12.01.2021 Views

Speedfax 2017

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Meter Mains<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Meter Load Center Combinations<br />

Meter Mains, 100A-400A<br />

Side-By-Side<br />

Side-By-Side<br />

Over-Under Combo<br />

Over-Under<br />

Over-Under Combo<br />

Side-By-Side<br />

Over-Under<br />

Side-By-Side<br />

n UL listed<br />

n Pad locking provisions on all devices<br />

n Horn bypass and 5th jaw available as noted<br />

n Side hinged door with one screw removal where shown Side-By-Side<br />

n Suitable for use only as service entrance equipment<br />

n Contact local utility to confirm meter socket placement prior<br />

to installation<br />

n See end of section for 5th jaw and main breaker<br />

n See Section 2, pages 2-44 thru 2-46 for wiring diagrams and<br />

knockout details. For Murray devices, replace "MM" with<br />

"JC" details if JC number is not shown.<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Figure 2<br />

Meter Load Center Combinations<br />

Meter Mains<br />

Figure 3<br />

EUSERC Meter Mains<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Side-By-Side 400A<br />

Meter Mains<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

Meter Load Center Combinations<br />

Figure 4<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC Meter Mains<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

EUSERC<br />

Side-By-Side 400A<br />

EUSERC<br />

Meter Load Center Combinations<br />

Figure 1<br />

Over-Under Combo<br />

Side-By-Side Full Load Center<br />

Meter Mains<br />

Over-Under<br />

Side-By-Side<br />

JC0202B1125RJB<br />

meter mains, side hinge door<br />

Figure 5<br />

EUSERC<br />

Side-By-Side 400A<br />

Meter Load Center Combinations<br />

2 METER<br />

CENTERS<br />

Over-Under Combo<br />

Side-By-Side<br />

Over-Under<br />

Side-By-Side<br />

Over-Under Combo<br />

Side-By-Side<br />

Over-Under<br />

Side-By-Side<br />

Over-Under Combo<br />

EUSERC<br />

EUSERC<br />

Over-Under Over-Under 14” Side-By-Side<br />

14”<br />

Side-By-Side<br />

EUSERC<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Over-Under Combo<br />

Side-By-Side 400A<br />

Over-Under<br />

Side-By-Side<br />

EUSERC Meter Mains<br />

s<br />

EUSERC Meter Mains<br />

EUSERC Meter Mains<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Side-By-Side<br />

Side-By-Side 400A<br />

Side-By-Side 400A<br />

enter Combinations<br />

Combinations<br />

Side-By-Side<br />

JC0406L1200RHJB<br />

200A meter main, 6 circuits<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

Side-By-Side<br />

JC0404L1400RLM<br />

400A meter main, two field<br />

installed mains<br />

Side-By-Side 400A<br />

EUSERC Meter Load Center Combinations<br />

JC002CZ<br />

125A meter main<br />

EUSERC Meter Load Center Combinations<br />

EUSERC<br />

JC002CS<br />

meter main, OH feed only<br />

EUSERC<br />

EUSERC<br />

EUSERC<br />

Over-Under 14” Side-By-Side 14”<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A<br />

EUSERC<br />

Over-Under<br />

y-Side 14”<br />

EUSERC<br />

Side-By-Side<br />

Amps<br />

Max.<br />

Side-By-Side Full Load Center<br />

Side-By-Side Construction Meter Mains<br />

No. of<br />

Spaces<br />

EUSERC<br />

EUSERC<br />

Side-By-Side Over-Under 400A 14” Side-By-Side 14”<br />

EUSERC<br />

Max.<br />

Side-By-Side Full Load Center<br />

Circuits Cover Type Mounting Service<br />

EUSERC EUSERC<br />

EUSERC<br />

Side-By-Side Over-Under 400A 14” Side-By-Side 14”<br />

Bypass<br />

Type<br />

EUSERC<br />

Catalog<br />

Number<br />

Side-By-Side Full Load Center<br />

EUSERC<br />

Side-By-Side 400A<br />

Dimensions a<br />

Height Width Depth<br />

125 2 2 Ring Surface OH — JC002CZ b 14.1 14.1 4.6 4<br />

125 2 2 Ringless Surface OH/UG Horn JC0202B1125RJB c 17.0 16.0 5.0 1<br />

Ring<br />

— JC0202B1200 c<br />

200 2 2 Ringless Surface OH/UG — JC0202B1200R c<br />

17.0 16.0 5.0 1<br />

Ringless Horn JC0202B1200RJB c<br />

Ring<br />

— JC0406L1200H c<br />

200 4 6 Ringless Surface OH/UG — JC0406L1200RH c<br />

19.8 17.2 5.0 2<br />

Ringless Horn JC0406L1200RHJB c<br />

400 2 2 Ringless Surface OH/UG Lever JC0404L1400RLM c 29.0 27.0 6.0 3<br />

Figure<br />

Meter Load Center Combinations<br />

EUSERC<br />

Over-Under Side-By-Side Combo400A<br />

Over-Under<br />

Amps<br />

Max.<br />

Over-Under Construction Meter Mains<br />

Side-By-Side<br />

No. of<br />

Spaces<br />

Max.<br />

Circuits Cover Type Mounting Service<br />

Bypass<br />

Type<br />

Catalog<br />

Number<br />

Dimensions a<br />

Height Width Depth<br />

100 2 2 Ring Surface OH — JC002CS b 18.1 7.0 3.6 5<br />

125 2 2 Ring Surface OH — JC002AR b 22.1 7.0 3.6 5<br />

Figure<br />

0A<br />

inations<br />

a Dimensions shown are representative of outside box length,<br />

width, & depth and do not include allowances for mounting<br />

bumps, endwalls, covers, hubs or hardware protrusions.<br />

Dimensions are subject to change.<br />

b Not suitable for 5th jaw applications.<br />

c Closure plate included.<br />

Provisions for MP-T Main Breaker.<br />

EUSERC<br />

Product Category RESI<br />

EUSERC<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 2-71<br />

Side-By-Side Full Load Center<br />

Side-By-Side 400A