Medium-voltage Equipment<br />

Types GM-SG and GM-SG-AR<br />

Stacking Versatility<br />

Stacking versatility continued<br />

GM-SG-AR arc-resistant 63 kA -<br />

1,200 A<br />

circuit<br />

breaker<br />

1,200 A<br />

circuit<br />

breaker<br />

Auxiliary<br />

1,200 A<br />

circuit<br />

breaker<br />

2,000 A<br />

circuit<br />

breaker<br />

2,000 A<br />

circuit<br />

breaker<br />

A<br />

A<br />

D<br />

A<br />

A<br />

A<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

Auxiliary<br />

B<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

2,000 A<br />

circuit<br />

breaker<br />

B<br />

1,200 A<br />

circuit<br />

breaker<br />

B<br />

2,000 A<br />

circuit<br />

breaker<br />

B<br />

14 SWITCHGEAR<br />

Auxiliary<br />

2,000 A<br />

circuit<br />

breaker<br />

Vented 7<br />

Fan 7<br />

Auxiliary<br />

D<br />

A<br />

A<br />

A<br />

A<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

Low-voltage<br />

panel<br />

2,000 A<br />

circuit<br />

breaker<br />

Auxiliary<br />

3,000 A 7<br />

circuit<br />

breaker<br />

3,000 A 7<br />

circuit<br />

breaker<br />

Auxiliary<br />

B<br />

B<br />

B<br />

B<br />

B<br />

Footnotes for GM-SG-AR arc-resistant 63 kA:<br />

1. Main bus sizes 1,200 A, 2,000 A, 3,000 A or 4,000 A (self-cooled).<br />

No rollout auxiliaries allowed in upper cell (A) if lower cell (B) has 3,000 A circuit breaker.<br />

Auxiliary cells (A or B) may each contain one rollout (except as indicated in Footnotes 2 and 7).<br />

Fuse rollout for stationary CPT must be located in lower rollout cell B, if CPT is located in rear or is remote.<br />

Stacking arrangements are available as shown for arc-resistant type GM-SG-AR equipment rated 63 kA. Total circuit breaker loading in a vertical unit may not exceed main bus rating.<br />

Consult Siemens for specific application assistance regarding total load limits in each unit or refer to ANSI/IEEE C37.20.2.<br />

Generator circuit breakers (type GMSG-GCB) conform to same stacking rules as standard (nongenerator) circuit breakers.<br />

For fan-cooled 4,000 A rating, circuit breaker (3,000 A self-cooled, 4,000 A fan-cooled) may be located in lower cell (B) with fan cooling in cell A.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 14-11