Speedfax 2017

12.01.2021 Views

Group Metering: NYC Gangable Metering Terminals & Accessories 2 METER CENTERS Line Terminals (Use Specification Chart #5) Knowing the size and quantity per phase of the line conductors, select and spec these from Specification Chart #5. Line terminals come in kits of four terminal each. One kit will supply line terminals for three phase legs and neutral. End Walls (Use Specification Chart #6) NOTE: Each installation MUST have an end wall kit! The kit provides end walls for each end of the line and breaker troughs. (Four end walls). Use Specification Chart #6. Coupling Kits (Use Selection Chart #2 and Specification Chart #6) When more than one line trough is needed to support the number of meter stacks on a job, or when a line trough spacer is required, coupling straps are required to connect the troughs. Use Selection Chart #2 footnotes 3 and 4 to determine quantity of coupling kits required. Each kit provides one strap for line trough and one strap for breaker trough. Spec from Specification Chart #6. Line Trough Spacer Kits (Use Selection Chart #2 and Specification Chart #6) In some applications, the first phase block may be too close to the end wall of the line trough to provide proper wire bend space for the line conductors being used. Selection Chart #2 footnotes 1 and 2 will show when spacer kits are required. Tenant Circuit Breakers Each meter position in use requires a tenant circuit breaker. Use standard Murray Type MP-T circuit breakers from the Murray Catalog. Specification Chart #5—Line Terminals Wire Range Catalog Number (1) #6-350 kcmil ULK1350 (1) #4-500 kcmil or ULK1500 (2) #1/0-250 kcmil (2) #2-600 kcmil ULK2500 Specification Chart #6—End Wall and Coupling Kits Item End Wall Kit Contains 4 end walls; 2 for line trough and 2 for breaker trough. Coupling Kit Contains 2 coupling straps; 1 for line trough and 1 for breaker trough. Catalog Number UEW1216 UCP1216 Specification Chart #7—Accessories Item Spacer 10” spacer for use with line trough to provide wire bend space where required Meter Cover Blank Position Cover Plastic Meter Cover (Ring Type) Breaker Filler Plate Catalog Number ULT10SP UMCVR UMBCVR SX087M LX100FP 2-82 Siemens Industry, Inc. SPEEDFAX Product Catalog Product Category RESI

Power Mod and Uni-PAK SPEEDFAX TM Section Power Mod Meter Stack Uni-PAK Meter Center Power Mod is built upon service, quality, and flexibility Siemens Power Mod is a robust, flexible, and feature-rich line of modular metering designed to exceed today’s market demands. Power Mod’s exclusive QuickSystem has been proven to reduce labor by as much as 43% over comparable solutions while exclusive products such as the BFT Main Feed Thru family of mains, allow for lower material cost and incredible flexibility. Uni-PAK Metering offers maximum flexibility and ease of installation Siemens Uni-PAK Metering offers maximum flexibility and ease of installation to meet the service requirements of multiple position metering projects. The outdoor/indoor devices are available in two through six gang set-ups which consist of a pull section with main lugs or stud terminations, and 4/5 jaw meter sockets with tenant circuit breaker provisions. c o n t e n t s Power Mod Modular Metering 3-2 – 3-104 Overview of Power Mod Families 3-2 – 3-10 Configuration Tips and Applications 3-11 – 3-13 WB — Standard and Skinny Circuit Breaker Mains 3-14 – 3-19 WEB — Circuit Breaker Pullbox Combinations 3-20 – 3-23 WXB — Cross Bus Mains 3-24 – 3-26 WBT — Feed Thru Tap Box with Breaker 3-27 – 3-29 BFT — Main Feed Thru 3-30 – 3-32 WS — Standard Switch Mains 3-33 – 3-35 WES — Switch Pullbox Combinations 3-36 – 3-38 WXS — Cross Bus Switch Mains 3-39 – 3-41 WTB — Standard Tap boxes 3-42 – 3-45 WET — Tap box Pullbox Combinations 3-46 – 3-48 WT — Feed-Thru Tap boxes 3-49 – 3-51 WMM — Residential Meter Stacks 3-52 – 3-57 WML — Lever Bypass Meter Stacks 3-58 – 3-67 WMLZ — Fusible Residential Lever Bypass Meter Stacks 3-68 – 3-72 WMT — Test Block Bypass Meter Stacks 3-73 – 3-75 WMK — K-Base Meter Stacks 3-76 – 3-78 WC, WCL, WCT — House Power Modules 3-79 – 3-88 WSPD — Surge Protection Units 3-89 – 3-93 WMN — ConEd Residential Meter Stacks 3-94 – 3-96 WTBN — ConEd Tap boxes 3-98 – 3-100 WMMB — Aux Pull Box 3-101 – 3-102 Elbows and Spacers 3-103 – 3-104 3 METER CENTERS Scan to connect online to the most up-todate version of this Section of SPEEDFAX. Uni-PAK Meter Centers 3-105 – 3-127 Introduction 3-105 – 3-107 WP Ring Style Meter Centers 3-108 WP Ringless Style Meter Centers — No Bypass 3-109 WP Ringless Style Meter Centers — Horn Bypass 3-110 WEP EUSERC Ringstyle 3-111 WPL Ringless, Lever Bypass 3-112 Knockout Diagrams 3-113 – 3-127 Accessories and Replacement Parts 3-128 – 3-140 (Section was last modified on 11/20/20) Siemens Industry, Inc. SPEEDFAX Product Catalog 3-1

Group Metering: NYC Gangable Metering<br />

Terminals & Accessories<br />

2<br />

METER<br />

CENTERS<br />

Line Terminals<br />

(Use Specification Chart #5)<br />

Knowing the size and quantity per<br />

phase of the line conductors, select and<br />

spec these from Specification Chart #5.<br />

Line terminals come in kits of four terminal<br />

each. One kit will supply line terminals<br />

for three phase legs and neutral.<br />

End Walls<br />

(Use Specification Chart #6)<br />

NOTE: Each installation MUST have<br />

an end wall kit! The kit provides end<br />

walls for each end of the line and<br />

breaker troughs. (Four end walls). Use<br />

Specification Chart #6.<br />

Coupling Kits<br />

(Use Selection Chart #2 and<br />

Specification Chart #6)<br />

When more than one line trough is<br />

needed to support the number of<br />

meter stacks on a job, or when a line<br />

trough spacer is required, coupling<br />

straps are required to connect the<br />

troughs. Use Selection Chart #2 footnotes<br />

3 and 4 to determine quantity<br />

of coupling kits required. Each kit provides<br />

one strap for line trough and one<br />

strap for breaker trough. Spec from<br />

Specification Chart #6.<br />

Line Trough Spacer Kits<br />

(Use Selection Chart #2 and<br />

Specification Chart #6)<br />

In some applications, the first phase<br />

block may be too close to the end wall<br />

of the line trough to provide proper wire<br />

bend space for the line conductors being<br />

used. Selection Chart #2 footnotes 1<br />

and 2 will show when spacer kits are<br />

required.<br />

Tenant Circuit Breakers<br />

Each meter position in use requires a<br />

tenant circuit breaker. Use standard<br />

Murray Type MP-T circuit breakers from<br />

the Murray Catalog.<br />

Specification Chart #5—Line Terminals<br />

Wire Range<br />

Catalog Number<br />

(1) #6-350 kcmil ULK1350<br />

(1) #4-500 kcmil or<br />

ULK1500<br />

(2) #1/0-250 kcmil<br />

(2) #2-600 kcmil ULK2500<br />

Specification Chart #6—End Wall and Coupling Kits<br />

Item<br />

End Wall Kit<br />

Contains 4 end walls; 2 for line<br />

trough and 2 for breaker trough.<br />

Coupling Kit<br />

Contains 2 coupling straps; 1 for line<br />

trough and 1 for breaker trough.<br />

Catalog Number<br />

UEW1216<br />

UCP1216<br />

Specification Chart #7—Accessories<br />

Item<br />

Spacer<br />

10” spacer for use with line trough to<br />

provide wire bend space where required<br />

Meter Cover<br />

Blank Position Cover<br />

Plastic Meter Cover (Ring Type)<br />

Breaker Filler Plate<br />

Catalog Number<br />

ULT10SP<br />

UMCVR<br />

UMBCVR<br />

SX087M<br />

LX100FP<br />

2-82<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!