For Operation in the Control Cabinet 3RW Soft Starters Circuit Breaker SCCR Soft Starter Control Soft starters Q11 Type ToC 1 Rated current Circuit Brakers Thermal Magnetic Instantaneous Trip Fuse 480 V Type SCCR kA Max. size A 600 V Type SCCR kA Max. size A 480 V Type SCCR kA 3RW44 22 11 ED63B, 100 40 ED63A, 100 40 ED63A, 50 40 RK5 100 50 J 100 100 HEG3G HEM3M HEM3M 3RW44 23 23 ED63B, 100 50 ED63A, 100 50 ED63A, 50 50 RK5 100 60 J 100 120 HEG3G HEM3M HEM3M 3RW44 24 29 ED63B, 100 70 ED63A, 100 100 ED63A, 50 50 RK5 100 80 J 100 160 HEG3G HEM3M HEM3M 3RW44 25 29 ED63B, 100 70 ED63A, 100 50 ED63A, 50 50 RK5 100 80 HEG3G HEM3M HEM3M 3RW44 26 29 ED63B, 100 100 ED63A, 100 100 ED63A, 50 100 RK5 100 125 J 100 250 HEG3G HEM3M HEM3M 3RW44 27 34 FD63B 100 150 ED63A, 100 100 ED63A, 50 125 RK5 100 150 J 100 300 HEM3M HEM3M 3RW44 34 42 FD63B 100 150 FD63B 50 150 ED63A, 100 125 FXD63A 50 150 RK5 100 200 J 100 400 HEM3M 3RW44 35 58 FD63B 100 150 FD63B 50 150 FXD63A 100 150 FXD63A 50 150 RK5 100 200 J 100 400 3RW44 36 62 JD63B 100 200 JD63B 50 250 FXD63A 100 250 FXD63A 50 250 RK5 100 250 J 100 500 3RW44 43 73 JD63B 100 300 JD63B 50 250 FXD63A 100 250 JXD63A 50 300 RK5 100 300 J 100 600 3RW44 44 98 JD63B 100 300 JD63B 50 300 JXD63A 100 300 JXD63A 50 300 RK5 100 350 3RW44 45 98 JD63B 100 400 JD63B 50 400 JXD63A 100 400 JXD63A 50 400 RK5 100 450 3RW44 46 98 LD63B 100 500 LD63B 50 450 LXD63H 100 400 JXD63A 50 400 RK5 100 600 3RW44 47 98 LD63B 100 600 LD63B 50 600 LXD63H 100 600 LXD63H 50 600 L 100 700 3RW44 53 117 HMD6 65 800/ HMD6 50 800/ L 100 1000 800 800 3RW44 54 145 HND6 100 1200/ HND6 50 1200/ L 100 1000 900 900 3RW44 55 145 HND6 100 1200/ HND6 50 1200/ L 100 1000 900 900 3RW44 56 145 HND6 100 1200/ HND6 50 1200/ L 100 1000 1000 1000 3RW44 57 145 HND6 100 1200/ HND6 50 1200/ L 100 1000 1000 1000 3RW44 58 145 CND6 65 1200 CND6 65 1200 3RW44 65 205 CND6 42 1600 CND6 42 1600 3RW44 66 248 CND6 42 1600 CND6 42 1600 Max. size A 600 V Type SCCR kA Max. size A 600 V Type SCCR kA Max. size A 600 V Type SCCR kA Max. size A 17 CONTROL PRODUCTS Specified Type ED63A FXD63A JXD63A ED63B FD63B JD63B HND6 Others permitted HED63A, HHED63A or CED63A HFXD63A or CFD63A HJXD63A or CJD63A HED63B, HHED63B or CED63B HFD63B, HHFD63B or CFD63B HJ63B, HHJD63B or CJD63B HNXD6 or CND6 17-274 Siemens Industry, Inc. SPEEDFAX Product Catalog
For Operation in the Control Cabinet 3RW Soft Starters 3RW44 for high-feature applications Inline circuit fused version with 3NE1 SITOR all-range fuse (semiconductor and line protection) For matching fuse bases see Catalog LV 1 under "SENTRON Switching and Protection Devices for Power Distribution" ––> "Switch Disconnectors", and Catalog ET B1 under "BETA Protecting" ––> "SITOR Semiconductor Fuses" or go to www.siemens.com/sitor ––>"Products" ––>"BETA Protecting"––>"SITOR" Soft starters All-range fuses Line contactors up to 400 V 2 x 3NE1 435-2 560 690 +10 % 2 x 3NE1 435-2 560 690 +10 % 3 x 3NE1 334-2 500 690 +10 % 3 x 3NE1 435-2 560 690 +10 % 1) If the ramp-down function "Combined braking" is selected, no braking contactor is required. If the ramp-down function "DC braking" is selected, a braking contactor must be used in addition (see table for type). For applications with large centrifugal masses (J Load > J Motor ) we recommend the function "DC braking". Braking contactors 1)2) (for example circuit see page 17-261) ToC 2 Rated Rated current Voltage Size (optional) current Q11 F'1 Q21 Q91 Q92 Type A Type A V Type Type Type Type of coordination "2" 3) : I q = 65 kA 3RW44 22 29 3NE1 020-2 80 690 +5 % 00 3RT10 34 3RT15 26 -- 3RW44 23 36 3NE1 020-2 80 690 +5 % 00 3RT10 35 3RT15 26 -- 3RW44 24 47 3NE1 021-2 100 690 +5 % 00 3RT10 36 3RT15 35 -- 3RW44 25 57 3NE1 022-2 125 690 +5 % 00 3RT10 44 3RT15 35 -- 3RW44 26 77 3NE1 022-2 125 690 +5 % 00 3RT10 45 3RT10 24 3RT10 35 3RW44 27 93 3NE1 024-2 160 690 +5 % 1 3RT10 46 3RT10 25 3RT10 36 3RW44 34 113 3NE1 225-2 200 690 +5 % 1 3RT10 54 3RT10 34 3RT10 44 3RW44 35 134 3NE1 227-2 250 690 +5 % 1 3RT10 55 3RT10 36 3RT10 45 3RW44 36 162 3NE1 227-2 250 690 +5 % 1 3RT10 56 3RT10 44 3RT10 45 3RW44 43 203 3NE1 230-2 315 600 +10 % 1 3RT10 64 3RT10 44 3RT10 54 3RW44 44 250 3NE1 331-2 350 460 +10 % 2 3RT10 65 3RT10 44 3RT10 55 3RW44 45 313 3NE1 333-2 450 690 +5 % 2 3RT10 75 3RT10 54 3RT10 56 3RW44 46 356 3NE1 334-2 500 690 +5 % 2 3RT10 75 3RT10 54 3RT10 56 3RW44 47 432 3NE1 435-2 560 690 +5 % 3 3RT10 76 3RT10 55 3RT10 64 3RW44 53 551 2 x 3NE1 334-2 500 690 +10 % 2 3TF68 3RT10 64 3RT10 66 3RW44 54 615 2 x 3NE1 334-2 500 690 +10 % 2 3TF68 3RT10 64 3RT10 75 3RW44 55 693 2 x 3NE1 334-2 500 690 +10 % 2 3TF69 3RT10 65 3RT10 75 3RW44 56 780 2 x 3NE1 435-2 560 690 +10 % 3 3TF69 3RT10 65 3RT10 75 3RW44 57 880 6 3RW44 58 970 6 3RW44 65 1076 8 3RW44 66 1214 8 3 3RT10 75 3RT10 7 3 3RT10 75 3RT10 7 2 3RT10 75 3TF6 3 3RT10 76 3TF6 2) Additional auxiliary relay K4: LZX:RT4A4T30 (3RW44 soft starter with rated control supply voltage 230 V AC), LZX:RT4A4S15 (3RW44 soft starter with rated control supply voltage 115 V AC). 3) The type of coordination "2" refers only to soft starters in combination with the stipulated protective device (motor starter protector/circuit breaker/fuse), not to any additional components in the feeder. The types of coordination are explained under "3RA1 Fuseless Load Feeders". Soft Starter Control 17 CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX Product Catalog 17-275
- Page 1251 and 1252: For Operation in the Control Cabine
- Page 1253 and 1254: Control Products Enclosed 3RW44 3RW
- Page 1255 and 1256: Control Products Enclosed 3RW44 3RW
- Page 1257 and 1258: Control Products Enclosed 3RW44 3RW
- Page 1259 and 1260: Control Products Enclosed 3RW44 3RW
- Page 1261 and 1262: Control Products Enclosed 3RW44 Enc
- Page 1263 and 1264: For Operation in the Control Cabine
- Page 1265 and 1266: For Operation in the Control Cabine
- Page 1267 and 1268: For Operation in the Control Cabine
- Page 1269 and 1270: For Operation in the Control Cabine
- Page 1271 and 1272: For Operation in the Control Cabine
- Page 1273 and 1274: For Operation in the Control Cabine
- Page 1275 and 1276: For Operation in the Control Cabine
- Page 1277 and 1278: For Operation in the Control Cabine
- Page 1279 and 1280: For Operation in the Control Cabine
- Page 1281 and 1282: For Operation in the Control Cabine
- Page 1283 and 1284: For Operation in the Control Cabine
- Page 1285 and 1286: For Operation in the Control Cabine
- Page 1287 and 1288: For Operation in the Control Cabine
- Page 1289 and 1290: For Operation in the Control Cabine
- Page 1291 and 1292: For Operation in the Control Cabine
- Page 1293 and 1294: For Operation in the Control Cabine
- Page 1295 and 1296: For Operation in the Control Cabine
- Page 1297 and 1298: For Operation in the Control Cabine
- Page 1299 and 1300: For Operation in the Control Cabine
- Page 1301: For Operation in the Control Cabine
- Page 1305 and 1306: For Operation in the Control Cabine
- Page 1307 and 1308: For Operation in the Control Cabine
- Page 1309 and 1310: For Operation in the Control Cabine
- Page 1311 and 1312: l For Operation in the Control Cabi
- Page 1313 and 1314: 3RW44 5. and 3RW44 6. for High-Feat
- Page 1315 and 1316: For Operation in the Control Cabine
- Page 1317 and 1318: For Operation in the Control Cabine
- Page 1319 and 1320: For Operation in the Control Cabine
- Page 1321 and 1322: For Operation in the Control Cabine
- Page 1323 and 1324: Push SIRIUS Button ACT Pushbuttons
- Page 1325 and 1326: Pushbutton Units and Indicator Ligh
- Page 1327 and 1328: Push Buttons & Signaling Devices 30
- Page 1329 and 1330: Push Buttons & Signaling Devices 30
- Page 1331 and 1332: Push Buttons & Signaling Devices 30
- Page 1333 and 1334: Push Buttons & Signaling Devices 30
- Page 1335 and 1336: Push Buttons & Signaling Devices 30
- Page 1337 and 1338: Push Buttons & Signaling Devices 30
- Page 1339 and 1340: Push Buttons & Signaling Devices 30
- Page 1341 and 1342: Push Buttons & Signaling Devices 30
- Page 1343 and 1344: Push Buttons & Signaling Devices 30
- Page 1345 and 1346: Push Buttons & Signaling Devices 30
- Page 1347 and 1348: Pushbutton Units and Indicator Ligh
- Page 1349 and 1350: Pushbutton Units and Indicator Ligh
- Page 1351 and 1352: Pushbutton Units and Indicator Ligh
For Operation in the Control Cabinet<br />
3RW Soft Starters<br />
3RW44 for high-feature applications<br />
Inline circuit fused version with 3NE1 SITOR all-range fuse (semiconductor and line protection)<br />
For matching fuse bases see Catalog LV 1 under "SENTRON Switching and Protection Devices for Power<br />
Distribution" ––> "Switch Disconnectors", and Catalog ET B1 under "BETA Protecting" ––> "SITOR<br />
Semiconductor Fuses" or go to www.siemens.com/sitor ––>"Products" ––>"BETA Protecting"––>"SITOR"<br />
Soft starters All-range fuses Line contactors<br />
up to 400 V<br />
2 x 3NE1 435-2 560<br />
690 +10 %<br />
2 x 3NE1 435-2 560<br />
690 +10 %<br />
3 x 3NE1 334-2 500<br />
690 +10 %<br />
3 x 3NE1 435-2 560<br />
690 +10 %<br />
1) If the ramp-down function "Combined braking" is selected, no braking contactor<br />
is required.<br />
If the ramp-down function "DC braking" is selected, a braking contactor<br />
must be used in addition (see table for type).<br />
For applications with large centrifugal masses (J Load > J Motor ) we recommend<br />
the function "DC braking".<br />
Braking contactors 1)2)<br />
(for example circuit see page 17-261)<br />
ToC<br />
2 Rated<br />
Rated current Voltage Size (optional)<br />
current<br />
Q11 F'1 Q21 Q91 Q92<br />
Type A Type A V Type Type Type<br />
Type of coordination "2" 3) : I q = 65 kA<br />
3RW44 22 29 3NE1 020-2 80 690 +5 % 00 3RT10 34 3RT15 26 --<br />
3RW44 23 36 3NE1 020-2 80 690 +5 % 00 3RT10 35 3RT15 26 --<br />
3RW44 24 47 3NE1 021-2 100 690 +5 % 00 3RT10 36 3RT15 35 --<br />
3RW44 25 57 3NE1 022-2 125 690 +5 % 00 3RT10 44 3RT15 35 --<br />
3RW44 26 77 3NE1 022-2 125 690 +5 % 00 3RT10 45 3RT10 24 3RT10 35<br />
3RW44 27 93 3NE1 024-2 160 690 +5 % 1 3RT10 46 3RT10 25 3RT10 36<br />
3RW44 34 113 3NE1 225-2 200 690 +5 % 1 3RT10 54 3RT10 34 3RT10 44<br />
3RW44 35 134 3NE1 227-2 250 690 +5 % 1 3RT10 55 3RT10 36 3RT10 45<br />
3RW44 36 162 3NE1 227-2 250 690 +5 % 1 3RT10 56 3RT10 44 3RT10 45<br />
3RW44 43 203 3NE1 230-2 315 600 +10 % 1 3RT10 64 3RT10 44 3RT10 54<br />
3RW44 44 250 3NE1 331-2 350 460 +10 % 2 3RT10 65 3RT10 44 3RT10 55<br />
3RW44 45 313 3NE1 333-2 450 690 +5 % 2 3RT10 75 3RT10 54 3RT10 56<br />
3RW44 46 356 3NE1 334-2 500 690 +5 % 2 3RT10 75 3RT10 54 3RT10 56<br />
3RW44 47 432 3NE1 435-2 560 690 +5 % 3 3RT10 76 3RT10 55 3RT10 64<br />
3RW44 53 551 2 x 3NE1 334-2 500 690 +10 % 2 3TF68 3RT10 64 3RT10 66<br />
3RW44 54 615 2 x 3NE1 334-2 500 690 +10 % 2 3TF68 3RT10 64 3RT10 75<br />
3RW44 55 693 2 x 3NE1 334-2 500 690 +10 % 2 3TF69 3RT10 65 3RT10 75<br />
3RW44 56 780 2 x 3NE1 435-2 560 690 +10 % 3 3TF69 3RT10 65 3RT10 75<br />
3RW44 57 880 6<br />
3RW44 58 970 6<br />
3RW44 65 1076 8<br />
3RW44 66 1214 8<br />
3<br />
3RT10 75<br />
3RT10 7<br />
3<br />
3RT10 75<br />
3RT10 7<br />
2<br />
3RT10 75<br />
3TF6<br />
3<br />
3RT10 76<br />
3TF6<br />
2) Additional auxiliary relay K4:<br />
LZX:RT4A4T30<br />
(3RW44 soft starter with rated control supply voltage 230 V AC),<br />
LZX:RT4A4S15<br />
(3RW44 soft starter with rated control supply voltage 115 V AC).<br />
3) The type of coordination "2" refers only to soft starters in combination with<br />
the stipulated protective device (motor starter protector/circuit<br />
breaker/fuse), not to any additional components in the feeder.<br />
The types of coordination are explained under "3RA1 Fuseless Load<br />
Feeders".<br />
Soft Starter<br />
Control<br />
17 CONTROL<br />
PRODUCTS<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog 17-275