Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 05/31/18<br />

Selection<br />

Thermal-Magnetic Trip Breakers<br />

& Electronic Trip Breakers<br />

General Purpose<br />

Breakers<br />

Solid State Trip Circuit Breakers<br />

RD6, a HRD6, a<br />

RXD6 a HRXD6 a SJD6 SHJD6 SCJD6 SLD6 SHLD6 SCLD6<br />

Page 7-139 7-139 7-119 7-119 7-119 7-123 7-123 7-123<br />

Poles 3 3 3 3 3 3 3 3<br />

Amperes, Continuous 1600-2000 1600-2000 200-400 200-400 200-400 300-600 300-600 300-600<br />

Volts 50/60 HZ 3-Pole 600 600 600 600 600 600 600 600<br />

240V 65,000 100,000 65,000 100,000 200,000 65,000 100,000 200,000<br />

UL 480V 50,000 65,000 35,000 65,000 150,000 35,000 65,000 150,000<br />

600V 25,000 50,000 25,000 35,000 100,000 25,000 35,000 100,000<br />

AC<br />

Ratings<br />

Interrupt Rating<br />

Symmetrical RMS<br />

220/240V Icu — — — — — — — —<br />

Ics — — — — — — — —<br />

Amperes<br />

IEC60947-2 Icu — — — — — — — —<br />

380/415V<br />

50/60HZ Ics — — — — — — — —<br />

500V<br />

Icu — — — — — — — —<br />

Ics — — — — — — — —<br />

2-Pole 250V DC Interrupting Ratings 30,000 30,000 — — — — — —<br />

DC<br />

3-Pole, 500V DC Interrupting Ratings a 25,000 50,000 — — — — — —<br />

Height 16.00 16.00 11.00 11.00 17.86 11.0 11.00 17.86<br />

Dimensions in<br />

Width 3-Pole 9.00 9.00 7.50 7.50 7.50 7.50 7.50 7.50<br />

inches<br />

Depth 6.19 6.19 4.00 4.00 4.00 4.00 4.00 4.00<br />

Solid State Trip — — u u u u u u<br />

Optional DAS / Maintenance Mode — — u u u u u u<br />

Overcurrent Thermal and Adjustable Magnetic Trip u u — — — — — —<br />

Devices Adjustable Magnetic Trip Only — — — — — — — —<br />

Motor Circuit Protector<br />

Molded Case Switch u — — — — — — —<br />

Undervoltage Trip u u u u u u u u<br />

Shunt Trip u u u u u u u u<br />

Auxiliary Switch u u u u u u u u<br />

Accessories & Alarm Switch u u u u u u u u<br />

Modifications Mechanical Interlock u u u u u u u u<br />

Rear Connections Studs — — u u u u u u<br />

Electric Motor Operator u u u u u u u u<br />

Plug-In Mounting Assembly — — u u u u u u<br />

Fungus Proofing (ref. page 7-156) u u u u u u u u<br />

Mounting Block (required) u u — — — — — —<br />

Type 1 — Indoor Surface u u u u u u u u<br />

Type 1 — Indoor, Flush — — — — — — — —<br />

Type 3R — Outdoor-Rainproof — — u u — u u —<br />

Individual<br />

Enclosures<br />

Type 7 — Flammable Gas Atmosphere — — u u — u u —<br />

Type 9 — Combustion Dusttight — — u u — u u —<br />

Type 5, 12 — Lint, Fine Dust, Oils, Coolants — — u u u u u u<br />

Type 12K — Semi-Dusttight — — u u u u u u<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion, see Application Data section.<br />

a Requires Connect-all mounting assembly. Dimensions<br />

shown are for circuit breaker only.<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 7-15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!