Type WL Low Voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Low-voltage Switchgear<br />

WL Low-voltage Metal-Enclosed Switchgear<br />

Dimensional Information<br />

Indoor Floor Plan and Cable Space Details<br />

1.25<br />

(32)<br />

typ.<br />

.86<br />

(22)<br />

4.42 (112)<br />

.75 (19) typ.<br />

.75 (19) typ.<br />

1.50<br />

(38)<br />

.86<br />

(22)<br />

5.86<br />

(149) 7.88 1<br />

(200)<br />

Note<br />

3<br />

4.82<br />

(122)<br />

B<br />

Transformer<br />

Throat<br />

4.00<br />

(102)<br />

14<br />

SWITCHGEAR<br />

A<br />

Liquid filled &<br />

outdoor dry type<br />

transformers only<br />

C L<br />

14.9<br />

(378)<br />

Maximum available<br />

space in top or bottom<br />

of unit for customer's<br />

power cables<br />

(4) Holes for<br />

.50 (12mm)<br />

Grade 5<br />

anchor bolts<br />

Space for<br />

secondary<br />

leads from<br />

above<br />

2.00 (51)<br />

5.00<br />

(127)<br />

4.00 2<br />

(102)<br />

1.00<br />

(25)<br />

2.12<br />

(54)<br />

End Trim Panel (typ.)<br />

Required on left and<br />

right end of switchboard<br />

lineup — adds 2”<br />

to total lineup width<br />

3.00 (76)<br />

D<br />

Space for<br />

secondary<br />

leads from<br />

below<br />

7.00<br />

(179)<br />

C<br />

2.37 (60)<br />

Note 4<br />

1.00 (25) W<br />

W = 22 (559) or 32 (813)<br />

1.00 (25)<br />

2.00 (51)<br />

4.40 (112)<br />

A B C D<br />

Equipment Depth<br />

Direction of Cables<br />

60” Non-Fused with<br />

1 2<br />

(N, S, H or L-Class Breakers) Below 21.50 (546)<br />

13.88 (353) 32.59 (828)<br />

OR<br />

Above 21.25 (540) 1 18.88 (480) 37.59 (955)<br />

65” Fused with (F-Class Breakers)<br />

70” Non-fused with<br />

(N, S, H or L-Class Breakers)<br />

Below 31.50 (800) 1 2 13.88 (353) 32.59 (828)<br />

OR<br />

75” Fused with (F-Class Breakers) Above 31.25 (794) 1 18.88 (480) 37.59 (955)<br />

80” Non-fused with Below 41.50 (1054) 1 2<br />

(N, S, H or L-Class Breakers) Above 41.25 (1048) 1<br />

13.88 (353) 32.59 (828)<br />

80” Fused with Below 36.50 (927) 1 2<br />

(F-Class Breakers) Above 36.25 (921) 1<br />

18.88 (480) 37.59 (955)<br />

Note: Dimensions shown in inches and (mm).<br />

1 Reduce by 7.88” if upper neutral is present with cables above or if a lower neutral is present with cables below.<br />

2 Reduce by 4.00” if an 800-3200A breaker is located in the bottom compartment.<br />

Reductions per notes 1 & 2 are additive. Example: cables below + lower neutral + 2000A breaker in bottom compartment = B-11.88.<br />

3 Reduce cable space by 4.00” x 4.82” if Neutral Riser is present. (Consult Factory).<br />

4 4.10 (104) if W=22; 4.60 (117) if W=32.<br />

27<br />

14-76<br />