Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 10/31/18<br />

Selection/Application<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

Thermal-Magnetic Trip Breakers<br />

General Purpose Breakers<br />

LMD6,<br />

LMXD6<br />

HLMD6,<br />

HLMXD6<br />

MD6,<br />

MXD6<br />

HMD6,<br />

HMXD6 CMD6<br />

ND6,<br />

NXD6<br />

HND6,<br />

HNXD6 CND6<br />

PD6, b<br />

PXD6 b<br />

HPD6, b<br />

HPXD6 b CPD6 b<br />

Page 7-125 7-126 7-128 7-129 7-129 7-132 7-133 7-133 7-136 7-136 7-136<br />

Poles 2, 3 2, 3 2, 3 2, 3 3 2, 3 2, 3 3 3 3 3<br />

Ratings<br />

AC<br />

DC<br />

Dimensions<br />

in inches<br />

Amperes, Continuous<br />

Volts 50/60 HZ<br />

Interrupt Rating<br />

Symmetrical RMS Amperes<br />

500-<br />

800<br />

500-<br />

800<br />

500-<br />

800<br />

500-<br />

800<br />

400-<br />

800<br />

2-Pole<br />

3-Pole<br />

600 600 600 600 600 600 600 600 600 600 600<br />

240V 65,000 100,000 65,000 100,000 200,000 65,000 100,000 200,000 65,000 100,000 200,000<br />

UL<br />

480V 50,000 65,000 50,000 65,000 100,0001 50,000 65,000 100,000 50,000 65,000 100,000<br />

600V 25,000 50,000 25,000 50,000 65,0001 25,000 50,000 65,000 25,000 50,000 65,000<br />

415V Ics — — 20,000 33,000 — 20,00011 33,000 — — — —<br />

220/ Icu — — 65,000 100,000 — 65,000 100,000 — — — —<br />

240V Ics — — 33,000 50,000 — 33,0001 50,000 — — — —<br />

IEC 947-2<br />

50/60HZ c 380/ Icu — — 40,000 65,000 — 40,0001 65,000 — — — —<br />

500V<br />

Icu — — — — —1 — — — — — —<br />

Ics — — — — — —1 — — — — —<br />

2-Pole 250V DC Interrupting Ratings 30,000 30,000 30,000 30,000 30,0001 30,0001 30,000 30,000 30,000 30,000 30,000<br />

3-Pole, 500V DC Interrupting Ratings a 25,000 50,000 25,000 50,000 50,000 25,00011 50,000 50,000 25,000 50,000 50,000<br />

Circuit breakers require<br />

Connect-all mounting<br />

block. Dims shown are<br />

for circuit breaker only.<br />

Height 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.0 16.00 16.00<br />

Width 7.50 7.50 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00<br />

Depth 4.59 4.59 6.19 6.19 6.19 6.191 6.19 6.19 6.19 6.19 6.19<br />

Overcurrent Thermal and Adjustable Magnetic Trip u u u u u u u u u u u<br />

Devices Adjustable Magnetic Trip Only<br />

Motor Circuit Protector<br />

u — u — u — — — — —<br />

—<br />

Molded Case Switch u — u u — —<br />

Accessories Undervoltage Trip u — u — u u u u u u u<br />

and Shunt Trip u u u u u u u u u u u<br />

Modifications<br />

Auxiliary Switch u u u u u u u u u u u<br />

Alarm Switch u u u u u u u u u u u<br />

Mechanical Interlock u u u u u u u u u u u<br />

Rear Connections Studs u u u u u u u u — — —<br />

Electric Motor Operator u u u u u u u u u u u<br />

Plug-in Mounting Assembly u u u u u u u u — — —<br />

Fungus Proofing (ref. page 7-156) — — u u u u u u u u u<br />

Mounting Block (required) — — — — — — — — u u u<br />

Individual<br />

Enclosures<br />

Type 1 — Indoor Surface u u u u u u u u u u u<br />

Type 1 — Indoor, Flush — — — — — — — — — — —<br />

Type 3R — Outdoor-Rainproof u u u u u u u u — — —<br />

Type 7 — Flammable Gas Atmosphere — — — — — — — — — — —<br />

Type 9 — Combustion Dusttight — — — — — — — — — — —<br />

Type 5, 12 — Lint, Fine Dust, Oils,<br />

Coolants<br />

— — — — — — — — — — —<br />

Type 12K — Semi-Dusttight u u u u u u u u — — —<br />

800-<br />

1200<br />

800-<br />

1200<br />

800-<br />

1200<br />

1200-<br />

1600<br />

1200-<br />

1600<br />

1200-<br />

1600<br />

For inches / millimeters conversion, see Application Data section.<br />

a For DC UPS application.<br />

b Requires Connect-all mounting assembly. Dimensions<br />

shown are for circuit breaker only.<br />

c Only applicable to non-interchangeable trip unit types:<br />

NXD6, HNXD6, MXD6 and HMXD6<br />

7-14<br />