Molded Case Circuit Breakers<br />

Reference Guide<br />

Revised on 10/31/18<br />

Selection/Application<br />

Thermal-Magnetic Trip Breakers<br />

General Purpose Breakers<br />

JXD2-A<br />

JD6-A,<br />

JXD6-A<br />

HJD6-A,<br />

HJXD6-A<br />

HHJD6-A,<br />

HHJXD6-A CJD6-A<br />

LD6,<br />

LXD6<br />

HLD6,<br />

HLXD6<br />

HHLD6,<br />

HHLXD6 CLD6-A<br />

Page 7-117 7-117 7-118 7-118 7-118 7-121 7-122 7-122 7-122<br />

Poles 2, 3 2, 3 2, 3 2, 3 3 2, 3 2, 3 2, 3 3<br />

Amperes, Continuous 200-400 200-400 200-400 200-400 200-400 250-600 250-600 250-600 450-600<br />

Volts 50/60HZ<br />

2-Pole<br />

3-Pole<br />

240 600 600 600 600 600 600 600 600<br />

Ratings<br />

AC<br />

DC<br />

Dimensions in<br />

inches<br />

Overcurrent<br />

Devices<br />

Accessories &<br />

Modifications<br />

Individual<br />

Enclosures<br />

Interrupt Rating<br />

Symmetrical RMS Amperes<br />

UL<br />

220/<br />

240V<br />

IEC 947-2 380/<br />

50/60HZ a 415V<br />

240V 65,000 65,000 100,000 200,000 200,000 65,000 100,000 200,000 200,000<br />

480V — 35,000 65,000 100,000 150,000 35,000 65,000 100,000 150,000<br />

600V — 25,000 35,000 50,000 100,000 25,000 35,000 50, 000 100,000<br />

Icu — 65,000 100,000 — — 65,000 100,000 — —<br />

Ics — 33,000 50,000 — — 33,000 50,000 — —<br />

Icu — 40,000 65,000 — — 40,000 65,000 — —<br />

Ics — 20,000 33,000 — — 20,000 33,000 — —<br />

500V Icu — — — — — — — — —<br />

Ics — — — — — — — — —<br />

2-Pole 250V DC Interrupting Ratings 30,000 30,000 30,000 — — 30,000 30,000 — —<br />

3-Pole, 500V DC Interrupting Ratings b — 25,000 35,000 — 50,000 35,000 — — 50, 000<br />

Height 11.00 11.00 11.00 11.00 17.86 11.00 11.00 11.00 17.86<br />

Width 2, 3-Pole 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50 7.50<br />

Depth 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00<br />

Thermal and Fixed Magnetic Trip — — — — — — — — —<br />

Thermal and Adjustable Magnetic Trip u u u u u u u u u<br />

Adjustable Magnetic Trip Only<br />

Motor Circuit Protector<br />

— u — — u u — — u<br />

Molded Case Switch u u u — u u u — u<br />

Undervoltage Trip u u u u u u u u u<br />

Shunt Trip u u u u u u u u u<br />

Auxiliary Switch u u u u u u u u u<br />

Alarm Switch u u u u u u u u u<br />

Mechanical Interlock u u u u u u u u u<br />

Rear Connection Studs u u u u u u u u u<br />

Electric Motor Operator u u u u u u u u u<br />

Plug-In Mounting Assembly u u u u u u u u u<br />

Fungus Proofing (ref. page 7-156) — u u u u u u u u<br />

Type 1 — Indoor Surface u u u u u u u u u<br />

Type 1 — Indoor, Flush — — — — — — — — —<br />

Type 3R — Outdoor-Rainproof u u u u u u u u u<br />

Type 7 — Flammable Gas Atmosphere u u u u — u u u —<br />

Type 9 — Combustion Dusttight u u u u — u u u —<br />

Type 5, 12 — Lint, Fine Dust, Oils, Coolants u u u u u u u u u<br />

Type 12K — Semi-Dusttight u u u u u u u u u<br />

7<br />

MOLDED CASE<br />

CIRCUIT BREAKERS<br />

For inches / millimeters conversion, see Application Data section.<br />

a Only applicable to non-interchangeable trip unit types:<br />

JXD6-A, HJXD6-A, LXD6 and HLXD6<br />

b For DC UPS application.<br />