For Operation in the Control Cabinet<br />

3RW Soft Starters<br />

3RW30 for standard applications<br />

Standard Parameters<br />

Electromagnetic compatibility Acc. to EN 60947-4-2<br />

EMC interference immunity<br />

Electrostatic discharge (ESD) EN 61000-4-2 ±4 kV contact discharge, ±8 kV air discharge<br />

Electromagnetic RF fields EN 61000-4-3 Frequency range: 80 ... 2000 MHz with 80 % at 1 kHz<br />

Degree of severity 3: 10 V/m<br />

Conducted RF interference EN 61000-4-6 Frequency range: 150 kHz ... 80 MHz with 80 % at 1 kHz<br />

Interference 10 V<br />

RF voltages and RF currents on cables<br />

• Burst EN 61000-4-4 ±2 kV/5 kHz<br />

• Surge EN 61000-4-5 ±1 kV line to line<br />

±2 kV line to earth<br />

EMC interference emission<br />

EMC interference field strength EN 55011 Limit value of Class A at 30 ... 1000 MHz,<br />

limit value of Class B for 3RW30 2.; 24 V AC/DC<br />

Radio interference voltage EN 55011 Limit value of Class A at 0.15 ... 30 MHz,<br />

limit value of Class B for 3RW30 2.; 24 V AC/DC<br />

Radio interference suppression filters<br />

Degree of noise suppression A (industrial applications)<br />

Not required<br />

Degree of noise suppression B (applications for residential areas)<br />

Control voltage<br />

• 230 V AC/DC Not available 1)<br />

• 24 V AC/DC Not required for 3RW30 1. and 3RW30 2.;<br />

required for 3RW30 3. and 3RW30 4. (see Table)<br />

1) Degree of noise suppression B cannot be obtained through the use of<br />

filters as the strength of the electromagnetic field is not attenuated by the<br />

filter.<br />

Soft Starter<br />

Control<br />

Soft starter type Rated current Recommended filters 1)<br />

Soft starters Voltage range 200 ... 480 V<br />

Filter type Rated current filters Terminals<br />

A A mm 2<br />

3RW30 36 45 4EF1512-1AA10 50 16<br />

3RW30 37 63 4EF1512-2AA10 66 25<br />

3RW30 38 72 4EF1512-3AA10 90 25<br />

3RW30 46 80 4EF1512-3AA10 90 25<br />

3RW30 47 106 4EF1512-4AA10 120 50<br />

1) The radio interference suppression filter is used to remove the conducted<br />

interference from the main circuit. The field-related emissions comply with<br />

degree of noise suppression B. Filter selection applies under standard<br />

conditions: 10 starts per hour, start time 4 s at 300 % I e .<br />

Type Number Max. Fuse Class K5, RK5, RK1 Max. Fuse Class J Short Voltage Circuit Voltage<br />

Standard short circuit ratings 3RW30<br />

3RW30 13 -- 15 A 5 kA 480 V<br />

3RW30 14 -- 25 A 5 kA 480 V<br />

3RW30 16 -- 36 A 5 kA 480 V<br />

3RW30 17 -- 50 A 5 kA 480 V<br />

3RW30 18 -- 60 A 5 kA 480 V<br />

3RW30 26 100 A 100 A 5 kA 480 V<br />

3RW30 27 125 A 125 A 5 kA 480 V<br />

3RW30 28 125 A 125 A 5 kA 480 V<br />

3RW30 36 175 A 175 A 10 kA 480 V<br />

3RW30 37 250 A 250 A 10 kA 480 V<br />

3RW30 38 250 A 250 A 10 kA 480 V<br />

3RW30 46 -- 300 A 10 kA 480 V<br />

3RW30 47 -- 350 A 10 kA 480 V<br />

High capacity short circuit ratings 3RW30<br />

3RW30 13 -- 15 A 42 kA 480 V<br />

3RW30 14 -- 25 A 42 kA 480 V<br />

3RW30 16 -- 25 A 42 kA 480 V<br />

3RW30 17 -- 25 A 42 kA 480 V<br />

3RW30 18 -- 25 A 42 kA 480 V<br />

3RW30 26 60 A 100 A 42 kA 480 V<br />

3RW30 27 60 A 125 A 42 kA 480 V<br />

3RW30 28 60 A 125 A 42 kA 480 V<br />

3RW30 36 100 A 175 A 30 kA 480 V<br />

3RW30 37 100 A 200 A 30 kA 480 V<br />

3RW30 38 100 A 200 A 30 kA 480 V<br />

3RW30 46 110 A 200 A 42 kA 480 V<br />

3RW30 47 110 A 200 A 42 kA 480 V<br />

For solid-state motor controller, Type 3RW301: Applicable in an enclosure with minimum overall dimensions of 200 by 120 by 200 mm.<br />

For solid-state motor controller, Type 3RW302: Applicable in an enclosure with minimum overall dimensions of 370 by 175 by 195 mm.<br />

For solid-state motor controller, Type 3RW303: Applicable in an enclosure with minimum overall dimensions of 450 by 220 by 235 mm.<br />

For solid-state motor controller, Type 3RW304: Applicable in an enclosure with minimum overall dimensions of 450 by 220 by 235 mm.<br />