Panelboards<br />

Circuit Breaker / Column Type<br />

Revised on 05/15/18<br />

Selection<br />

Main Lugs Only C1<br />

Maximum<br />

Panel<br />

Ampere Rating<br />

Maximum<br />

1-Pole<br />

Circuits<br />

Box<br />

Height<br />

(inches)<br />

240 Volts Maximum<br />

208Y/120V 120/240V<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

1-Phase, 3-Wire<br />

Catalog Number<br />

18 48 C1C18ML125CTS C1A18ML125CTS<br />

125<br />

30 73 C1C30ML125CTS C1A30ML125CTS<br />

42 85 C1C42ML125CTS C1A42ML125CTS<br />

18 48 C1C18ML250CTS C1A18ML250CTS<br />

250<br />

30 73 C1C30ML250CTS C1A30ML250CTS<br />

42 85 C1C42ML250CTS C1A42ML250CTS<br />

Main Circuit Breaker ab C1<br />

240 Volts Maximum<br />

18 48 C1C18BL100CTS C1A18BL100CTS<br />

100<br />

30 73 C1C30BL100CTS C1A30BL100CTS<br />

42 85 C1C42BL100CTS C1A42BL100CTS<br />

18 48 C1C18E4125CTS C1A18E4125CTS<br />

125<br />

30 73 C1C30E4125CTS C1A30E4125CTS<br />

42 85 C1C42E4125CTS C1A42E4125CTS<br />

18 48 C1C18QR225CTS C1A18QR225CTS<br />

225<br />

30 73 C1C30QR225CTS C1A30QR225CTS<br />

42 85 C1C42QR225CTS C1A42QR225CTS<br />

18 48 C1C18FX250CTS C1A18FX250CTS<br />

250<br />

30 73 C1C30FX250CTS C1A30FX250CTS<br />

42 85 C1C42FX250CTS C1A42FX250CTS<br />

11 PANELBOARDS<br />

Main Lugs Only C2<br />

Maximum<br />

Panel<br />

Ampere Rating<br />

Maximum<br />

1-Pole<br />

Circuits<br />

Box<br />

Height<br />

(inches)<br />

480Y/277 Volts Maximum<br />

480Y/277V<br />

3-Phase, 4-Wire<br />

Catalog Number<br />

18 48 C2E18ML125CTS<br />

125<br />

30 73 C2E30ML125CTS<br />

42 85 C2E42ML125CTS<br />

18 48 C2E18ML250CTS<br />

250<br />

30 73 C2E30ML250CTS<br />

42 85 C2E42ML250CTS<br />

Main Circuit Breaker ab C2<br />

480Y/277 Volts Maximum<br />

18 48 C2E18BD100CTS<br />

100<br />

30 73 C2E30BD100CTS<br />

42 85 C2E42BD100CTS<br />

18 48 C2E18E4125CTS<br />

125<br />

30 73 C2E30E4125CTS<br />

42 85 C2E42E4125CTS<br />

18 48 C2E18FX225CTS<br />

225<br />

30 73 C2E30FX225CTS<br />

42 85 C2E42FX225CTS<br />

18 48 C2E18FX250CTS<br />

250<br />

30 73 C2E30FX250CTS<br />

42 85 C2E42FX250CTS<br />

Alternate Main Breaker Selection ab C1<br />

Ampere<br />

Rating<br />

Breaker<br />

Type<br />

Maximum<br />

Interrupting<br />

Rating (KA)<br />

Catalog<br />

Number<br />

Available Trip Values<br />

BL 10 BL 50, 60, 70, 80, 90, 100<br />

100<br />

BLH 22 LH 50, 60, 70, 80, 90, 100<br />

HBL 65 HL 50, 60, 70, 80, 90, 100<br />

125<br />

ED4 65 E4 50, 60, 70, 80, 90, 100, 110, 125<br />

HED4 100 H4 50, 60, 70, 80, 90, 100, 110, 125<br />

HHED6 100 HA 50 (3-pole only)<br />

225 QR2 10 QR 100, 110, 125, 150, 175, 200, 225<br />

225<br />

FXD6 65 FX 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

HFD6 b 100 HF 70, 80, 90, 100, 110, 125, 150, 175, 200, 225<br />

250<br />

FXD6 65 FX 250<br />

HFD6 b 100 HF 250<br />

For inches / millimeters conversion,<br />

see Application Data section.<br />

a BL, BLH, HBL and BQD are horizontally mounted.<br />

All others vertically mounted.<br />

b Interchangeable trip breakers such as FD6 and HFD6<br />

cannot be back fed. Must be top feed only.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-99