Speedfax 2017
Distribution Switchboards Type SB1, SB2 and SB3 Revised on 05/15/18 General Individual Product lines SB1 Switchboards Siemens SB1 switchboards have been specifically designed for the shortest lead times and for applications where floor space is at a premium. The rear of all sections align so the switchboard can be installed against a wall. SB1 switchboards can contain main and branch protective devices and through bus ratings up to 2000 amperes and 600 Volts AC. SB3 Switchboards Siemens SB3 switchboards are designed for custom options. SB3 switchboards can incorporate custom busway & transformer connections, rear access, all types of utility metering provisions and many other options. No matter your need, Siemens SB3 switchboards can provide a solution. 13 SWITCHBOARDS SB2 Switchboards Siemens SB2 switchboards have been designed to be able to incorporate additional features. SB2 switchboards can have extra depth behind the bussing in each distribution section, can be front and rear aligned and can handle up to 4000 amperes and 600 Volts AC. These switchboards may also include insulated case circuit breakers, solid state molded case circuit breakers and density rated bussing. SB1 Switchboards Available Features Device Usage Device Type Ampere Rating Mounting • Individual or panel mounted mains • Individual or panel mounted branches • Thermal magnetic MCCBs • 2000A maximum main bus • Front accessible • Rear Aligned • Standard Utility Metering Position • Customer metering: digital & analog meters • 65KAIC interruption rating • 65C Copper and Aluminum bussing • Type 1 and 3R enclosures • Integrated lighting panelboards Main Branch Molded Case Circuit Breakers (MCCB) Molded Case Circuit Breakers (MCCB) Vacu-Break Switches (VBS) Vacu-Break Switches (VBS) High Contact Pressure Switches (HCP) Bolted Pressure Switches (BPS) Molded Case Circuit Breakers (MCCB) Molded Case Circuit Breakers (MCCB) Vacu-Break Switches (VBS) Vacu-Break Switches (VBS) High Contact Pressure Switches (HCP) Bolted Pressure Switches (BPS) 400 - 1200 400 - 2000 400 - 600 800 - 1200 800 - 1200 800 - 2000 15 - 1200 400 - 2000 30 - 600 800 - 1200 400 - 1200 800 - 1200 Panel Individual Panel Individual Individual Individual Panel Individual Panel Individual Individual Individual SB2 Switchboards Available Features Device Usage Device Type Ampere Rating Mounting • All SB1 options • 4000A maximum main bus • Electronic trip unit (solid state) MCCBs • Density rated copper and aluminum bussing • 100KAIC interruption rating • Standard Maintenance Mode DAS (Dynamic Arc Sentry) Main Branch All SB1 main devices Bolted Pressure Switches (BPS) WL Insulated Case Circuit Breakers (WL) All SB1 branch devices Bolted Pressure Switches (BPS) WL Insulated Case Circuit Breakers (WL) Up to 4000 Up to 4000 Up to 4000 Up to 4000 Individual Individual Individual Individual SB3 Switchboards Available Features Device Usage Device Type Ampere Rating Mounting • All SB1 & SB2 options • 6000A maximum main bus • 200KAIC interruption rating • Rear accessible • Custom busway and transformer connections • Additional special options and configurations Main Branch All SB1 & SB2 main devices Bolted Pressure Switches (BPS) WL Insulated Case Circuit Breakers (WL) All SB1 & SB2 branch devices Bolted Pressure Switches (BPS) WL Insulated Case Circuit Breakers (WL) Up to 6000 Up to 5000 Up to 6000 Up to 5000 Individual Individual Individual Individual 13-4 Siemens Industry, Inc. SPEEDFAX Product Catalog
