3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA Electronic Trip Units — 100% Rated<br />

Selection<br />

11<br />

PANELBOARDS<br />

3VA6 100% rated ETU – "Electronic Trip" versions of 3VA Breakers in Panelboards<br />

n See following pages for internal accessory pocket locations available in TMTU & ETU versions<br />

n Breakers shown do not include lugs - lugs are ordered separately as needed per application<br />

n COMPAS will allow various Lug configurations based on Panel Type and mounting location<br />

For Accessories<br />

and positions see<br />

tables on pages<br />

11-64 and 11-68<br />

Connector Kits for 3 Pole 3VA6 series Breakers – 100% rated (Requires CU Connectors)<br />

Description<br />

note: Use 3-pole for<br />

2-pole applications<br />

Connector Kits AL CU<br />

One Connector Kit<br />

required for each<br />

breaker when panel<br />

mounted.<br />

3 Pole 3VA6 series Breakers – 100% rated – without connectors<br />

Standard in COMPAS includes ETU350 LSI Trip<br />

(Ir and Ii are adjustable)<br />

ETU350 LSI<br />

included<br />

3VA61/62 not allowed 3VA9243-0JD12<br />

3VA63 not allowed 3VA9373-0JD13<br />

3VA64<br />

ETU350 LSI<br />

included<br />

ETU350 LSI<br />

included<br />

ETU350 LSI<br />

included<br />

kA ratings @ 50/60 Hz 3-pole 3-pole 3-pole 3-pole<br />

240 VAC kAIC rating ==> 100 100 200 200<br />

480Y / 277 VAC kAIC rating ==> 35 65 100 150<br />

480 VAC kAIC rating ==> 35 65 100 150<br />

600Y / 347 VAC kAIC rating ==> 18 22 35 50<br />

600 VAC kAIC rating ==> 18 22 35 50<br />

250 VDC kAIC rating ==> na na na na<br />

amps Adj. Ir code<br />

3VA61 UL Type Code / MB code ==> MDAE / W2 HDAE / W3 CDAE / W4 LDAE a / W5<br />

40 16-40 40 3VA61 3P breaker w/trip 3VA6140-5HN31-2AA0 3VA6140-6HN31-2AA0 3VA6140-7HN31-2AA0 3VA6140-8HN31-2AA0<br />

100 40-100 10 3VA61 3P breaker w/trip 3VA6110-5HN31-2AA0 3VA6110-6HN31-2AA0 3VA6110-7HN31-2AA0 3VA6110-8HN31-2AA0<br />

150 60-150 15 3VA61 3P breaker w/trip 3VA6115-5HN31-2AA0 3VA6115-6HN31-2AA0 3VA6115-7HN31-2AA0 3VA6115-8HN31-2AA0<br />

3VA62 UL Type Code / MB code ==> MFAE / WA HFAE / WB CFAE / WC LFAE a / WD<br />

100 40-100 10 3VA62 3P breaker w/trip 3VA6210-5HN31-2AA0 3VA6210-6HN31-2AA0 3VA6210-7HN31-2AA0 3VA6210-8HN31-2AA0<br />

250 100-250 25 3VA62 3P breaker w/trip 3VA6225-5HN31-2AA0 3VA6225-6HN31-2AA0 3VA6225-7HN31-2AA0 3VA6225-8HN31-2AA0<br />

3VA63 UL Type Code / MB code ==> MJAE / WE HJAE / WF CJAE / WG LJAE a / WH<br />

250 100-250 25 3VA63 3P breaker w/trip 3VA6325-5HN31-2AA0 3VA6325-6HN31-2AA0 3VA6325-7HN31-2AA0 3VA6325-8HN31-2AA0<br />

3VA64 UL Type Code / MB code ==> MLAE / WJ HLAE / WK CLAE / WL LLAE a / WM<br />

400 160-400 40 3VA64 3P breaker w/trip 3VA6440-5HN31-2AA0 3VA6440-6HN31-2AA0 3VA6440-7HN31-2AA0 3VA6440-8HN31-2AA0<br />

Electronic Trip Units available for 3VA61/62/63/64 series<br />

(COMPAS may require special Mods for some options)<br />

Part #<br />

Display and/or<br />

Differences Alternate Trips available I r I i I sd I g Ground Fault type Metering Included<br />

…HL31-0AA0 ETU320 LI I r I i — — na no<br />

…HM31-0AA0 ETU330 LIG I r I i — I g Adjustable Protection (b) no<br />

…JP31-0AA0 ETU550 LSI with Display only I r I i I sd — na yes - Display only<br />

…JT31-0AA0 ETU556 LSI(G) with Display only I r I i I sd I g Adjustable Alarm (a) yes - Display only<br />

…JQ31-0AA0 ETU560 LSI(G) with Display only I r I i I sd I g Adjustable Protection (b) yes - Display only<br />

…KL31-0AA0 ETU820 LI w/Display & Metering I r I i — — na yes - both<br />

…KM31-0AA0 ETU830 LIG w/Display & Metering I r I i — I g Adjustable Protection (b) yes - both<br />

…KP31-0AA0 ETU850 LSI w/Display & Metering I r I i I sd — na yes - both<br />

…KT31-0AA0 ETU856 LSI(G) w/Display & Metering I r I i I sd I g Adjustable Alarm (a) yes - both<br />

…KQ31-0AA0 ETU860 LSIG w/Display & Metering I r I i I sd I g Adjustable Protection (b) yes - both<br />

Trip Unit Feature<br />

description and notes<br />

I r<br />

Adjustable Overload<br />

Protection<br />

I i<br />

I sd<br />

I g<br />

Adjustable<br />

Instantaneous Short-<br />

Circuit Protection<br />

Adjustable Delayed<br />

Short-Circuit Protection<br />

Either (a) Adjustable<br />

Ground-Fault Alarm<br />

or (b) Adjustable<br />

Ground-Fault<br />

Protection (not both)<br />

The "L" series of UL type codes may not be available<br />

for use in all Panelboard types - check COMPAS for<br />

verification.<br />

11-58<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog