Speedfax 2017

12.01.2021 Views

Low-voltage Switchgear Arc Flash Solutions General Other protection options n Infrared Viewing ports n Zone Selective Interlocking n High Resistance Grounding 14 SWITCHGEAR Infrared Viewing Ports Infrared viewing ports allow maintenance personnel to monitor temperatures of the cable and bus connection points in the rear of the gear while it is energized and under load. Excessive temperatures can be an indication of a problem with a connection. Zone Selective Interlocking Zone Selective Interlocking eliminates any intentional time delay in the event a fault occurs between two breakers in adjacent zones. In the schematic to the right, representative time delay values are shown for the breakers in each zone. If a fault occurs on the load side of the downstream breaker, the ZSI system enables the upstream breaker’s delay and allows the downstream device more time to independently clear the fault. If the fault occurs on the line side of the downstream breaker (between two zones), the delay in the upstream breaker will not occur. This allows the fastest tripping time for faults and will reduce the amount of arc energy which may be released. The ZSI function is available for short time delays and ground fault delays. Infrared viewing ports High Resistance Grounding Research has shown that a high percentage of arc faults start as a phase to ground fault. High resistance grounding systems minimize the available phase to ground arcing current. Zone Selective Interlocking A high resistance grounding system reduces the magnitude of phase to ground faults. This will reduce the mechanical stress on equipment for the most common of faults and will reduce the magnitude of energy released. PH1 PH2 PH3 PH1 PH2 NEUT 3-CLF 2-CLF ROD TEST RELAY PULSE RELAY RES RES TEST RELAY PULSE RELAY TEST RESISTOR RES METER RELAY RES SYSTEM SWITCH RES RES SYSTEM SWITCH AM W NORMAL TEST RESISTOR RES METER RELAY RES W NORMAL WIRE LOOP FOR PORTABLE DETECTOR R FAULT AM R FAULT G PULSE WIRE LOOP FOR PORTABLE DETECTOR G PULSE CONTROL CIRCUIT PULSE SW CONTROL CIRCUIT PULSE SW 14-94 Siemens Industry, Inc. SPEEDFAX Product Catalog

Busway Systems SPEEDFAX TM Section Scan to connect online to the most up-todate version of this Section of SPEEDFAX. Sentron connection XJ-L Bus plugs c o n t e n t s Busway Systems Overview General Pricing Notes 15-2 Busway Selector Chart 15-3 Sentron ® Busway Sentron Busway Overview 15-4 – 15-5 Catalog Numbering System 15-6 Technical Data 15-7 – 15-8 Straight Sections – Feeder, Plug-In, & One-Sided Plug-In 15-9 – 15-10 Busway Straight Sections Aluminum & Copper 15-11 Elbows 15-12 – 15-13 Offsets and Combinations 15-14 – 15-15 Tees 15-16 Tap Boxes 15-17 – 15-21 Expansion Fittings 15-22 Reducers and Phase Rotation Fittings 15-23 Service Heads 15-24 Hangers and End Closers 15-25 – 15-27 Roof and Wall/Ceiling/Floor Flanges 15-28 Busway Accessories 15-29 Flanged Ends, Combination Flange/Elbows 15-30 – 15-32 Cubicle Options 15-33 Panelboards and Meter Center Modules 15-34 – 15-35 Installation and Application Information 15-36 Sentron Busway Quick Reference 15-39 Programs and Services 15-37 – 15-41 Sentron Bus Plugs Bus Plug Overview 15-43 Circuit Breaker Bus Plugs 15-44 – 15-49 Fusible Bus Plugs 15-50 – 15-55 SPD Bus Plugs 15-56 – 15-58 3/6 Bus Plugs 15-59 – 15-63 XJ-L TM HD Busway Introduction and Overview 15-64 – 15-65 Busway Specifications 15-66 Straight Sections 15-67 – 15-68 Elbows, Tees and Crosses 15-69 – 15-70 Tap Boxes and Flanges 15-71 – 15-73 Accessories - Hangers & End Closers 15-74 XJ-L HD Bus Plugs Selection Guide and Catalog Numbering System 15-75 XQ and XQR Series 15-76 XPM Series 15-77 XEC and XLEC Series 15-78 XLVB Series and Plug-in Tap Box 15-79 Legacy Products BD ® Plug-In (225 - 1600 Ampere) Copper 15-80 XL-U ® Aluminum (225–5000 Ampere) 15-81 XL-U Copper (225–6500 Amperes) 15-82 XL-X ® , XL-U, BD Plug-In Units 15-83 – 15-84 15 BUSWAY SYSTEMS (Section was last modified on 02/12/20) Siemens Industry, Inc. SPEEDFAX Product Catalog 15-1

