />

CCW<br />

CHECKED<br />

CORRECT<br />

CCW<br />

ZSC<br />

0165B<br />

DATE<br />

ZSC<br />

0164B<br />

H<br />

REVISION DESCRIPTION<br />

CCW<br />

CCW<br />

TI<br />

0157<br />

TW<br />

I<br />

0157<br />

APPR<br />

CHECKED<br />

CORRECT<br />

DATE<br />

J<br />

REVISION DESCRIPTION<br />

K L<br />

APPR<br />

CHECKED<br />

CORRECT<br />

DATE<br />

0907 PID-09-09C<br />

CCW RETURN FROM<br />

BOILER FEED PUMPS<br />

0912 PID-09-09A<br />

CCW RETURN TO<br />

POWERHOUSE<br />

NOTES:<br />

1. FOR GENERAL NOTES, SYMBOLS AND NUMBERING STANDARDS,<br />

SEE S&W DRAWINGS 131134-PID-00-01A THRU 00-04A<br />

2. CCW SUPPLY TO BFP TYPICAL FOR BOTH SETS OF<br />

BOILER FEED PUMPS.<br />

M<br />

COMPONENT COOLING WATER SYSTEM<br />

SHEET 4 OF 4<br />

131134-PID-09-09D-D<br />

NORTHPORT OPTION 4<br />

DESIGNED BY<br />

DSGN CHK’D BY<br />

DRAWING NO.<br />

TM<br />

PIPING & INSTRUMENT<br />

FUNDAMENTAL DIAGRAM<br />

nationalgrid<br />

DRAWN BY<br />

CHK’D BY<br />

CAD MODEL<br />

N<br />

LEVELS<br />

WORK PKG<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

PCT

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!