Integrated Power Systems Switchboards Type IPS General Product Description Siemens integrated power systems (IPS) switchboards integrate multiple pieces of electrical distribution equipment into a single assembly. The design results in reduced installation time, a reduced footprint and reduced labor risk for installation. The modular design of the IPS switchboard allows it to be combined with standard service entrance or distribution switchboards if needed. Also, the IPS switchboard can be added to an existing switchboard lineup. IPS switchboards have a wide range of applications and are commonly used in retail stores, offices, health care facilities and retrofits. Features & Benefits Integrated Power Systems Switchboard Commonly Mounted Equipment Features n All standard SB1, SB2 & SB3 switchboard features n Lighting panelboards n Distribution transformers n Half high distribution switchboard chassis n Individually mounted breakers (cable in & cable out) n Auxiliary sections for surge devices, ACCESS power monitoring, contactors, relays, time clocks, motor starters, customer equipment, etc. 13 SWITCHBOARDS 1 Distribution sections n Up to 3000A (full height) n Up to 1200A (half height) 3 2 Transformers n Up to 300KVA (full height) n Up to 150KVA (half height) 1 2 3 Panelboards n Up to 800A (full height) n Up to 600A (half height) Siemens Industry, Inc. SPEEDFAX Product Catalog 13-5
- Page 753 and 754: 3VA Breaker Configuration Informati
- Page 755 and 756: Panelboards Type P4 Panelboards Dim
- Page 757 and 758: Panelboards Power and Distribution
- Page 759 and 760: Panelboards Power and Distribution
- Page 761 and 762: Panelboards Power and Distribution
- Page 763 and 764: Panelboards Embedded Micro Metering
- Page 765 and 766: Panelboards Modifications and Addit
- Page 767 and 768: Panelboards Type P4 Panelboards Rev
- Page 769 and 770: Panelboards Power and Distribution
- Page 771 and 772: Panelboards Power and Distribution
- Page 773 and 774: Panelboards Power and Distribution
- Page 775 and 776: Panelboards Power and Distribution
- Page 777 and 778: Panelboards Embedded Micro Metering
- Page 779 and 780: Panelboards Modifications and Addit
- Page 781 and 782: Panelboards Type P5 Panelboards Rev
- Page 783 and 784: Panelboards Circuit Breaker / Colum
- Page 785 and 786: Panelboards Circuit Breaker / Colum
- Page 787 and 788: Panelboards Enclosure Modifications
- Page 789 and 790: Panelboards Circuit Breaker Accesso
- Page 791 and 792: Panelboards Quik-Spec Coordination
- Page 793 and 794: Panelboards SCCPB Branch Disconnect
- Page 795 and 796: Panelboards Dimensions and Panelboa
- Page 797 and 798: Panelboards Fuse Curves Time-Curren
- Page 799 and 800: Lighting Controls SPEEDFAX TM Secti
- Page 801 and 802: Switchboards SPEEDFAX TM Section Fr
- Page 803: Distribution Switchboards Type SB1,
- Page 807 and 808: Commercial Multi-Metering Switchboa
- Page 809 and 810: Switchboards Revised on 04/14/17 Sm
- Page 811 and 812: Generator Ready Switchboards Type G
- Page 813 and 814: Rear Connected Switchboards Type RC
- Page 815 and 816: Stock Service Entrance Switchboards
- Page 817 and 818: Stock Service Entrance Switchboards
- Page 819 and 820: Stock Service Entrance Switchboards
- Page 821 and 822: Stock Service Entrance Switchboards
- Page 823 and 824: Switchboard Monitoring Sm@rtGear Mo
- Page 825 and 826: Switchboard Replacement Parts & Mod
- Page 827 and 828: Switchgear SPEEDFAX TM Section Type
- Page 829 and 830: Medium-voltage Equipment 5 - 15 kV
- Page 831 and 832: Medium-voltage Equipment Medium-vol
- Page 833 and 834: Medium-voltage Equipment Type GMSG
- Page 835 and 836: Medium-voltage Equipment Types GM-S
- Page 837 and 838: Medium-voltage Equipment Types GM-S
- Page 839 and 840: Medium-voltage Equipment GM-SG Acce
- Page 841 and 842: Medium-voltage Equipment Type GM-SG
- Page 843 and 844: Medium-voltage Equipment 38 kV Type
- Page 845 and 846: Medium-voltage Equipment 38 kV Gas-
- Page 847 and 848: Medium-voltage Equipment 5 - 15 kV
- Page 849 and 850: Medium-voltage Equipment SIMOVAC-AR
- Page 851 and 852: Medium-voltage Equipment SIMOVAC Co
- Page 853 and 854: Protective Relays & SCADA Systems S
Distribution Switchboards<br />
Type SB1, SB2 and SB3<br />
Revised on 05/15/18<br />
General<br />
Individual Product lines<br />
SB1 Switchboards<br />
Siemens SB1 switchboards have been specifically designed<br />
for the shortest lead times and for applications where floor<br />
space is at a premium. The rear of all sections align so the<br />
