3VA Breaker Configuration Information in Panelboards<br />

Revised on 02/29/20<br />

3VA breaker Accessories Information<br />

Selection<br />

Panelboard Specific 3VA Accessories Available in Panelboards<br />

3VA Series Accessories<br />

There are 4 positions on each side of<br />

the trip handle of the 3VA52 breaker.<br />

Accessories can be 1, 2 or 3 positions<br />

wide and fit in specific locations as<br />

shown on charts and on the inside<br />

cover of each breaker.<br />

Accessory types:<br />

3VA breaker auxiliary releases allow<br />

remote electrical tripping of the circuit<br />

breaker<br />

n STL – Shunt Trip Left<br />

n STF – Shunt Trip Flexible<br />

n UVR – Undervoltage Releases Trip<br />

3VA UL Molded Case Circuit Breakers<br />

n<br />

Accessories UNI – Universal and Spare Release Parts - Shunt<br />

Trip and an Undervoltage Release<br />

Internal are Combined accessories<br />

■ Overview<br />

Color coding of accessories<br />

STL<br />

UVR<br />

UNI<br />

All Auxiliary and Alarm Switches for<br />

3VA breakers belong to an integrated<br />

range of accessories<br />

n AUX_HQ / AUX_HP – Auxiliary<br />

Switches<br />

n LCS_HQ / LCS_HP – Leading<br />

Changeover Switches<br />

n TAS_HQ / TAS_HP – Trip Alarm<br />

Switches<br />

n EAS_HQ / EAS_HP – Electrical<br />

alarm switches<br />

3VA Auxiliary and Alarm Switches<br />

have standard (HQ) and high capacity<br />

(HP) types as well as “electronic”<br />

versions for example: AUX_HQ_el<br />

* Padlock accessory will be available<br />

in a future release.<br />

LCS<br />

EAS<br />

3VA52 Breaker Features<br />

3VA Internal Breaker<br />

Accessories configurations<br />

TMTU<br />

Thermal-Magnetic trip<br />

Accessory Slots<br />

Frame<br />

width<br />

Amp<br />

range<br />

3VA41 - 1-pole 1p 15-125 0<br />

3VA41 - 1-pole in 2p frame<br />

3<br />

3VA41 - 2-pole<br />

2p 15-125<br />

3<br />

3VA41 - 3-pole 3p 15-125 6<br />

3VA51 - 1-pole 1p 15-125 0<br />

3VA51 - 1 pole in 2p frame 2p 15-125 3<br />

3VA51 - 2 pole in 3p frame<br />

6<br />

3VA51 - 3-pole<br />

3p 15-125<br />

6<br />

3VA51 - 3-pole MCS 3p 100 6<br />

3VA52 - 2-pole in 3p frame<br />

8<br />

3VA52 - 3-pole<br />

3p 100-250<br />

8<br />

3VA52 - 3-pole MCS 3p 100-250 8<br />

3VA53 - 3-pole 3p 200-400 10<br />

ETU - Electronic Trip*<br />

3VA61 - 3 pole 3p 16-150 8<br />

3VA62 - 3-pole 3p 40-250 8<br />

3VA63 - 3-pole 3p 100-400 10<br />

3VA64 - 3-pole 3p 160-600 10<br />

11 PANELBOARDS<br />

* 100% rated may have reduced ranges<br />

3VA6 ETU only<br />

STF<br />

COM060<br />

24 V module Lock adapter for<br />

mounting the<br />

cylinder lock<br />

AUX<br />

TAS<br />

I201_19551<br />

A color coding system has been used to clearly identify the<br />

specific functions of individual accessories:<br />

Color Auxiliary switches and alarm switches Auxiliary releases<br />

Black Auxiliary switch AUX • Shunt trip left STL<br />

• Shunt trip flexible STF<br />

Gray Leading changeover switch LCS • Undervoltage release UVR<br />

Yellow Trip alarm switch TAS --<br />

Green Electrical alarm switch EAS --<br />

Blue -- Universal release UNI<br />

Auxiliary switches<br />

All auxiliary and alarm switches for the 3VA UL molded case<br />

circuit breakers belong to an integrated range of accessories.<br />

The auxiliary switches can be simply snapped into place and<br />

connected up in the accessories compartment provided on the<br />

front face of the unit to the left and right of the handle.<br />

The purpose of the auxiliary switches (AUX) is to signal the<br />

position of the main contacts of the molded case circuit breaker.<br />

The contacts of the auxiliary switches open and close<br />

simultaneously with the main contacts of the molded case circuit<br />

breaker.<br />

Leading changeover switches (LCS) signal the opening of the<br />

Auxiliary releases<br />

Auxiliary releases allow remote electrical tripping of the circuit<br />

breaker. They can be used to monitor control or main circuits in<br />

order to implement 3VA a accessories protective system install against easily. accidental<br />

restart following a power failure, for example.<br />

Special Hardware kit for P3 Twin Mount aligns screw<br />

Undervoltage<br />

for<br />

releases<br />

easy<br />

trip<br />

installation.<br />

the 3VA UL molded case circuit<br />

breaker in the event that the rated voltage of a monitored circuit<br />

drops below a minimum permissible limit or fails altogether.<br />

Shunt trips can be used Siemens to trip Industry, the 3VA Inc. UL SPEEDFAX molded case Product circuit Catalog 11-51<br />

breaker remotely. The STF variant can be mounted in either the<br />

left-hand or the right-hand accessories compartment (for 3VA6<br />

only). The STL type is specifically designed for mounting in the