For Operation in the Control Cabinet 3RW Soft Starters 3RW30 for standard applications Selection and ordering data Soft Starter Control 17 CONTROL PRODUCTS 3RW30 18-1BB14 3RW30 28-1BB14 3RW30 38-1BB14 3RW30 47-1BB14 3RW30 03-2CB54 Ambient temperature 40 °C Ambient temperature 50 °C Size Order No. List Rated Rated power of induction motors for rated operational current I operational voltage U e 1) e Rated Rated power of induction operational cur- voltage U e motors for rated operational 1) rent I e Price $ per PU PS* Weight per PU approx. 230 V 400 V 500 V 200 V 230 V 460 V 575 V A kW kW kW A hp hp hp hp Rated operational voltage U e 200 ... 480 V • With screw terminals 3.6 0.75 1.5 -- 3 0.5 0.5 1.5 -- S00 3RW30 13-1BB@4 1 unit 0.580 6.5 1.5 3 -- 4.8 1 1 3 -- S00 3RW30 14-1BB@4 1 unit 0.580 9 2.2 4 -- 7.8 2 2 5 -- S00 3RW30 16-1BB@4 1 unit 0.580 12.5 3 5.5 -- 11 3 3 7.5 -- S00 3RW30 17-1BB@4 1 unit 0.580 17.6 4 7.5 -- 17 3 3 10 -- S00 3RW30 18-1BB@4 1 unit 0.580 • With spring-type terminals 3.6 0.75 1.5 -- 3 0.5 0.5 1.5 -- S00 3RW30 13-2BB@4 1 unit 0.580 6.5 1.5 3 -- 4.8 1 1 3 -- S00 3RW30 14-2BB@4 1 unit 0.580 9 2.2 4 -- 7.8 2 2 5 -- S00 3RW30 16-2BB@4 1 unit 0.580 12.5 3 5.5 -- 11 3 3 7.5 -- S00 3RW30 17-2BB@4 1 unit 0.580 17.6 4 7.5 -- 17 3 3 10 -- S00 3RW30 18-2BB@4 1 unit 0.580 • With screw terminals 25 5.5 11 -- 23 5 5 15 -- S0 3RW30 26-1BB@4 1 unit 0.690 32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW30 27-1BB@4 1 unit 0.690 38 11 18.5 -- 34 10 10 25 -- S0 3RW30 28-1BB@4 1 unit 0.690 • With spring-type terminals 25 5.5 11 -- 23 5 5 15 -- S0 3RW30 26-2BB@4 1 unit 0.690 32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW30 27-2BB@4 1 unit 0.690 38 11 18.5 -- 34 10 10 25 -- S0 3RW30 28-2BB@4 1 unit 0.690 • With screw-type or spring-type terminals 45 11 22 -- 42 10 15 30 -- S2 3RW30 36-@BB@4 1 unit 1.200 63 18.5 30 -- 58 15 20 40 -- S2 3RW30 37-@BB@4 1 unit 1.200 72 22 37 -- 62 20 20 40 -- S2 3RW30 38-@BB@4 1 unit 1.200 • With screw-type or spring-type terminals 80 22 45 -- 73 20 25 50 -- S3 3RW30 46-@BB@4 1 unit 1.710 106 30 55 -- 98 30 30 75 -- S3 3RW30 47-@BB@4 1 unit 1.710 Order No. supplement for connection types • With screw terminals 1 • With spring-type terminals 2) 2 Order No. supplement for rated control supply voltage U s • 24 V AC/DC 0 • 110 ... 230 V 1 Soft starters for easy starting conditions and high switching frequency, rated operational voltage U e 200 ... 400 V, rated control supply voltage U s 24 ... 230 V AC/DC 3 0.55 1.1 -- 2.6 0.5 0.5 -- -- 22.5 mm • With screw terminals 3RW30 03-1CB54 1 unit 0.207 • With spring-type terminals 3RW30 03-2CB54 1 unit 0.188 1) Stand-alone installation. 2) Power connection: screw terminals. Note: Selection of the soft starter depends on the rated motor current. The SIRIUS 3RW30 solid-state soft starters are designed for easy starting conditions. J Load < 10 x J Motor . In the event of deviating conditions or increased switching frequency, it may be necessary to choose a larger device. Siemens recommends the use of the selection and simulation program Win-Soft Starter. For information about rated currents for ambient temperatures > 40 °C, see technical specifications (see technical information on page 17-235). 17-196 Siemens Industry, Inc. SPEEDFAX Product Catalog
