Speedfax 2017
Power Mod Revised on 06/30/19 Type WMN ConEd Residential Meter Stacks 3 WMN ConEd Residential Meter Stacks Siemens Consolidated Edison Residential Meter Stacks are packed with features inside and out; our exclusive knock out plate offers flexibility when pulling wires to the stack, moveable neutrals and grounds to save wire, and all of the QuickSystem features all designed with the contractor in mind. Features 10" socket center-to-center distance to allow use of meter pulling tools. METER CENTERS Surge Protection Module quick reference n 2-6 gang n 125/225 Amp per position n 1200Amp horizontal bus rating n UL standard 67 n UL file no. E27100 n AIC rating: (100K) n Voltage – 3 phase in single phase out – 240V AC max n All swing latches and rivets are stainless steel n Outdoor = NEMA 3R rated n Indoor = NEMA 1R rated n G90 galvanized steel n ANSI 61 paint 3-94 Siemens Industry, Inc. SPEEDFAX Product Catalog
Power Mod Revised on 06/30/19 Type WMN ConEd Residential Meter Stacks Main Features: n 2-6 gang n 1200 amp horizontal bus rating n Suitable for 100k AIC applications 3 METER CENTERS Residential 5-jaw ring type meter stacks; 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing c Outdoor Catalog number Indoor Catalog number Max. tenant breaker (Amps): 125 Meter positions per stack WMN22125J MN22125J 2 Breaker provision a Maximum Dimensions (inches) Knockout AIC Height Width Depth Diagram 100k 35.31 12.97 8.09 WMN-1 WMN32125J MN32125J 3 QP, QPH, 100k 46.31 12.97 8.09 WMN-2 WMN42125J MN42125J 4 HQP, HQPH, MP-T, MP-HT, 100k 56.31 12.97 8.09 WMN-3 WMN52125J MN52125J 5 MPMT 100k 66.31 12.97 8.09 WMN-4 WMN62125J MN62125J 6 100k 76.31 12.97 8.09 WMN-5 Max. tenant breaker (Amps): 225 b WMN22225J MN22225J 2 100k 35.31 16.09 8.09 WMN-6 WMN32225J WMN42225J WMN52225J MN32225J MN42225J MN52225J 3 4 5 QS, QSH, QSHH, HQS, HQSH, QP, QPH, HQP, HQPH, MP-T, MP-HT, MPMT 100k 100k 100k 46.31 56.31 66.31 16.09 16.09 16.09 8.09 8.09 8.09 WMN-7 WMN-8 WMN-9 WMN62225J MN62225J 6 100k 76.31 16.09 8.09 WMN-10 Dimensions shown are representative of outside box dimensions and do not include allowances for mounting bumps, endwalls, covers, hubs, or hardware protrusions. Dimensions are subject to change. 225A available in lower three positions only. 200A continuous for all other positions. Must use QuickPhase features to route all sockets AWAY from high-leg when 240/120 Delta voltage is used. Max AIC determined by maximum AIC of tenant breakers. Install QP breakers below QS. Siemens Industry, Inc. SPEEDFAX Product Catalog 3-95
- Page 179 and 180: Power Mod Revised on 10/31/19 Type
- Page 181 and 182: Power Mod Revised on 12/13/17 Type
- Page 183 and 184: Power Mod Revised on 10/31/19 Type
- Page 185 and 186: Power Mod Revised on 10/31/19 Type
- Page 187 and 188: Power Mod Type WT Feed Thru Tap box
- Page 189 and 190: Power Mod Revised on 06/30/19 Type
- Page 191 and 192: Power Mod Revised on 06/30/19 Type
- Page 193 and 194: Power Mod Power Mod Residential Met
- Page 195 and 196: Power Mod Revised on 06/30/19 Type
- Page 197 and 198: Power Mod Revised on 06/30/19 Type
- Page 199 and 200: Power Mod Revised on 06/30/19 Type
- Page 201 and 202: Power Mod Meter Stacks: WML Lever B
- Page 203 and 204: Power Mod Meter Stacks: WML Lever B
- Page 205 and 206: Power Mod Revised on 10/31/19 Type
- Page 207 and 208: Power Mod Type WMLZF and WMLZ Utili
- Page 209 and 210: Power Mod Revised on 06/30/19 Type
- Page 211 and 212: Power Mod Type WMT Test Block Bypas
- Page 213 and 214: Power Mod Revised on 06/30/19 Type
- Page 215 and 216: Power Mod Revised on 10/31/19 Type
- Page 217 and 218: Power Mod Revised on 10/31/19 Type
- Page 219 and 220: Power Mod Revised on 10/31/19 Type