Busway Systems<br />

SPEEDFAX TM<br />

Section<br />

Scan to connect<br />

online to the<br />

most up-todate<br />

version of<br />

this Section of<br />

SPEEDFAX.<br />

Sentron connection<br />

XJ-L<br />

Bus plugs<br />

c o n t e n t s<br />

Busway Systems Overview<br />

General Pricing Notes 15-2<br />

Busway Selector Chart 15-3<br />

Sentron ® Busway<br />

Sentron Busway Overview 15-4 – 15-5<br />

Catalog Numbering System 15-6<br />

Technical Data 15-7 – 15-8<br />

Straight Sections – Feeder, Plug-In, & One-Sided Plug-In 15-9 – 15-10<br />

Busway Straight Sections Aluminum & Copper 15-11<br />

Elbows 15-12 – 15-13<br />

Offsets and Combinations 15-14 – 15-15<br />

Tees 15-16<br />

Tap Boxes 15-17 – 15-21<br />

Expansion Fittings 15-22<br />

Reducers and Phase Rotation Fittings 15-23<br />

Service Heads 15-24<br />

Hangers and End Closers 15-25 – 15-27<br />

Roof and Wall/Ceiling/Floor Flanges 15-28<br />

Busway Accessories 15-29<br />

Flanged Ends, Combination Flange/Elbows 15-30 – 15-32<br />

Cubicle Options 15-33<br />

Panelboards and Meter Center Modules 15-34 – 15-35<br />

Installation and Application Information 15-36<br />

Sentron Busway Quick Reference 15-39<br />

Programs and Services 15-37 – 15-41<br />

Sentron Bus Plugs<br />

Bus Plug Overview 15-43<br />

Circuit Breaker Bus Plugs 15-44 – 15-49<br />

Fusible Bus Plugs 15-50 – 15-55<br />

SPD Bus Plugs 15-56 – 15-58<br />

3/6 Bus Plugs 15-59 – 15-63<br />

XJ-L TM HD Busway<br />

Introduction and Overview 15-64 – 15-65<br />

Busway Specifications 15-66<br />

Straight Sections 15-67 – 15-68<br />

Elbows, Tees and Crosses 15-69 – 15-70<br />

Tap Boxes and Flanges 15-71 – 15-73<br />

Accessories - Hangers & End Closers 15-74<br />

XJ-L HD Bus Plugs<br />

Selection Guide and Catalog Numbering System 15-75<br />

XQ and XQR Series 15-76<br />

XPM Series 15-77<br />

XEC and XLEC Series 15-78<br />

XLVB Series and Plug-in Tap Box 15-79<br />

Legacy Products<br />

BD ® Plug-In (225 - 1600 Ampere) Copper 15-80<br />

XL-U ® Aluminum (225–5000 Ampere) 15-81<br />

XL-U Copper (225–6500 Amperes) 15-82<br />

XL-X ® , XL-U, BD Plug-In Units 15-83 – 15-84<br />

15<br />

BUSWAY SYSTEMS<br />

(Section was last modified on 02/12/20)<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 15-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!