For Operation in the Control Cabinet 3RW Soft Starters 3RW30 for standard applications Accessories For soft starters Motor starter protectors Order No. List Type Size Size Price $ per PU PS* Weight per PU approx . kg Auxiliary terminals Auxiliary terminals, 3-pole 3RW30 4. S3 3RT19 46-4F 1 unit 0.035 Covers for soft starters Terminal covers for box terminals Additional touch protection to be fitted at the box terminals (2 units required per device) 3RW30 3. S2 3RT19 36-4EA2 1 unit 0.020 3RW30 4. S3 3RT19 46-4EA2 1 unit 0.025 Terminal covers for cable lugs and busbar connections For complying with the phase clearances and as touch protection if box terminal is removed (2 units required per contactor) 3RW30 4. S3 3RT19 46-4EA1 1 unit 0.040 Link modules to motor starter protectors 3RW30 13, S00 S0 3RA19 21-1A 10 units 0.028 3RW30 14, 3RW30 16, 3RW30 17, 3RW30 18 3RW30 26 S0 S0 3RA19 21-1A 10 units 0.028 3RW30 36 S2 S2 3RA19 31-1A 5 units 0.033 3RW30 46, 3RW30 47 S3 S3 3RA19 41-1A 5 units 0.072 Soft Starter Control Operating instructions 1) For soft starters 3RW30 1. 3RW30 2. 3RW30 3. 3RW30 4. S00 S0 S2 S3 1) The operating instructions are included in the scope of supply. Version Functionality Functions Covers and push-in lugs (only for 3RW30 03) Sealable covers For securing against unauthorized adjustment of setting knobs Push-in lugs 3RP1 902 For screw fixing 3ZX10 12-0RW30-2DA1 Order No. List Price $ per PU Weight per PU approx. kg 3RP1 902 5 units 0.004 3RP1 903 10 units 0.002 17 CONTROL PRODUCTS 3RP1 903 Siemens Industry, Inc. SPEEDFAX Product Catalog 17-197
- Page 1173 and 1174: Reversing Heavy Duty Starters & Con
- Page 1175 and 1176: Combination Reversing Heavy Duty St
- Page 1177 and 1178: Combination Two Speed Heavy Duty St
- Page 1179 and 1180: Duplex Heavy Duty Controllers Class
- Page 1181 and 1182: Lighting Contactors Enclosed Contac
- Page 1183 and 1184: Manual Control Class 11 - 3RV, SMF,
- Page 1185 and 1186: Combination Heavy Duty Starters Cla
- Page 1187 and 1188: Combination Reversing Heavy Duty St
- Page 1189 and 1190: Two Speed Heavy Duty Starters Class
- Page 1191 and 1192: SEK SES SAW LMB SEK SES SAW LMB SEK
- Page 1193 and 1194: Reduced Voltage Starters & Pump Pan
- Page 1195 and 1196: Duplex Heavy Duty Controllers Class
- Page 1197 and 1198: Standard & Irrigation Pump Panels C
- Page 1199 and 1200: Duplex Heavy Duty Controllers Class
- Page 1201 and 1202: Lighting and Heating Contactors Mec
- Page 1203 and 1204: 240V 230V 220V 480V 230V 460V 220V
- Page 1205 and 1206: Enclosed IEC Controls 3RE4 IEC Cont
- Page 1207 and 1208: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1209 and 1210: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1211 and 1212: Enclosed IEC Controls Selection Tab
- Page 1213 and 1214: Enclosed IEC Controls 3RE4 Factory
- Page 1215 and 1216: Enclosed IEC Controls 3RE4 Field Mo
- Page 1217 and 1218: Enclosed IEC Controls 3RE4 Outline
- Page 1219 and 1220: Enclosed IEC Controls 3RE4 Wiring D
- Page 1221 and 1222: Motor Starters, Soft Starters and L
- Page 1223: For Operation in the Control Cabine
- Page 1227 and 1228: For Operation in the Control Cabine
- Page 1229 and 1230: For Operation in the Control Cabine
- Page 1231 and 1232: Modules for RESET 1) Modules for re
- Page 1233 and 1234: For Operation in the Control Cabine
- Page 1235 and 1236: For Operation in the Control Cabine
- Page 1237 and 1238: For Operation in the Control Cabine
- Page 1239 and 1240: Planning and Configuration with SIR
- Page 1241 and 1242: Planning and Configuration with SIR
- Page 1243 and 1244: Planning and Configuration with SIR
- Page 1245 and 1246: For Operation in the Control Cabine
- Page 1247 and 1248: For Operation in the Control Cabine
- Page 1249 and 1250: For Operation in the Control Cabine
- Page 1251 and 1252: For Operation in the Control Cabine
- Page 1253 and 1254: Control Products Enclosed 3RW44 3RW
- Page 1255 and 1256: Control Products Enclosed 3RW44 3RW
- Page 1257 and 1258: Control Products Enclosed 3RW44 3RW
- Page 1259 and 1260: Control Products Enclosed 3RW44 3RW
- Page 1261 and 1262: Control Products Enclosed 3RW44 Enc
- Page 1263 and 1264: For Operation in the Control Cabine
- Page 1265 and 1266: For Operation in the Control Cabine
- Page 1267 and 1268: For Operation in the Control Cabine
- Page 1269 and 1270: For Operation in the Control Cabine
- Page 1271 and 1272: For Operation in the Control Cabine
