12.01.2021 Views

Speedfax 2017

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Panelboards<br />

Type P3 Panelboards<br />

Revised on 04/30/19<br />

Selection<br />

P3 Branch Circuit Breakers<br />

Amp<br />

Rating<br />

100<br />

xx<br />

125<br />

225<br />

250<br />

Trip<br />

Type<br />

Thermal<br />

Magnetic<br />

Breaker<br />

Family<br />

BL<br />

Special BLG<br />

Application BL<br />

Thermal<br />

Magnetic<br />

BQD<br />

Electronic<br />

and misc.<br />

Thermal<br />

Magnetic<br />

Thermal<br />

Magnetic<br />

Thermal<br />

Magnetic<br />

BL<br />

GB<br />

Sentron<br />

GB2<br />

3VA41 c<br />

QR<br />

3VA52 d<br />

(W/TM230<br />

trip)<br />

Breaker<br />

Type<br />

1-Pole<br />

Max IR (kA) at<br />

120V 277V 347V<br />

125V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

2-Pole and 3-Pole<br />

Max IR (kA) at<br />

120/<br />

240V<br />

240V<br />

480Y/<br />

277V<br />

480V<br />

600Y/<br />

347V<br />

600V<br />

125/<br />

250V<br />

DC<br />

250V<br />

DC<br />

Amp<br />

Ratings<br />

Avail.<br />

S = Single Mount<br />

T = Twin mount<br />

S<br />

T<br />

Unit Max<br />

Space 1-pole<br />

per Kit Circuits<br />

(in.) per Kit<br />

BL 10 — — — 15-70 10 10 — — — — — — 15-100 d — T 3.00 6<br />

BLH 22 — — — 15-70 22 22 — — — — — — 15-100 d — T 3.00 6<br />

HBL 65 — — — 15-50 65 65 — — — — — — 15-100 — T 3.00 6<br />

BLG a 10 — — — 15-20 10 — — — — — — — 30 — T 3.00 6<br />

BL (HID) 10 — — — 15-30 10 — — — — — — — 15-30 — T 3.00 6<br />

BQD f 65 14 — 14 15-100 — 65 14 — — — 14 — 15-100 — T 3.00 6<br />

BQD6 g 65 — — 14 15-70 — 65 — 10 — 14 — 15-70 — T 3.00 6<br />

AFCI/<br />

GFCI<br />

& Dual<br />

Function<br />

x — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

x — — — — — — —<br />

see<br />

special<br />

table<br />

page<br />

11-13<br />

— T 3.00 6<br />

NGB 100 25 14 14 15-125 — 100 25 — 14 — 14 — 15-125 — T 3.00 6<br />

HGB 100 35 14 14 15-125 — 100 35 — 14 — 14 — 15-125 — T 3.00 6<br />

LGB 100 65 14 14 15-125 — 100 65 — 14 — 14 — 15-125 — T 3.00 6<br />

ED4 — 22 — 30 15-100 — 65 — 18 — — — 30 15-125 — T 3.00 6<br />

ED6 — — — — — — 65 — 25 — 18 — 30 20-125 — T 3.00 6<br />

HED4 b — — — — — — 65 — 18 b — — — 30 15-125 — T 3.00 6<br />

HHED6 — — — — — — 100 — 65 — 18 — — 15-50 — T 3.00 6<br />

NGB2 100 25 14 14 d 15-125 — 100 — 25 14 — 14 e — 15-125 — T 3.00 6<br />

HGB2 100 35 22 14 d 15-125 — 100 — 35 22 — 14 e — 15-125 — T 3.00 6<br />

LGB2 100 65 25 14 d 15-125 — 100 — 65 25 — 14 e — 15-125 — T 3.00 6<br />

info not x x x x x x x — x — — x — T 3.00 6<br />

yet available<br />

x x x x x x x — x — — x — T 3.00 6<br />

x x x x x x x — x — — x — T 3.00 6<br />

QR2 — — — — — — 10 — — — — — — 100-225 — T 6.00 6<br />

QRH2 — — — — — — 25 — — — — — — 100-225 — T 6.00 6<br />

HQR2 — — — — — — 65 — — — — — — 100-225 — T 6.00 6<br />

HQR2H — — — — — — 100 — — — — — — 100-225 — T 6.00 6<br />

MFAS — — — — — 85 85 — 35 — 18 — — 100-250 — T 6.00 6<br />

HFAS — — — — — 100 100 — 65 — 25 — — 100-250 — T 6.00 6<br />

CFAS — — — — — 200 200 — 100 — 35 — — 100-250 — T 6.00 6<br />

11 PANELBOARDS<br />

Subfeed Breakers (available in 2-pole or 3-pole)<br />

Breaker<br />

Type<br />

Mounting Position When<br />

Used as Subfeed Breaker<br />

Ampere<br />

Ratings<br />

For Load<br />

Maximum Interrupting Rating<br />

(kA) Symmetrical<br />

240V AC 480V AC 600V AC<br />

FD6 h , FXD6 Twin (Vertical) 70–250 65 35 18<br />

HFD6 h , HFXD6 Twin (Vertical) 70–250 100 65 25<br />

JD6 i , JXD6 Single (Horizontal) 200–400 65 35 25<br />

HJD6 i , HJXD6 Single (Horizontal) 200–400 100 65 35<br />

Neutral Connectors<br />

Wire Range<br />

Max.<br />

Number of Max.<br />

Connections Amps<br />

#14-#1/0 44 125<br />

#4 - 350 kcmil 6 250<br />

(1)#4 - 600 kcmil or<br />

(2)#6 - 250 kcmil<br />

1 400<br />

a BLG two-pole breaker is one phase and neutral. Three<br />

pole is two phases and neutral - See SpeedFax page 7-31<br />

b 1-pole HED 15-30A rated 65kA; 35-100A rated 25kA:<br />

3-pole HED rated 42kA<br />

c Availability and additional specs tbd, expected late 2019.<br />

(COMPAS may allow selection of alternate trip units)<br />

d Twin Mount 3VA52 available 2018 with Thermal<br />

Magnetic Trip (TMTU), 3VA62 with Electronic Trip<br />

(ETU) availability tbd.<br />

e 2-pole only or two outer poles of 3-pole breaker<br />

f Approved for CSA and UL Listed.<br />

g Approved for CSA but not UL Listed.<br />

h Twin mounted subfeed breakers are mounted at bottom<br />

of panelboard only and adds 24" to the panel height.<br />

i Subfeed breaker is mounted at bottom of panelboard<br />

only. 400 amp subfeed breaker adds 30" to the panel<br />

height.<br />

Product Category PBSB<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!