3VA Breaker Configuration Information in Panelboards<br />

Revised on 04/30/19<br />

3VA52 Breakers – 2 Pole and 3 Pole<br />

Selection<br />

3VA52 2 and 3 Pole Breakers<br />

3VA52 TMTU 250A max.<br />

n Part numbers shown are without Lugs.<br />

n Standard Lug kits used in Panelboards are shown in tables below.<br />

TMTU<br />

frame<br />

Type<br />

kA<br />

code<br />

Type<br />

ref<br />

MB<br />

code<br />

3VA52 MFAS M FAS VA<br />

3VA52 HFAS H FAS VB<br />

3VA52 CFAS C FAS VC<br />

11 PANELBOARDS<br />

3VA52<br />

3-Pole Description<br />

3 Pole 3VA52 without connectors<br />

The default for Panelboard in COMPAS will be AL 1-conductor connectors:<br />

for AL order one 3VA9233-0JB12 (accepts (1) #6 AWG-350kcmil AL/CU conductor)<br />

for CU order one 3VA9233-0JD12 (accepts (1) #6 AWG-350kcmil CU only conductor)<br />

UL Type Code ==> MFAS HFAS CFAS<br />

Panelboard MB codes ==> VA VB VC<br />

Ratings 3-pole | 2-pole 3-pole | 2-pole 3-pole | 2-pole<br />

240 VAC kAIC rating ==> 85 | 85 100 | 100 200 a | 200 a<br />

480Y / 277 VAC kAIC rating ==> 35 | 35 65 | 65 100 | 100<br />

480 VAC kAIC rating ==> 35 | 35 65 | 65 100 | 100<br />

600Y / 347 VAC kAIC rating ==> 18 | 18 25 | 25 35 | 35<br />

600 VAC kAIC rating ==> 18 | 18 25 | 25 35 | 35<br />

250 VDC kAIC rating ==> na | 50 na | 85 na | 100<br />

IC family @ 480 VAC ==> 35kA 65kA 100kA<br />

FTAM Trip included ==> TM230 TM230 TM230<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

3-pole 3-pole 3-pole<br />

100 10 3VA52 3P breaker w/TM230 3VA5210-5EC31-0AA0 3VA5210-6EC31-0AA0 3VA5210-7EC31-0AA0<br />

110 11 3VA52 3P breaker w/TM230 3VA5211-5EC31-0AA0 3VA5211-6EC31-0AA0 3VA5211-7EC31-0AA0<br />

125 12 3VA52 3P breaker w/TM230 3VA5212-5EC31-0AA0 3VA5212-6EC31-0AA0 3VA5212-7EC31-0AA0<br />

150 15 3VA52 3P breaker w/TM230 3VA5215-5EC31-0AA0 3VA5215-6EC31-0AA0 3VA5215-7EC31-0AA0<br />

175 17 3VA52 3P breaker w/TM230 3VA5217-5EC31-0AA0 3VA5217-6EC31-0AA0 3VA5217-7EC31-0AA0<br />

200 20 3VA52 3P breaker w/TM230 3VA5220-5EC31-0AA0 3VA5220-6EC31-0AA0 3VA5220-7EC31-0AA0<br />

225 22 3VA52 3P breaker w/TM230 3VA5222-5EC31-0AA0 3VA5222-6EC31-0AA0 3VA5222-7EC31-0AA0<br />

250 25 3VA52 3P breaker w/TM230 3VA5225-5EC31-0AA0 3VA5225-6EC31-0AA0 3VA5225-7EC31-0AA0<br />

Molded Case Switch HFAS CFAS<br />

100 10 3VA52 3P MCS 100kA na na 3VA5210-1BB31-0AA0<br />

150 15 3VA52 3P MCS 65kA/100kA na 3VA5215-0BB31-0AA0 3VA5215-1BB31-0AA0<br />

250 25 3VA52 3P MCS 65kA/100kA na 3VA5225-0BB31-0AA0 3VA5225-1BB31-0AA0<br />

3VA52<br />

2-Pole Description<br />

2 Pole 3VA52 (in 3-Pole frame) without connectors<br />

The default for Panelboard in COMPAS will be AL 1-conductor connectors:<br />

for AL order one 3VA9233-0JB12 (accepts (1) #6 AWG-350kcmil AL/CU conductor)<br />

for CU order one 3VA9233-0JD12 (accepts (1) #6 AWG-350kcmil CU only conductor)<br />

Catalog Number Catalog Number Catalog Number<br />

Amps Code Description<br />

2-pole 2-pole 2-pole<br />

100 10 3VA52 2P breaker w/TM230 3VA5210-5EC61-0AA0 3VA5210-6EC61-0AA0 3VA5210-7EC61-0AA0<br />

110 11 3VA52 2P breaker w/TM230 3VA5211-5EC61-0AA0 3VA5211-6EC61-0AA0 3VA5211-7EC61-0AA0<br />

125 12 3VA52 2P breaker w/TM230 3VA5212-5EC61-0AA0 3VA5212-6EC61-0AA0 3VA5212-7EC61-0AA0<br />

150 15 3VA52 2P breaker w/TM230 3VA5215-5EC61-0AA0 3VA5215-6EC61-0AA0 3VA5215-7EC61-0AA0<br />

175 17 3VA52 2P breaker w/TM230 3VA5217-5EC61-0AA0 3VA5217-6EC61-0AA0 3VA5217-7EC61-0AA0<br />

200 20 3VA52 2P breaker w/TM230 3VA5220-5EC61-0AA0 3VA5220-6EC61-0AA0 3VA5220-7EC61-0AA0<br />

225 22 3VA52 2P breaker w/TM230 3VA5222-5EC61-0AA0 3VA5222-6EC61-0AA0 3VA5222-7EC61-0AA0<br />

250 25 3VA52 2P breaker w/TM230 3VA5225-5EC61-0AA0 3VA5225-6EC61-0AA0 3VA5225-7EC61-0AA0<br />

Molded Case Switch HFAS CFAS<br />

100 10 3VA52 2P MCS 100kA na na 3VA5210-1BB61-0AA0<br />

150 15 3VA52 2P MCS 65kA/100kA na 3VA5215-0BB61-0AA0 3VA5215-1BB61-0AA0<br />

250 25 3VA52 2P MCS 65kA/100kA na 3VA5225-0BB61-0AA0 3VA5225-1BB61-0AA0<br />

a Although some breakers have a kAIC rating above 100<br />

kAIC – many panels are limited to 100 kAIC or less.<br />

b DC Voltage panels are limited by various factors.<br />

These DC ratings apply to the Breaker only.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-63