Speedfax 2017
For Operation in the Control Cabinet 3RW Soft Starters 3RW44 for high-feature applications CONTROL PRODUCTS 17 Soft Starter Control System Manual for SIRIUS 3RW44 Besides containing all important information on configuring, commissioning and servicing, the manual also contains example circuits and the technical specifications for all devices. This manual can be downloaded off the internet. Win-Soft Starter selection and simulation program With this software, you can simulate and select all Siemens soft starters, taking into account various parameters such as mains properties, motor and load data, and special application requirements. The software is a valuable tool, which makes complicated, lengthy manual calculations for determining the required soft starters superfluous. The Win-Soft Starter selection and simulation program can be downloaded free of charge from: www.usa.siemens.com/softstarters > Software More information can be found on the Internet at: www.usa.siemens.com/softstarters 17-220 Siemens Industry, Inc. SPEEDFAX Product Catalog
For Operation in the Control Cabinet 3RW Soft Starters Revised on 12/11/17 Soft starters for enclosed applications Overview The family of 3RW40 and 3RW44 softstarters are available in stand alone enclosed control designs for smooth starting and stopping of standard NEMA design B three phase inductive motors, thus eliminating physical stresses to the system and load while minimizing starting current. These pre-engineered enclosed designs offer convenience and flexibility in and UL/CSA certified offering. Enclosed styles are available in combination and non-combination configurations through 600HP and system voltages of 200V, 230V, 480V, and 600V. The Class 73 offers either the 3RW40 or 3RW44 in a non-combination style offering. These non-combination styles come standard with a choice of Type 1, 3R, 12, 4 NEMA rated enclosure, a control transformer, Sirius softstarter with built-in overload and bypass, line side power terminal block, and a reset pushbutton. The enclosed offering can be powerfully matched with a wide variety of factory modified options such as pushbutton control, pilot lights, metering and other control options such as isolation contactors and emergency start bypass starters. 3RW44 enclosed styles are also available with optional through the door keypad and Profibus communication. The Class 74 offering includes all of the features of the Class 73 in a combination style design. Standard options are either a circuit breaker or fusible disconnect providing short circuit protection and soft starting in one package. Application The Class 73/74 product is a fully enclosed solid state reduced voltage starter designed for a wide variety of industrial applications. The enclosed softstarter offerings are ideal for new as well as existing applications where total motor controls is required. Proper selection based on application data is made simple following these easy steps: - Select proper RVSS by application • Select the 3RW40 versus the 3RW44 using the application info provided in the open section of the catalog - Select the rating chart for normal starting or sever duty starting • Normal starting is rated at 350% of rated motor current IM for 10 seconds and based on starts per hour – representative of a class 20 application. • Severe starting is rated at 350% of rated motor current Im for 20 seconds and based on starts per hour – representative of a Class 20 application - Select model using Motor nameplate data • Identify correct motor voltage column • Select rate current or HP row • Find ordering number under desired enclosure type column (e.g. NEMA 1) • Select appropriate system voltage - Select factory modification on page 6/40 1) Example: 3RW44, N12, CB disconnect, 460V, 200HP with a start/stop and red run light Order No. 74MT34BFAP A1 FC Soft Starter Control Product Nomenclature Class 73 and 74 Enclosed Soft Starters Class 73 = Non-combination type 74 = Combination type Size + Model Rating (Amps) 3RW40 AR = 11 BR = 23 CR = 29 DR = 34 ER = 42 FR = 58 GR = 62 HR = 73 JR = 98 AS = 117 BS = 145 CS = 205 DS = 248 ES = 315 FS = 385 3RW44 AT = 26 BT = 32 CT = 42 DT = 51 ET = 68 FT = 82 GT = 100 HT = 117 JT = 145 KT = 180 LT = 215 MT = 280 NT = 315 PT = 385 QT = 494 RT = 551 ST = 615 TT = 693 WT = 780 YT = 970 ZT = 1076 Phases 3 = 3 phase Supply Voltage 6 = 200 2 = 230 3 = 380/415 4 = 460 5 = 575 Enclosure Type B = NEMA 1 0 = NEMA 12 D = NEMA 3R E = NEMA 4 W = NEMA 4X SS Mod Box Type F = Standard G = Modified Control Voltage A = None Disconnect Type Blank = None P = MCP T = Thermal Magnetic F = Fusible 17 CONTROL PRODUCTS 1) Some modifications will require a larger ‘Modified’ box than the standard box e.g. Isolation contactor, space heater, etc. See page 17-234 for instructions. Product Category: IEC Siemens Industry, Inc. SPEEDFAX Product Catalog 17-221
