EUSERC Meter Mains<br />

EUSERC Side-By-Side Construction Meter Mains, 125A-400A<br />

EUSERC Meter Load Center Combinations<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14”<br />

Side-By-Side Side-By-Side 14”<br />

Side-By-Side 400A<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

2<br />

METER<br />

CENTERS<br />

n UL listed<br />

n For overhead and underground feed applications<br />

n Designed to meet EUSERC standards<br />

n 22,000 AIC Rated<br />

n Pad locking provisions on all devices<br />

n Surface and semi-flush units available - semi flush rails<br />

are depth adjustable for 2x6 studs<br />

n Side hinge door removable by backing out only one screw<br />

n Load wiring may exit top or bottom<br />

n Suitable for use only as service entrance equipment<br />

n RX type hub provision on top endwall, HC type hub<br />

provision on bottom endwall<br />

n 5th jaw accessory available (EMC5J)<br />

n Ring type meter covers<br />

n Contact local utility to confirm meter socket approval prior<br />

to installation<br />

n See end of section for 5th jaw and main breaker<br />

n See Section 2, pages 2-36 thru 2-50 for wiring diagrams<br />

and knockout details. For Murray devices, replace "MM"<br />

with "JC" details if JC number is not shown.<br />

Figure 1<br />

MM0202B1100ESC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Figure 2<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

JC0404L1400SC<br />

400A meter main<br />

EUSERC<br />

Side-By-Side 400A<br />

Side-By-Side Construction Meter Mains <br />

Amps No. of No. of Cover<br />

Old Catalog New Catalog Deminsions<br />

Max Spaces Circuits Type Mounting Service Bypass Type Number<br />

Number<br />

H W D<br />

125<br />

Flush<br />

JC0406L1125FEC MM0202L1125EFC<br />

2 2 Ring<br />

OH/UG none<br />

23.6 14.5 5<br />

125 Surface JC0406L1125SEC MM0202L1125ESC<br />

200<br />

Flush<br />

— MM0202L1200EFC<br />

7<br />

2 2 Ring<br />

OH/UG none<br />

28.6 14.5<br />

200 Surface JC0406L1200FEC MM0202L1200ESC 5<br />

100<br />

Surface<br />

JC0406L1200SEC MM0202B1100ESC 23.6<br />

2 2 Ring<br />

OH/UG none<br />

14.5 5<br />

200 Surface — MM0202B1200ESC 28.6<br />

Figure<br />

1<br />

Side-By-Side 400A Construction Meter Mains <br />

Amps No. of Max.<br />

Catalog<br />

Dimensions a<br />

Max. Spaces Circuits Mounting Service Number<br />

Height Width Depth<br />

400 4 2<br />

Surface OH/UG JC0404L1400SC d 33.2 6.4<br />

39.7<br />

Flush UG JC0404L1400FD d 30.2 7.4<br />

400 4 2<br />

Surface OH/UG JC0404L1400SCS cd 33.2 6.4<br />

39.7<br />

Flush UG JC0404L1400FDS cd 30.2 7.4<br />

Figure<br />

2<br />

2<br />

a Dimensions shown are representative of outside box<br />

length, width, and depth and do not include allowances<br />

for mounting bumps, endwalls, covers, hubs or hardware<br />

protrusions. Dimensions are subject to change.<br />

b Main breaker not included.<br />

c Test block bypass.<br />

d Main breaker: (2) Field QP(H) or QNR(H).<br />

No 5th Jaw available.<br />

Dimensional and other technical data is applicable<br />

for "New Catalog Numbers" ONLY.<br />

UL Listed for Siemens and Murray breakers.<br />

2-74<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

Product Category RESI