12.01.2021 Views

Speedfax 2017

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Panelboards<br />

Type P3 Panelboards<br />

Revised on 04/30/19<br />

Selection/Dimensions<br />

Panel Unit Space To Box Height Requirements<br />

P3 Panels With Standard Line Lugs. Unit Space (starting with 9" and adding 6" increments) “A” Dimension<br />

Main Lugs<br />

Main Breakers<br />

“B” 250A 250A 250A 400A 400A 600A 600A<br />

Dimension Horiz. Vert. Vert. Vert. Vert. Vert. Vert.<br />

Box Height 250A 400A 600A 800A FD FD CFD JD CJD LD CLD<br />

56 27 21 21 21 21 15 9 9 — 9 —<br />

62 33 27 27 27 27 21 15 15 9 15 9<br />

68 39 33 33 33 33 27 21 21 15 21 15<br />

74 45 39 39 39 39 33 27 27 21 27 21<br />

80 45 45 45 45 45 39 33 33 27 33 27<br />

11 PANELBOARDS<br />

Main Breaker Wire Bending<br />

Breaker<br />

Frame C E F<br />

FD Horiz. 7.25 — 20.13<br />

FD Vert. — 12.25 25.38<br />

CFD — 13.63 31.38<br />

JD — 15.63 29.38<br />

CJD — 14.75 35.38<br />

LD — 14.75 29.38<br />

CLD — 14.00 35.38<br />

Main Lug Wire Bending<br />

Panel Amps Standard Connectors C D<br />

250 (1) #6 AWG - 350 kcmil 10.75 1 13.50<br />

400 (2) #3/0 AWG - 250 kcmil 16.00 17.88<br />

or (1) 600 kcmil<br />

600 (2) #3/0 AWG - 500 kcmil 16.00 17.88<br />

800 b (2) 600 kcmil 16.00 17.88<br />

aThis lug is removable.<br />

bCU wire Required for 800A with 2 cables. See Alternate<br />

Lugs page 11-47 for 3 cables CU or AL options.<br />

Main Breaker Wire Bending Diagram<br />

Main Lug Wire Bending Diagram<br />

Box depth = 7.75 in. (197 mm)<br />

Box width = 24 in. (610 mm)<br />

Main Breaker Wire Bending<br />

Branch Breaker<br />

Side Gutters Inches (mm)<br />

Reference<br />

Panel<br />

Letter Width 24" (609)<br />

A 7.750 (197)<br />

B 7.125 (181)<br />

C 6.000 (152)<br />

D 1 7.000 (178)<br />

E 5.000 (127)<br />

F 6.625 (168)<br />

G 5.500 (140)<br />

a Single branch mounting construction.<br />

b BQD6 is not UL Listed. Only for CUL and CSA panels.<br />

Box depth = 7.75 in. (197 mm)<br />

Box width = 24 in. (610 mm)<br />

Main Lug Wire Bending<br />

Branch Breaker Wire Bending Diagram<br />

A<br />

BL, BLH, HBL<br />

BL, BLH, HBL<br />

BLF2, BLHF2<br />

BLF2, BLHF2<br />

A<br />

B HBLF2, BLFB, BLHFB HBLF2, BLFB, BLHFB B<br />

BQD, BQD6 b<br />

BQD, BQD6 b<br />

C<br />

D/E<br />

F<br />

ED4, ED6<br />

QR2, QRH2<br />

NGB, HGB, LGB<br />

ED4, ED6<br />

QR2, QRH2<br />

NGB, HGB, LGB<br />

HED4, HHED6<br />

HQR2, HQR2H<br />

NGB2, HGB2, LGB2<br />

HED4, HHED6<br />

HQR2, HQR2H<br />

NGB2, HGB2, LGB2<br />

C<br />

D/E<br />

F<br />

G<br />

MFAS, HFAS, CFAS MFAS, HFAS, CFAS<br />

(3VA52)<br />

(3VA52)<br />

G<br />

Panel Width<br />

24 in. (610 mm)<br />

Branch Breaker Side Gutters<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 11-41