- Page 1273 and 1274: For Operation in the Control Cabine
For Operation in the Control Cabinet<br />
3RW Soft Starters<br />
3RW30 for standard applications<br />
Selection and ordering data<br />
Soft Starter<br />
Control<br />
17<br />
CONTROL<br />
PRODUCTS<br />
3RW30 18-1BB14 3RW30 28-1BB14 3RW30 38-1BB14 3RW30 47-1BB14 3RW30 03-2CB54<br />
Ambient temperature 40 °C Ambient temperature 50 °C Size Order No. List<br />
Rated Rated power of induction<br />
motors for rated<br />
operational<br />
current<br />
I<br />
operational voltage U e<br />
1)<br />
e<br />
Rated Rated power of induction<br />
operational<br />
cur-<br />
voltage U e<br />
motors for rated operational<br />
1)<br />
rent I e<br />
Price $<br />
per PU<br />
PS*<br />
Weight<br />
per PU<br />
approx.<br />
230 V 400 V 500 V 200 V 230 V 460 V 575 V<br />
A kW kW kW A hp hp hp hp<br />
Rated operational voltage U e 200 ... 480 V<br />
• With screw terminals<br />
3.6 0.75 1.5 -- 3 0.5 0.5 1.5 -- S00 3RW30 13-1BB@4 1 unit 0.580<br />
6.5 1.5 3 -- 4.8 1 1 3 -- S00 3RW30 14-1BB@4 1 unit 0.580<br />
9 2.2 4 -- 7.8 2 2 5 -- S00 3RW30 16-1BB@4 1 unit 0.580<br />
12.5 3 5.5 -- 11 3 3 7.5 -- S00 3RW30 17-1BB@4 1 unit 0.580<br />
17.6 4 7.5 -- 17 3 3 10 -- S00 3RW30 18-1BB@4 1 unit 0.580<br />
• With spring-type terminals<br />
3.6 0.75 1.5 -- 3 0.5 0.5 1.5 -- S00 3RW30 13-2BB@4 1 unit 0.580<br />
6.5 1.5 3 -- 4.8 1 1 3 -- S00 3RW30 14-2BB@4 1 unit 0.580<br />
9 2.2 4 -- 7.8 2 2 5 -- S00 3RW30 16-2BB@4 1 unit 0.580<br />
12.5 3 5.5 -- 11 3 3 7.5 -- S00 3RW30 17-2BB@4 1 unit 0.580<br />
17.6 4 7.5 -- 17 3 3 10 -- S00 3RW30 18-2BB@4 1 unit 0.580<br />
• With screw terminals<br />
25 5.5 11 -- 23 5 5 15 -- S0 3RW30 26-1BB@4 1 unit 0.690<br />
32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW30 27-1BB@4 1 unit 0.690<br />
38 11 18.5 -- 34 10 10 25 -- S0 3RW30 28-1BB@4 1 unit 0.690<br />
• With spring-type terminals<br />
25 5.5 11 -- 23 5 5 15 -- S0 3RW30 26-2BB@4 1 unit 0.690<br />
32 7.5 15 -- 29 7.5 7.5 20 -- S0 3RW30 27-2BB@4 1 unit 0.690<br />
38 11 18.5 -- 34 10 10 25 -- S0 3RW30 28-2BB@4 1 unit 0.690<br />
• With screw-type or spring-type terminals<br />
45 11 22 -- 42 10 15 30 -- S2 3RW30 36-@BB@4 1 unit 1.200<br />
63 18.5 30 -- 58 15 20 40 -- S2 3RW30 37-@BB@4 1 unit 1.200<br />
72 22 37 -- 62 20 20 40 -- S2 3RW30 38-@BB@4 1 unit 1.200<br />
• With screw-type or spring-type terminals<br />
80 22 45 -- 73 20 25 50 -- S3 3RW30 46-@BB@4 1 unit 1.710<br />
106 30 55 -- 98 30 30 75 -- S3 3RW30 47-@BB@4 1 unit 1.710<br />
Order No. supplement for connection types<br />
• With screw terminals 1<br />
• With spring-type terminals 2) 2<br />
Order No. supplement for rated control supply voltage U s<br />
• 24 V AC/DC 0<br />
• 110 ... 230 V 1<br />
Soft starters for easy starting conditions and high switching frequency,<br />
rated operational voltage U e 200 ... 400 V,<br />
rated control supply voltage U s 24 ... 230 V AC/DC<br />
3 0.55 1.1 -- 2.6 0.5 0.5 -- -- 22.5 mm<br />
• With screw terminals 3RW30 03-1CB54 1 unit 0.207<br />
• With spring-type terminals 3RW30 03-2CB54 1 unit 0.188<br />
1) Stand-alone installation.<br />
2) Power connection: screw terminals.<br />
Note:<br />
Selection of the soft starter depends on the rated motor current.<br />
The SIRIUS 3RW30 solid-state soft starters are designed for<br />
easy starting conditions. J Load < 10 x J Motor . In the event of<br />
deviating conditions or increased switching frequency, it may be<br />
necessary to choose a larger device.<br />
Siemens recommends the use of the selection and simulation<br />
program Win-Soft Starter. For information about rated currents<br />
for ambient temperatures > 40 °C, see technical specifications<br />
(see technical information on page 17-235).<br />
17-196<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog