Distribution Dry Type Transformers<br />

Three Phase<br />

Revised on 05/15/18<br />

Selection<br />

kVA<br />

Catalog<br />

Temperature<br />

Number Taps a Rise<br />

Insulation<br />

Mounting<br />

Type bi<br />

Drip Shield<br />

Provided c<br />

Enclosure<br />

Style d<br />

Optional<br />

Modifications<br />

600 Volts ∆ Primary, 208Y/120 Volts Secondary<br />

3 3G3R003 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

6 3G3R006 R 135° C 180° C Wall No 1, 2, 3<br />

9 3G3R009 R 135° C 180° C Wall No 1, 2, 3<br />

15 3G3R015 R 135° C 180° C Wall No 1, 2, 3<br />

15 3G3T015D16 Y , T 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3G3T030D16 Y , T 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3G3T045D16 Y , T 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3G3T075D16 Y , T 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3G3T112D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3G3T150D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3G3T225D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

300 3G3T300D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3G3T500D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

600 Volts ∆ Primary, 480Y/277 Volts Secondary<br />

3 3G5R003 R 135° C 180° C Wall No Encapsulated – NEMA 3R 1, 2, 3<br />

6 3G5R006 R 135° C 180° C Wall No 1, 2, 3<br />

9 3G5R009 R 135° C 180° C Wall No 1, 2, 3<br />

15 3G5R015 R 135° C 180° C Wall No 1, 2, 3<br />

15 3G5T015D16 Y , T 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 1, 2, 3, 4, 6<br />

30 3G5T030D16 Y , T 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

45 3G5T045D16 Y , T 150° C 220° C Floor & Wall Yes 1, 2, 3, 4, 6<br />

75 3G5T075D16 Y , T 150° C 220° C Floor Yes Ventilated – NEMA 3R 1, 2, 3, 6<br />

112.5 3G5T112D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

150 3G5T150D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

225 3G5T225D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

300 3G5T300D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

500 3G5T500D16 Y , T 150° C 220° C Floor Yes 1, 2, 3, 6<br />

Dual Purpose Auto Transformers <br />

8<br />

600V Pri<br />

480V Sec<br />

kVA<br />

480V Pri<br />

380V Sec<br />

Catalog<br />

Temperature<br />

Number Taps a Rise<br />

Insulation<br />

Mounting<br />

Type b<br />

Drip Shield<br />

Required c<br />

Enclosure<br />

Style d<br />

Optional<br />

Modifications<br />

600 Volts Primary, 480 Volts Secondary 3Ø 60 Hz OR— 480 Volts Primary 380 Volts Secondary 3Ø 50/60 Hz Alternate Rating<br />

15 12 3G4N015A N 80° C 130° C Wall No Encapsulated – NEMA 3R —<br />

30 24 3G4N030A N 115° C 180° C Wall No —<br />

45 36 3G4N045A N 150° C 220° C Floor & Wall Yes Ventilated – NEMA 3R 4, 5<br />

75 60 3G4N075A N 150° C 220° C Floor & Wall Yes 4, 5<br />

112.5 90 3G4N112A N 150° C 220° C Floor & Wall Yes 4, 5<br />

150 120 3G4N150A N 150° C 220° C Floor & Wall Yes 4, 5<br />

225 180 3G4N225A N 150° C 220° C Floor & Wall Yes 4, 5<br />

300 240 3G4N300A N 150° C 220° C Floor Yes 5<br />

500 400 3G4N500A N 150° C 220° C Floor Yes 51<br />

TRANSFORMERS<br />

Optional Modifications Table (Contact Sales office for List Price)<br />

Optional (commonly used) Catalog<br />

Modifications<br />

Suffix Code<br />

1a. 115° C Rise F<br />

1b. 80° C Rise B<br />

2. Electrostatic Shield ES<br />

3. Copper Windings C<br />

4. Wall Mounting Brackets1 W<br />

6. Low noise - XdB below std. LNX<br />

Taps<br />

Description<br />

Designation<br />

None<br />

N<br />

2–5% FCBN R<br />

2–5% (1 FCAN, 1 FCBN) S<br />

2–2.5% FCBN U<br />

6–2.5% (2 FCAN, 4 FCBN) Y<br />

a Actual taps may vary based on volts/turn ratio.<br />

b Wall designations for units having standard features.<br />

c Ventilated transformers drip shields are UL listed for<br />

outdoor use.<br />

d Encapsulated transformers are UL listed for indoor/<br />

outdoor use.<br />

If used on unbalanced loads, these auto transformers will<br />

need to be used on a 4-wire system with the supply<br />

neutral connected to the transformer. If used on motor<br />

loads, then they may be used on a 3-wire system without<br />

a neutral or fourth wire. Review in NEC 450-4 and 450-5.<br />

Items marked floor and wall can be wall mounted<br />

with optional wall bracket that may be identified<br />

with “W” suffix on catalog number. Wall mounting<br />

brackets will not be available for Series J 75kVA with<br />

copper winding options. See pages 8-8 and 8-27 for<br />

details.<br />

Series H Tap Standard.<br />

Series J Tap Standard.<br />

i See table on page 8-8 for available kits.<br />

8-14<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category XFMR