- Page 221 and 222: Power Mod Type WCL Lever Bypass Hou
- Page 223 and 224: Power Mod Revised on 10/31/19 Type
- Page 225 and 226: Power Mod Revised on 11/30/20 Type
- Page 227 and 228: Power Mod Type WSPD Surge Protectio
- Page 229: Power Mod Revised on 11/30/20 Type
- Page 233 and 234: Power Mod Type WMN ConEd Residentia
- Page 235 and 236: Power Mod Revised on 06/30/19 Type
- Page 237 and 238: Power Mod Revised on 06/30/19 WMMB
- Page 239 and 240: Power Mod Revised on 04/30/20 Expan
- Page 241 and 242: Uni-PAK Revised on 03/31/18 Uni-PAK
- Page 243 and 244: Uni-PAK Revised on 06/30/19 Uni-PAK
- Page 245 and 246: Uni-PAK Revised on 06/30/19 Uni-PAK
- Page 247 and 248: Uni-PAK Revised on 06/30/19 Uni-PAK
- Page 249 and 250: Uni-PAK Uni-PAK Metering: Dimension
- Page 251 and 252: Uni-PAK Uni-PAK Metering: Dimension
- Page 253 and 254: Uni-PAK Uni-PAK Metering: Dimension
- Page 255 and 256: Uni-PAK Uni-PAK Metering: Dimension
- Page 257 and 258: Uni-PAK Uni-PAK Metering: Dimension
- Page 259 and 260: Uni-PAK Uni-PAK Metering: Dimension
- Page 261 and 262: Uni-PAK Uni-PAK Metering: Dimension
- Page 263 and 264: Uni-PAK Uni-PAK Metering: Dimension
- Page 265 and 266: Power Mod Revised on 10/31/19 Lug K
- Page 267 and 268: Power Mod Revised on 10/31/19 Modul
- Page 269 and 270: Power Mod and Uni-PAK Revised on 10
- Page 271 and 272: Power Mod and Uni-PAK Revised on 10
- Page 273 and 274: Power Mod and Uni-PAK Revised on 06
- Page 275 and 276: Uni-PAK Metering Accessories Revise
- Page 277 and 278: Power Mod Revised on 06/30/19 WMM R
- Page 279 and 280: Power Mod Revised on 06/30/19 WML a
Power Mod<br />
Revised on 06/30/19<br />
Type WMN ConEd Residential Meter Stacks<br />
Main Features:<br />
n 2-6 gang<br />
n 1200 amp horizontal<br />
bus rating<br />
n Suitable for 100k<br />
AIC applications<br />
3 METER<br />
CENTERS<br />
Residential 5-jaw ring type meter stacks; 3-phase, 4-wire SN, incoming and 1-phase, 3 wire SN outgoing c<br />
Outdoor<br />
Catalog<br />
number<br />
Indoor<br />
Catalog<br />
number<br />
Max. tenant breaker (Amps): 125<br />
Meter<br />
positions<br />
per stack<br />
WMN22125J MN22125J 2<br />
Breaker<br />
provision<br />
a Maximum<br />
Dimensions (inches)<br />
Knockout<br />
AIC Height Width Depth Diagram<br />
100k 35.31 12.97 8.09 WMN-1<br />
WMN32125J MN32125J 3 QP, QPH,<br />
100k 46.31 12.97 8.09 WMN-2<br />
WMN42125J MN42125J 4<br />
HQP, HQPH,<br />
MP-T, MP-HT,<br />
100k 56.31 12.97 8.09 WMN-3<br />
WMN52125J MN52125J 5 MPMT<br />
100k 66.31 12.97 8.09 WMN-4<br />
WMN62125J MN62125J 6 100k 76.31 12.97 8.09 WMN-5<br />
Max. tenant breaker (Amps): 225 b<br />
WMN22225J MN22225J 2<br />
100k 35.31 16.09 8.09 WMN-6<br />
WMN32225J<br />
WMN42225J<br />
WMN52225J<br />
MN32225J<br />
MN42225J<br />
MN52225J<br />
3<br />
4<br />
5<br />
QS, QSH, QSHH,<br />
HQS, HQSH,<br />
QP, QPH, HQP,<br />
HQPH, MP-T,<br />
MP-HT, MPMT<br />
100k<br />
100k<br />
100k<br />
46.31<br />
56.31<br />
66.31<br />
16.09<br />
16.09<br />
16.09<br />
8.09<br />
8.09<br />
8.09<br />
WMN-7<br />
WMN-8<br />
WMN-9<br />
WMN62225J MN62225J 6 100k 76.31 16.09 8.09 WMN-10<br />
Dimensions shown are representative of outside box<br />
dimensions and do not include allowances for mounting<br />
bumps, endwalls, covers, hubs, or hardware protrusions.<br />
Dimensions are subject to change.<br />
225A available in lower three positions only.<br />
200A continuous for all other positions.<br />
Must use QuickPhase features to route all sockets AWAY<br />
from high-leg when 240/120 Delta voltage is used.<br />
Max AIC determined by maximum AIC of tenant<br />
breakers.<br />
Install QP breakers below QS.<br />