Medium-voltage Equipment<br />

SIMOVAC-AR medium-voltage controller<br />

General<br />

Arc-resistant, up to 720 A, and 2.4 kV, 4.16 kV and 6.9 kV<br />

Description<br />

A leader in the design of mediumvoltage<br />

controllers, Siemens offers its<br />

advanced arc-resistant medium-voltage<br />

controller with enhanced safety for<br />

your personnel. Siemens combined its<br />

knowledge as a leading manufacturer of<br />

motors worldwide and as a world-class<br />

supplier of medium-voltage controller<br />

innovation and technologies to deliver<br />

flexibility and reliability.<br />

Featuress and benefits<br />

n Tested for arc-resistance to IEEE<br />

C37.20.7-2007, up to 63 kA, 0.5 s,<br />

accessibility type 2B<br />

n UL 347 5th edition/CSA C22.2 No.<br />

253-09<br />

n 400 A bolt-in or plug-in (optional) or<br />

720 A bolt-in vacuum contactor<br />

n 400 A or 720 A non-load-break<br />

isolation switch<br />

n 2.4 kV, 4.16 kV and 6.9 kV (up to 7.65<br />

kV) system voltage ratings<br />

n 1,200 A, 2,000 A, 3,000 A or 4,000<br />

A main bus with standard epoxy<br />

insulation on bus bars, and with<br />

optional boots for insulating joints<br />

n Tin- or silver-plated bus available<br />

n Front accessible<br />

n Main bus and ground bus are<br />

supported and braced up to 63 kA<br />

two-second short-time capability<br />

n Top-mounted pressure relief channel<br />

shipped installed for reduced site<br />

installation time<br />

n Isolation switch with visible indication<br />

through viewing window to verify that<br />

the power cell is isolated from lineside<br />

source – no need to open panel<br />

door<br />

n Isolation switch mechanically<br />

interlocked with the access door<br />

to prevent user access to primary<br />

compartment when isolation switch is<br />

closed<br />

n Low-voltage compartment is<br />

isolated from the medium-voltage<br />

compartment<br />

n All components are front accessible,<br />

facilitating routine inspection or parts<br />

replacement<br />

n Current-limiting fuses, contactor<br />

assembly and isolating switch<br />

assembly are easily removed from<br />

the enclosure<br />

n The main bus compartment is top,<br />

side and front accessible for easy<br />

installation and extension.<br />

14 SWITCHGEAR<br />