23.12.2012 Views

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

Appendix E-2.c.i Energy Plan 2004-2013 Follow-up Studies and ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

A<br />

0427 PID-04-01B<br />

FROM CONDENSATE SYSTEM<br />

FOR IP DRUM 1A &1B FILL<br />

0601 PID-06-01A<br />

FROM BOILER FEED PUMP<br />

IP DISCHARGE<br />

0426 PID-04-01B<br />

FROM CONDENSATE SYSTEM<br />

FOR HP DRUM FILL<br />

0602 PID-O6-01A<br />

FROM BOILER FEED PUMP<br />

HP DISCHARGE<br />

REVISION DESCRIPTION<br />

B<br />

APPR<br />

FWS-V029<br />

CHECKED<br />

CORRECT<br />

DATE<br />

FWS-V031<br />

FWS-V064<br />

FWS<br />

TW<br />

0123<br />

FWS-V028<br />

FWS-V066<br />

FWS<br />

FWS<br />

PT<br />

0119<br />

REVISION DESCRIPTION<br />

C<br />

FWS-V022<br />

FWS<br />

FE<br />

FWS-V023A FWS-V024A<br />

TW<br />

0123<br />

FWS<br />

FWS<br />

TW<br />

0130<br />

PT<br />

0119<br />

+<br />

0120<br />

FWS<br />

FWS-V023B FWS-V024B<br />

FWS<br />

FT<br />

0120-1<br />

FT<br />

0120-2<br />

FWS<br />

PT<br />

0131<br />

FWS-V063<br />

FWS<br />

FWS<br />

FWS-V053<br />

FWS-V052<br />

TE<br />

0122-1<br />

TW<br />

0122-1<br />

FWS-V022<br />

FWS<br />

FE<br />

FWS-V023A FWS-V024A<br />

APPR<br />

D<br />

CHECKED<br />

CORRECT<br />

DATE<br />

+<br />

0120<br />

FWS<br />

FWS-V023B FWS-V024B<br />

FWS<br />

FT<br />

0120-1<br />

FT<br />

0120-2<br />

FWS<br />

FWS<br />

FWS<br />

FE<br />

+<br />

0132<br />

TE<br />

0122-2<br />

TW<br />

0122-2<br />

FWS<br />

FWS<br />

REVISION DESCRIPTION<br />

E<br />

TE<br />

0122-1<br />

TW<br />

0122-1<br />

FWS<br />

FT<br />

0132-1<br />

FWS-V055A<br />

FWS-V054A<br />

FWS-V054B<br />

FWS-V055B<br />

FWS<br />

FWS<br />

FWS<br />

FT<br />

0132-2<br />

TE<br />

0122-2<br />

TW<br />

0122-2<br />

FWS<br />

M<br />

FWS-V057A<br />

FWS-V056A<br />

FWS-V056B<br />

FWS-V057B<br />

APPR<br />

MOV<br />

+<br />

0511<br />

CHECKED<br />

CORRECT<br />

DATE<br />

FWS<br />

FWS<br />

F<br />

FWS<br />

M<br />

TE<br />

0133-1<br />

TW<br />

0133-1<br />

MOV<br />

+<br />

0511<br />

FWS<br />

FWS<br />

IP ECONOMIZER<br />

TE<br />

0133-2<br />

TW<br />

0133-2<br />

1A<br />

REVISION DESCRIPTION<br />

G<br />

IP ECONOMIZER<br />

1B<br />

FWS-V050<br />

FWS<br />

APPR<br />

FWS<br />

FWS<br />

FWS<br />

FE<br />

+<br />

0134<br />

CHECKED<br />

CORRECT<br />

FWS<br />

FE<br />

+<br />

0121<br />

FWS<br />

FE<br />

+<br />

0121<br />

FWS<br />

FT<br />

0134<br />

FWS-V033<br />

FWS-V034<br />

DATE<br />

H<br />

FT<br />

0121<br />

FWS-V032 FWS-V033<br />

FT<br />

0121<br />

FWS-V032 FWS-V033<br />

LV<br />

+<br />

0132<br />

FO<br />

FWS-V058<br />

FWS-V035<br />

FWS-V036<br />

REVISION DESCRIPTION<br />

I<br />

FWS-V020<br />

FWS-V020<br />

FWS-V051<br />

FWS<br />

FWS<br />

APPR<br />

LV<br />

+<br />

0120<br />

LV<br />

+<br />

0120<br />

CHECKED<br />

CORRECT<br />

FO<br />

FWS-V026<br />

FO<br />

FWS-V026<br />

DATE<br />

J<br />

FWS-V021<br />

FWS-V021<br />

REVISION DESCRIPTION<br />

K L<br />

0610<br />

TO HRSG IP DRUM 1A<br />

0616 PID-08-07C<br />

TO FUEL GAS HEATER<br />

0610<br />

TO HRSG IP DRUM 1B<br />

0616 PID-08-07C<br />

TO FUEL GAS HEATER<br />

0611<br />

TO REHEATER 1A ATTEMP SPRAY<br />

0611<br />

TO REHEATER 1B ATTEMP APRAY<br />

0612<br />

TO HRSG 1A & 1B HP<br />

0613<br />

1A + 1B<br />

ECONOMIZER INLET<br />

HP SUPERHEATER 1A & 1B<br />

ATTEMP SPRAY<br />

0608 PID-03-01A<br />

MAIN STEAM FEEDWATER BYPASS<br />

VALVE DESUPERHEATER<br />

0608 PID-03-01A<br />

MAIN STEAM TURBINE BYPASS<br />

VALVE DESUPERHEATER SPRAY<br />

APPR<br />

CHECKED<br />

CORRECT<br />

DATE<br />

NOTES:<br />

M<br />

1. FOR GENERAL NOTES, SYMBOLS AND NUMBERING STANDARDS,<br />

SEE S&W DRAWINGS 131134-PID-00-01A THRU 00-04A.<br />

FEEDWATER SYSTEM<br />

SHEET 2<br />

131134-PID-06-01B-D<br />

NORTHPORT OPTION 4<br />

DESIGNED BY<br />

DSGN CHK’D BY<br />

DRAWING NO.<br />

TM<br />

PIPING & INSTRUMENT<br />

FUNDAMENTAL DIAGRAM<br />

nationalgrid<br />

DRAWN BY<br />

CHK’D BY<br />

CAD MODEL<br />

N<br />

LEVELS<br />

WORK PKG<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

PCT

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!