3VA Breaker Configuration Information in Panelboards<br />

P4 Power Panel General information<br />

Minimum enclosure size: 32" wide x 10" deep<br />

P4 Power Panel<br />

P4 interiors have unit space setup for Multiple Branch<br />

Breaker Types and many different Main Breaker options.<br />

Neutral<br />

Connections*<br />

– at Main end<br />

of panel<br />

– Various configurations.<br />

* Depends on<br />

breaker selection<br />

- Consult factory<br />

for details<br />

Main Lugs<br />

shown<br />

installed<br />

Main Space<br />

– Mains are mounted<br />

in unit space<br />

– All are horizontal mount<br />

Vented Front Cover<br />

P4 Power Panel<br />

P4 Main Space can include:<br />

Main Lugs: 400A, 600A, 800A,<br />

1000A or 1200A<br />

Main Breaker Types: (horizontal mount)<br />

n 100A max. BL/BQD or 125A max. xGB or ED<br />

n 400A max. JD and VL-JG series<br />

n 600A max. LD and VL-LG series<br />

n 800A max. LM and VL-MG series<br />

Future 3VA offering in development:<br />

n 400A max. 3VA53/63 (TMTU/ETU)<br />

n 600A max. 3VA54/64 (TMTU/ETU)<br />

n 800A max. 3VA55/65 (TMTU/ETU)<br />

(ETU = Electronic Trip Unit)<br />

(TMTU = Thermal Magnetic Trip Unit)<br />

11 PANELBOARDS<br />

SEM3 CT's<br />

installed<br />

Various<br />

Branch<br />

Breaker<br />

Strap Kits<br />

installed<br />

Bus Bars:<br />

CU or AL<br />

SEM3<br />

Controller<br />

and Meter<br />

module<br />

racks<br />

P4 Unit Space<br />

below Bus:<br />

There is no<br />

actual Subfeed<br />

space.- All<br />

Space is unit<br />

space, but at<br />

the bottom<br />

below the<br />

bus, there can<br />

be additional<br />

components<br />

such as the<br />

SEM3 devices<br />

shown.<br />

Unit Space<br />

below Bus<br />

P4 Branch Breakers — Small Frame:<br />

a) 100A max BL series<br />

(10, 22, 65 kaic @ 240V)<br />

b) 100A max BQD series<br />

(14 kaic @ 480/277V)<br />

c) Various AFCI/GFCI series<br />

d) 125A max ED series (480V delta capable)<br />

e) 125A max xGB seriesf) 125A max<br />

GB2 series (480V delta capable)<br />

Future 3VA offering in development:<br />

g) 125A max. 3VA41 TMTU<br />

(480V delta capable)<br />

P4 Branch Breakers — Large Frame<br />

(6 max.)<br />

1) 150A max VL-DG series<br />

2) 150A 3VA61 ETU Series (new 2019)<br />

3) 225A max QR series<br />

4) 250A max FD or VL-FG series<br />

5) 250A max 3VA52/62 TMTU/ETU (new 2019)<br />

6) 400A max JD and VL-JG series<br />

7) 600A max. LD and VL-LG series<br />

8) 800A max. MD and VL-MG series<br />

Future 3VA offering in development:<br />

9) 400A max. 3VA53/63 (TMTU/ETU)<br />

10) 600A max. 3VA54/64 (TMTU/ETU)<br />

11) 800A max. 3VA55/65 (TMTU/ETU)<br />

New 3VA offerings have many field<br />

installable accessories available including<br />

strap kits.<br />

(See Strap Kit Table page 11-77).<br />

Vented Front Cover<br />

P4 Standard Box Width is 32" W<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-55