- Page 1197 and 1198: Standard & Irrigation Pump Panels C
- Page 1199 and 1200: Duplex Heavy Duty Controllers Class
- Page 1201 and 1202: Lighting and Heating Contactors Mec
- Page 1203 and 1204: 240V 230V 220V 480V 230V 460V 220V
- Page 1205 and 1206: Enclosed IEC Controls 3RE4 IEC Cont
- Page 1207 and 1208: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1209 and 1210: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1211 and 1212: Enclosed IEC Controls Selection Tab
- Page 1213 and 1214: Enclosed IEC Controls 3RE4 Factory
- Page 1215 and 1216: Enclosed IEC Controls 3RE4 Field Mo
- Page 1217 and 1218: Enclosed IEC Controls 3RE4 Outline
- Page 1219 and 1220: Enclosed IEC Controls 3RE4 Wiring D
- Page 1221 and 1222: Motor Starters, Soft Starters and L
- Page 1223 and 1224: For Operation in the Control Cabine
- Page 1225 and 1226: For Operation in the Control Cabine
- Page 1227 and 1228: For Operation in the Control Cabine
- Page 1229 and 1230: For Operation in the Control Cabine
- Page 1231 and 1232: Modules for RESET 1) Modules for re
- Page 1233 and 1234: For Operation in the Control Cabine
- Page 1235 and 1236: For Operation in the Control Cabine
- Page 1237 and 1238: For Operation in the Control Cabine
- Page 1239 and 1240: Planning and Configuration with SIR
- Page 1241 and 1242: Planning and Configuration with SIR
- Page 1243 and 1244: Planning and Configuration with SIR
- Page 1245 and 1246: For Operation in the Control Cabine
- Page 1247: For Operation in the Control Cabine
- Page 1251 and 1252: For Operation in the Control Cabine
- Page 1253 and 1254: Control Products Enclosed 3RW44 3RW
- Page 1255 and 1256: Control Products Enclosed 3RW44 3RW
- Page 1257 and 1258: Control Products Enclosed 3RW44 3RW
- Page 1259 and 1260: Control Products Enclosed 3RW44 3RW
- Page 1261 and 1262: Control Products Enclosed 3RW44 Enc
- Page 1263 and 1264: For Operation in the Control Cabine
- Page 1265 and 1266: For Operation in the Control Cabine
- Page 1267 and 1268: For Operation in the Control Cabine
- Page 1269 and 1270: For Operation in the Control Cabine
- Page 1271 and 1272: For Operation in the Control Cabine
- Page 1273 and 1274: For Operation in the Control Cabine
- Page 1275 and 1276: For Operation in the Control Cabine
- Page 1277 and 1278: For Operation in the Control Cabine
- Page 1279 and 1280: For Operation in the Control Cabine
- Page 1281 and 1282: For Operation in the Control Cabine
- Page 1283 and 1284: For Operation in the Control Cabine
- Page 1285 and 1286: For Operation in the Control Cabine
- Page 1287 and 1288: For Operation in the Control Cabine
- Page 1289 and 1290: For Operation in the Control Cabine
- Page 1291 and 1292: For Operation in the Control Cabine
- Page 1293 and 1294: For Operation in the Control Cabine
- Page 1295 and 1296: For Operation in the Control Cabine
- Page 1297 and 1298: For Operation in the Control Cabine
For Operation in the Control Cabinet<br />
3RW Soft Starters<br />
3RW44 for high-feature applications<br />
CONTROL<br />
PRODUCTS<br />
17<br />
Soft Starter<br />
Control<br />
System Manual for SIRIUS 3RW44<br />
Besides containing all important information on configuring,<br />
commissioning and servicing, the manual also contains example<br />
circuits and the technical specifications for all devices. This<br />
manual can be downloaded off the internet.<br />
Win-Soft Starter selection and simulation program<br />
With this software, you can simulate and select all Siemens soft<br />
starters, taking into account various parameters such as mains<br />
properties, motor and load data, and special application<br />
requirements.<br />
The software is a valuable tool, which makes complicated,<br />
lengthy manual calculations for determining the required soft<br />
starters superfluous.<br />
The Win-Soft Starter selection and simulation program can be<br />
downloaded free of charge from:<br />
www.usa.siemens.com/softstarters > Software<br />
More information can be found on the Internet at:<br />
www.usa.siemens.com/softstarters<br />
17-220<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog