Speedfax 2017
Low-voltage Switchgear Arc Flash Solutions General Other protection options n Infrared Viewing ports n Zone Selective Interlocking n High Resistance Grounding 14 SWITCHGEAR Infrared Viewing Ports Infrared viewing ports allow maintenance personnel to monitor temperatures of the cable and bus connection points in the rear of the gear while it is energized and under load. Excessive temperatures can be an indication of a problem with a connection. Zone Selective Interlocking Zone Selective Interlocking eliminates any intentional time delay in the event a fault occurs between two breakers in adjacent zones. In the schematic to the right, representative time delay values are shown for the breakers in each zone. If a fault occurs on the load side of the downstream breaker, the ZSI system enables the upstream breaker’s delay and allows the downstream device more time to independently clear the fault. If the fault occurs on the line side of the downstream breaker (between two zones), the delay in the upstream breaker will not occur. This allows the fastest tripping time for faults and will reduce the amount of arc energy which may be released. The ZSI function is available for short time delays and ground fault delays. Infrared viewing ports High Resistance Grounding Research has shown that a high percentage of arc faults start as a phase to ground fault. High resistance grounding systems minimize the available phase to ground arcing current. Zone Selective Interlocking A high resistance grounding system reduces the magnitude of phase to ground faults. This will reduce the mechanical stress on equipment for the most common of faults and will reduce the magnitude of energy released. PH1 PH2 PH3 PH1 PH2 NEUT 3-CLF 2-CLF ROD TEST RELAY PULSE RELAY RES RES TEST RELAY PULSE RELAY TEST RESISTOR RES METER RELAY RES SYSTEM SWITCH RES RES SYSTEM SWITCH AM W NORMAL TEST RESISTOR RES METER RELAY RES W NORMAL WIRE LOOP FOR PORTABLE DETECTOR R FAULT AM R FAULT G PULSE WIRE LOOP FOR PORTABLE DETECTOR G PULSE CONTROL CIRCUIT PULSE SW CONTROL CIRCUIT PULSE SW 14-94 Siemens Industry, Inc. SPEEDFAX Product Catalog
Busway Systems SPEEDFAX TM Section Scan to connect online to the most up-todate version of this Section of SPEEDFAX. Sentron connection XJ-L Bus plugs c o n t e n t s Busway Systems Overview General Pricing Notes 15-2 Busway Selector Chart 15-3 Sentron ® Busway Sentron Busway Overview 15-4 – 15-5 Catalog Numbering System 15-6 Technical Data 15-7 – 15-8 Straight Sections – Feeder, Plug-In, & One-Sided Plug-In 15-9 – 15-10 Busway Straight Sections Aluminum & Copper 15-11 Elbows 15-12 – 15-13 Offsets and Combinations 15-14 – 15-15 Tees 15-16 Tap Boxes 15-17 – 15-21 Expansion Fittings 15-22 Reducers and Phase Rotation Fittings 15-23 Service Heads 15-24 Hangers and End Closers 15-25 – 15-27 Roof and Wall/Ceiling/Floor Flanges 15-28 Busway Accessories 15-29 Flanged Ends, Combination Flange/Elbows 15-30 – 15-32 Cubicle Options 15-33 Panelboards and Meter Center Modules 15-34 – 15-35 Installation and Application Information 15-36 Sentron Busway Quick Reference 15-39 Programs and Services 15-37 – 15-41 Sentron Bus Plugs Bus Plug Overview 15-43 Circuit Breaker Bus Plugs 15-44 – 15-49 Fusible Bus Plugs 15-50 – 15-55 SPD Bus Plugs 15-56 – 15-58 3/6 Bus Plugs 15-59 – 15-63 XJ-L TM HD Busway Introduction and Overview 15-64 – 15-65 Busway Specifications 15-66 Straight Sections 15-67 – 15-68 Elbows, Tees and Crosses 15-69 – 15-70 Tap Boxes and Flanges 15-71 – 15-73 Accessories - Hangers & End Closers 15-74 XJ-L HD Bus Plugs Selection Guide and Catalog Numbering System 15-75 XQ and XQR Series 15-76 XPM Series 15-77 XEC and XLEC Series 15-78 XLVB Series and Plug-in Tap Box 15-79 Legacy Products BD ® Plug-In (225 - 1600 Ampere) Copper 15-80 XL-U ® Aluminum (225–5000 Ampere) 15-81 XL-U Copper (225–6500 Amperes) 15-82 XL-X ® , XL-U, BD Plug-In Units 15-83 – 15-84 15 BUSWAY SYSTEMS (Section was last modified on 02/12/20) Siemens Industry, Inc. SPEEDFAX Product Catalog 15-1
- Page 869 and 870: Siemens Unit Substation Solutions O
- Page 871 and 872: Siemens Unit Substation Solutions T
- Page 873 and 874: Siemens Unit Substation Solutions T
- Page 875 and 876: Siemens Unit Substation Solutions I
- Page 877 and 878: Selection and Application Guide | S
- Page 879 and 880: Low-voltage Switchgear Type WL Low-
- Page 881 and 882: Low-voltage Switchgear Type WL Low-
- Page 883 and 884: Low-voltage Switchgear Type WL Low-
- Page 885 and 886: Low-voltage Switchgear Type WL Low
- Page 887 and 888: Low-voltage Switchgear WL Low-volta
- Page 889 and 890: Low-voltage Switchgear WL Low-volta
- Page 891 and 892: Type WL Low Voltage Metal-Enclosed
- Page 893 and 894: Type WL Low Voltage Metal-Enclosed
- Page 895 and 896: Type WL Low Voltage Metal-Enclosed
- Page 897 and 898: Type WL Low Voltage Metal-Enclosed
- Page 899 and 900: (559 m m ) (559 m m Type WL Low ) V
- Page 901 and 902: Type WL Low Voltage Metal-Enclosed
- Page 903 and 904: Type WL Low Voltage Metal-Enclosed
- Page 905 and 906: Type WL Low Voltage Metal-Enclosed
- Page 907 and 908: Switchboard Monitoring Sm@rtGear Mo
- Page 909 and 910: Low-voltage Switchgear Siemens Sm@r
- Page 911 and 912: Low-voltage Switchgear Type WL Low-
- Page 913 and 914: Low-voltage Switchgear Type WL Arc
- Page 915 and 916: Low-voltage Switchgear Arc Flash So
- Page 917 and 918: Low-voltage Switchgear Arc Flash So
- Page 919: Low-voltage Switchgear Arc Flash So
- Page 923 and 924: Busway Systems Overview Busway Sele
- Page 925 and 926: Sentron Busway Systems Sentron Busw
- Page 927 and 928: Sentron Busway Systems Technical Da
- Page 929 and 930: Sentron Busway Systems Straight Sec
- Page 931 and 932: Sentron Straight Section Busway Cop
- Page 933 and 934: Sentron Busway Systems Elbows Revis
- Page 935 and 936: Sentron Busway Systems Revised on 0
- Page 937 and 938: Sentron Busway Systems End Tap Boxe
- Page 939 and 940: NCBA Sentron Busway Systems Joint M
- Page 941 and 942: Sentron Busway Systems TBNK Fitting
- Page 943 and 944: Sentron Busway Systems Reducers and
- Page 945 and 946: Sentron Busway Systems Hangers Revi
- Page 947 and 948: Sentron Busway Systems Hangers and
- Page 949 and 950: Sentron Busway Systems Busway Acces
- Page 951 and 952: Sentron Busway Systems Flanged Ends
- Page 953 and 954: Sentron Busway Systems Cubicle Opti
- Page 955 and 956: Sentron Busway Systems Revised on 0
- Page 957 and 958: Sentron Busway Systems General Info
- Page 959 and 960: Sentron Busway Systems Siemens Sent
- Page 961 and 962: Sentron Busway Systems Programs and
- Page 963 and 964: Sentron Bus Plugs Sentron Bus Plug
- Page 965 and 966: Sentron Bus Plugs Circuit Breaker B
- Page 967 and 968: Sentron Circuit Breaker Bus Plugs B
- Page 969 and 970: Sentron Circuit Breaker Bus Plugs W
Busway Systems<br />
SPEEDFAX TM<br />
Section<br />
Scan to connect<br />
online to the<br />
most up-todate<br />
version of<br />
this Section of<br />
SPEEDFAX.<br />
Sentron connection<br />
XJ-L<br />
Bus plugs<br />
c o n t e n t s<br />
Busway Systems Overview<br />
General Pricing Notes 15-2<br />
Busway Selector Chart 15-3<br />
Sentron ® Busway<br />
Sentron Busway Overview 15-4 – 15-5<br />
Catalog Numbering System 15-6<br />
Technical Data 15-7 – 15-8<br />
Straight Sections – Feeder, Plug-In, & One-Sided Plug-In 15-9 – 15-10<br />
Busway Straight Sections Aluminum & Copper 15-11<br />
Elbows 15-12 – 15-13<br />
Offsets and Combinations 15-14 – 15-15<br />
Tees 15-16<br />
Tap Boxes 15-17 – 15-21<br />
Expansion Fittings 15-22<br />
Reducers and Phase Rotation Fittings 15-23<br />
Service Heads 15-24<br />
Hangers and End Closers 15-25 – 15-27<br />
Roof and Wall/Ceiling/Floor Flanges 15-28<br />
Busway Accessories 15-29<br />
Flanged Ends, Combination Flange/Elbows 15-30 – 15-32<br />
Cubicle Options 15-33<br />
Panelboards and Meter Center Modules 15-34 – 15-35<br />
Installation and Application Information 15-36<br />
Sentron Busway Quick Reference 15-39<br />
Programs and Services 15-37 – 15-41<br />
Sentron Bus Plugs<br />
Bus Plug Overview 15-43<br />
Circuit Breaker Bus Plugs 15-44 – 15-49<br />
Fusible Bus Plugs 15-50 – 15-55<br />
SPD Bus Plugs 15-56 – 15-58<br />
3/6 Bus Plugs 15-59 – 15-63<br />
XJ-L TM HD Busway<br />
Introduction and Overview 15-64 – 15-65<br />
Busway Specifications 15-66<br />
Straight Sections 15-67 – 15-68<br />
Elbows, Tees and Crosses 15-69 – 15-70<br />
Tap Boxes and Flanges 15-71 – 15-73<br />
Accessories - Hangers & End Closers 15-74<br />
XJ-L HD Bus Plugs<br />
Selection Guide and Catalog Numbering System 15-75<br />
XQ and XQR Series 15-76<br />
XPM Series 15-77<br />
XEC and XLEC Series 15-78<br />
XLVB Series and Plug-in Tap Box 15-79<br />
Legacy Products<br />
BD ® Plug-In (225 - 1600 Ampere) Copper 15-80<br />
XL-U ® Aluminum (225–5000 Ampere) 15-81<br />
XL-U Copper (225–6500 Amperes) 15-82<br />
XL-X ® , XL-U, BD Plug-In Units 15-83 – 15-84<br />
15<br />
BUSWAY SYSTEMS<br />
(Section was last modified on 02/12/20)<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog 15-1