switchboard can be installed against a wall. SB1 switchboards<br />
can contain main and branch protective devices and through<br />
bus ratings up to 2000 amperes and 600 Volts AC.<br />
SB3 Switchboards<br />
Siemens SB3 switchboards are designed for custom<br />
options. SB3 switchboards can incorporate custom busway<br />
& transformer connections, rear access, all types of utility<br />
metering provisions and many other options. No matter your<br />
need, Siemens SB3 switchboards can provide a solution.<br />
13<br />
SWITCHBOARDS<br />
SB2 Switchboards<br />
Siemens SB2 switchboards have been designed to be able to<br />
incorporate additional features. SB2 switchboards can have<br />
extra depth behind the bussing in each distribution section,<br />
can be front and rear aligned and can handle up to 4000<br />
amperes and 600 Volts AC. These switchboards may also<br />
include insulated case circuit breakers, solid state molded<br />
case circuit breakers and density rated bussing.<br />
SB1 Switchboards<br />
Available Features<br />
Device<br />
Usage<br />
Device Type<br />
Ampere<br />
Rating<br />
Mounting<br />
• Individual or panel mounted mains<br />
• Individual or panel mounted branches<br />
• Thermal magnetic MCCBs<br />
• 2000A maximum main bus<br />
• Front accessible<br />
• Rear Aligned<br />
• Standard Utility Metering Position<br />
• Customer metering: digital & analog meters<br />
• 65KAIC interruption rating<br />
• 65C Copper and Aluminum bussing<br />
• Type 1 and 3R enclosures<br />
• Integrated lighting panelboards<br />
Main<br />
Branch<br />
Molded Case Circuit Breakers (MCCB)<br />
Molded Case Circuit Breakers (MCCB)<br />
Vacu-Break Switches (VBS)<br />
Vacu-Break Switches (VBS)<br />
High Contact Pressure Switches (HCP)<br />
Bolted Pressure Switches (BPS)<br />
Molded Case Circuit Breakers (MCCB)<br />
Molded Case Circuit Breakers (MCCB)<br />
Vacu-Break Switches (VBS)<br />
Vacu-Break Switches (VBS)<br />
High Contact Pressure Switches (HCP)<br />
Bolted Pressure Switches (BPS)<br />
400 - 1200<br />
400 - 2000<br />
400 - 600<br />
800 - 1200<br />
800 - 1200<br />
800 - 2000<br />
15 - 1200<br />
400 - 2000<br />
30 - 600<br />
800 - 1200<br />
400 - 1200<br />
800 - 1200<br />
Panel<br />
Individual<br />
Panel<br />
Individual<br />
Individual<br />
Individual<br />
Panel<br />
Individual<br />
Panel<br />
Individual<br />
Individual<br />
Individual<br />
SB2 Switchboards<br />
Available Features<br />
Device<br />
Usage<br />
Device Type<br />
Ampere<br />
Rating<br />
Mounting<br />
• All SB1 options<br />
• 4000A maximum main bus<br />
• Electronic trip unit (solid state) MCCBs<br />
• Density rated copper and aluminum bussing<br />
• 100KAIC interruption rating<br />
• Standard Maintenance Mode DAS (Dynamic Arc Sentry)<br />
Main<br />
Branch<br />
All SB1 main devices<br />
Bolted Pressure Switches (BPS)<br />
WL Insulated Case Circuit Breakers (WL)<br />
All SB1 branch devices<br />
Bolted Pressure Switches (BPS)<br />
WL Insulated Case Circuit Breakers (WL)<br />
Up to 4000<br />
Up to 4000<br />
Up to 4000<br />
Up to 4000<br />
Individual<br />
Individual<br />
Individual<br />
Individual<br />
SB3 Switchboards<br />
Available Features<br />
Device<br />
Usage<br />
Device Type<br />
Ampere<br />
Rating<br />
Mounting<br />
• All SB1 & SB2 options<br />
• 6000A maximum main bus<br />
• 200KAIC interruption rating<br />
• Rear accessible<br />
• Custom busway and transformer connections<br />
• Additional special options and configurations<br />
Main<br />
Branch<br />
All SB1 & SB2 main devices<br />
Bolted Pressure Switches (BPS)<br />
WL Insulated Case Circuit Breakers (WL)<br />
All SB1 & SB2 branch devices<br />
Bolted Pressure Switches (BPS)<br />
WL Insulated Case Circuit Breakers (WL)<br />
Up to 6000<br />
Up to 5000<br />
Up to 6000<br />
Up to 5000<br />
Individual<br />
Individual<br />
Individual<br />
Individual<br />
13-4<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog