Enclosed IEC Controls 3RE4 Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay Revised on 05/31/19 Selection Ordering Information Replace the (●) with the code from the coil table on this page. Replace the () with the overload relay (OLR) code from this page. Replace the (♦♦) with the OLR current adjustment range from pg. 17-216. For factory modifications, see page 17-217 – 17-218. For accessories, see page 17-220 – 17-262. For replacement parts, see page 17-262. For dimensions, see page 17-281. For wiring diagrams, see page 17-284 – 17-290. Coil Selection (●) a Nominal Voltage Code 24 VAC 50/60 Hz 1 24 VDC 2 110/120 VAC 50/60 Hz 3 208 VAC 50/60 Hz 4 220/240 VAC 50/60 Hz 5 277 VAC 60 Hz 6 480 VAC 60 Hz 7 600 VAC 60 Hz 8 Soft Starter Control 17 CONTROL PRODUCTS Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay, Standard Enclosure 3-Phase Motor Hp Rating per UL NEMA Type Enclosure (Standard Size) Type 1 General Purpose, Indoor only Type 3/3R/4/12 Weatherproof, Watertight, Dust-tight Type 4X 304 Stain. Steel Watertight, Dust-tight, Corrosion Resistant Unused Auxiliary Contacts Frame Size Contactor (for ref. only) 208 V 230 V 460 V 575 V Catalog Number Catalog Number Catalog Number NO NC 1.5 2 3 5 3RE4141–5AA●–♦♦Y0 3RE4141–5CA●–♦♦Y0 3RE4141–5EA●–♦♦Y0 2 2 S00 3RA2315 2 3 5 7.5 3RE4142–3AA●–♦♦Y0 3RE4142–3CA●–♦♦Y0 3RE4142–3EA●–♦♦Y0 2 0 S0 3RA2323 3 3 7.5 10 3RE4142–4AA●–♦♦Y0 3RE4142–4CA●–♦♦Y0 3RE4142–4EA●–♦♦Y0 2 0 S0 3RA2324 5 5 10 15 3RE4142–5AA●–♦♦Y0 3RE4142–5CA●–♦♦Y0 3RE4142–5EA●–♦♦Y0 2 0 S0 3RA2325 7.5 7.5 15 20 3RE4142–6AA●–♦♦Y0 3RE4142–6CA●–♦♦Y0 3RE4142–6EA●–♦♦Y0 2 0 S0 3RA2326 10 10 20 25 3RE4142–7AA●–♦♦Y0 3RE4142–7CA●–♦♦Y0 3RE4142–7EA●–♦♦Y0 2 0 S0 3RA2327 10 10 25 25 3RE4142–8AA●–♦♦Y0 3RE4142–8CA●–♦♦Y0 3RE4142–8EA●–♦♦Y0 2 0 S0 3RA2328 10 15 30 40 3RE4143–5AA●–♦♦Y0 3RE4143–5CA●–♦♦Y0 3RE4143–5EA●–♦♦Y0 2 0 S2 3RA2335 15 15 40 50 3RE4143–6AA●–♦♦Y0 3RE4143–6CA●–♦♦Y0 3RE4143–6EA●–♦♦Y0 2 0 S2 3RA2336 20 20 50 50 3RE4143–7AA●–♦♦Y0 3RE4143–7CA●–♦♦Y0 3RE4143–7EA●–♦♦Y0 2 0 S2 3RA2337 20 25 50 60 3RE4143–8AA●–♦♦Y0 3RE4143–8CA●–♦♦Y0 3RE4143–8EA●–♦♦Y0 2 0 S2 3RA2338 Thermal overload relay Class 10 = 1 Solid-state overload relay selectable Class = 5 Reversing Starter, 3-Phase, 3-Pole, Thermal or Solid-State Overload Relay, Large Enclosure 3-Phase Motor Hp Rating per UL NEMA Type Enclosure (Large Size) Type 1 General Purpose, Indoor only 1 5 Type 3/3R/4/12 Weatherproof, Watertight, Dust-tight 1 5 Type 4X 304 Stain. Steel Watertight, Dust-tight, Corrosion Resistant Unused Auxiliary Contacts Frame Size Contactor (for ref. only) 208 V 230 V 460 V 575 V Catalog Number Catalog Number Catalog Number NO NC 1.5 2 3 5 3RE4141–5BA●–♦♦Y0 2 2 S00 3RA2315 2 3 5 7.5 3RE4142–3BA●–♦♦Y0 2 0 S0 3RA2323 3 3 7.5 10 3RE4142–4BA●–♦♦Y0 2 0 S0 3RA2324 5 5 10 15 3RE4142–5BA●–♦♦Y0 Not applicable — Standard enclosure includes 2 0 S0 3RA2325 extra mounting space for accessories. 7.5 7.5 15 20 3RE4142–6BA●–♦♦Y0 2 0 S0 3RA2326 10 10 20 25 3RE4142–7BA●–♦♦Y0 2 0 S0 3RA2327 10 10 25 25 3RE4142–8BA●–♦♦Y0 2 0 S0 3RA2328 Thermal overload relay Class 10 = 1 Solid-state overload relay selectable Class = 5 a For 3-phase controllers, 208 - 600 V coils will be wired for incoming voltage. 24 and120 V coils will be wired as separate source or control power transformer secondary (if ordered). For single phase controllers, 120 and 240 V coils will be wired for incoming voltage. 24 V coils will be wired as separate source or control power transformer secondary (if ordered). 277 - 600 V coils do not apply. 17-180 Siemens Industry, Inc. SPEEDFAX Product Catalog
Enclosed IEC Controls 3RE4 Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase) Revised on 05/31/19 Selection Ordering Information Replace the (●) with the code from the coil table on this page. For factory modifications, see page 17-217 – 17-218. For accessories, see page 17-220 – 17-262. For replacement parts, see page 17-262. For dimensions, see page 17-281. For wiring diagrams, see page 17-284 – 17-290. Coil Selection (●) a Nominal Voltage Code 24 VAC 50/60 Hz 1 24 VDC 2 110/120 VAC 50/60 Hz 3 208 VAC 50/60 Hz 4 220/240 VAC 50/60 Hz 5 277 VAC 60 Hz 6 480 VAC 60 Hz 7 600 VAC 60 Hz 8 Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase), Standard Enclosure 1-Phase Motor Hp Rating per UL 3-Phase Motor Hp Rating per UL NEMA Type Enclosure (Standard Size) Type 1 General Purpose, Indoor only Type 3/3R/4/12 Weatherproof, Watertight, Dust-tight Type 4X 304 Stain. Steel Watertight, Dust-tight, Corrosion Resistant Unused Auxiliary Contacts Frame Size Contactor (for ref. only) 115V 208V 230V 208V 230V 460V 575V Catalog Number Catalog Number Catalog Number NO NC 0.25 0.5 0.75 1.5 2 3 5 3RE4161–5AA●0–0YY0 3RE4161–5CA●0–0YY0 3RE4161–5EA●0–0YY0 1 0 S00 3RT2015 1 1 1 2 3 5 7.5 3RE4162–3AA●0–0YY0 3RE4162–3CA●0–0YY0 3RE4162–3EA●0–0YY0 1 1 S0 3RT2023 1 2 2 3 3 7.5 10 3RE4162–4AA●0–0YY0 3RE4162–4CA●0–0YY0 3RE4162–4EA●0–0YY0 1 1 S0 3RT2024 1 2 3 5 5 10 15 3RE4162–5AA●0–0YY0 3RE4162–5CA●0–0YY0 3RE4162–5EA●0–0YY0 1 1 S0 3RT2025 2 3 3 7.5 7.5 15 20 3RE4162–6AA●0–0YY0 3RE4162–6CA●0–0YY0 3RE4162–6EA●0–0YY0 1 1 S0 3RT2026 2 5 5 10 10 20 25 3RE4162–7AA●0–0YY0 3RE4162–7CA●0–0YY0 3RE4162–7EA●0–0YY0 1 1 S0 3RT2027 3 5 5 10 10 25 25 3RE4162–8AA●0–0YY0 3RE4162–8CA●0–0YY0 3RE4162–8EA●0–0YY0 1 1 S0 3RT2028 3 5 7.5 10 15 30 40 3RE4163–5AA●0–0YY0 3RE4163–5CA●0–0YY0 3RE4163–5EA●0–0YY0 1 1 S2 3RT2035 3 7 10 15 15 40 50 3RE4163–6AA●0–0YY0 3RE4163–6CA●0–0YY0 3RE4163–6EA●0–0YY0 1 1 S2 3RT2036 5 10 10 20 20 50 50 3RE4163–7AA●0–0YY0 3RE4163–7CA●0–0YY0 3RE4163–7EA●0–0YY0 1 1 S2 3RT2037 5 10 15 20 25 50 60 3RE4163–8AA●0–0YY0 3RE4163–8CA●0–0YY0 3RE4163–8EA●0–0YY0 1 1 S2 3RT2038 Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase), Large Enclosure 1-Phase Motor Hp Rating per UL 3-Phase Motor Hp Rating per UL NEMA Type Enclosure (Large Size) Type 1 General Purpose, Indoor only Type 3/3R/4/12 Weatherproof, Watertight, Dust-tight Type 4X 304 Stain. Steel Watertight, Dust-tight, Corrosion Resistant Unused Auxiliary Contacts Frame Size Contactor (for ref. only) 115V 208V 230V 208V 230V 460V 575V Catalog Number Catalog Number Catalog Number NO NC 0.25 0.5 0.75 1.5 2 3 5 3RE4161–5BA●0–0YY0 1 0 S00 3RT2015 1 1 1 2 3 5 7.5 3RE4162–3BA●0–0YY0 1 1 S0 3RT2023 1 2 2 3 3 7.5 10 3RE4162–4BA●0–0YY0 1 1 S0 3RT2024 1 2 3 5 5 10 15 3RE4162–5BA●0–0YY0 Not applicable — Standard enclosure includes 1 1 S0 3RT2025 extra mounting space for accessories. 2 3 3 7.5 7.5 15 20 3RE4162–6BA●0–0YY0 1 1 S0 3RT2026 2 5 5 10 10 20 25 3RE4162–7BA●0–0YY0 1 1 S0 3RT2027 3 5 5 10 10 25 25 3RE4162–8BA●0–0YY0 1 1 S0 3RT2028 Soft Starter Control 17 CONTROL PRODUCTS a For 3-phase controllers, 208 - 600 V coils will be wired for incoming voltage. 24 and120 V coils will be wired as separate source or control power transformer secondary (if ordered). For single phase controllers, 120 and 240 V coils will be wired for incoming voltage. 24 V coils will be wired as separate source or control power transformer secondary (if ordered). 277 - 600 V coils do not apply. Siemens Industry, Inc. SPEEDFAX Product Catalog 17-181
- Page 1157 and 1158: Heavy Duty Motor Starters Solid Sta
- Page 1159 and 1160: Heavy Duty Contactors Class 40 Dime
- Page 1161 and 1162: Overload Relays & Current Transform
- Page 1163 and 1164: Lighting & Heating Contactors Open
- Page 1165 and 1166: GROUND 1/ L1 3/ L2 5/ L3 2/ T1 11 2
- Page 1167 and 1168: Lighting & Heating Contactors Mecha
- Page 1169 and 1170: Heavy Duty Motor Starters & Contact
- Page 1171 and 1172: Combination Heavy Duty Starters Enc
- Page 1173 and 1174: Reversing Heavy Duty Starters & Con
- Page 1175 and 1176: Combination Reversing Heavy Duty St
- Page 1177 and 1178: Combination Two Speed Heavy Duty St
- Page 1179 and 1180: Duplex Heavy Duty Controllers Class
- Page 1181 and 1182: Lighting Contactors Enclosed Contac
- Page 1183 and 1184: Manual Control Class 11 - 3RV, SMF,
- Page 1185 and 1186: Combination Heavy Duty Starters Cla
- Page 1187 and 1188: Combination Reversing Heavy Duty St
- Page 1189 and 1190: Two Speed Heavy Duty Starters Class
- Page 1191 and 1192: SEK SES SAW LMB SEK SES SAW LMB SEK
- Page 1193 and 1194: Reduced Voltage Starters & Pump Pan
- Page 1195 and 1196: Duplex Heavy Duty Controllers Class
- Page 1197 and 1198: Standard & Irrigation Pump Panels C
- Page 1199 and 1200: Duplex Heavy Duty Controllers Class
- Page 1201 and 1202: Lighting and Heating Contactors Mec
- Page 1203 and 1204: 240V 230V 220V 480V 230V 460V 220V
- Page 1205 and 1206: Enclosed IEC Controls 3RE4 IEC Cont
- Page 1207: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1211 and 1212: Enclosed IEC Controls Selection Tab
- Page 1213 and 1214: Enclosed IEC Controls 3RE4 Factory
- Page 1215 and 1216: Enclosed IEC Controls 3RE4 Field Mo
- Page 1217 and 1218: Enclosed IEC Controls 3RE4 Outline
- Page 1219 and 1220: Enclosed IEC Controls 3RE4 Wiring D
- Page 1221 and 1222: Motor Starters, Soft Starters and L
- Page 1223 and 1224: For Operation in the Control Cabine
- Page 1225 and 1226: For Operation in the Control Cabine
- Page 1227 and 1228: For Operation in the Control Cabine
- Page 1229 and 1230: For Operation in the Control Cabine
- Page 1231 and 1232: Modules for RESET 1) Modules for re
- Page 1233 and 1234: For Operation in the Control Cabine
- Page 1235 and 1236: For Operation in the Control Cabine
- Page 1237 and 1238: For Operation in the Control Cabine
- Page 1239 and 1240: Planning and Configuration with SIR
- Page 1241 and 1242: Planning and Configuration with SIR
- Page 1243 and 1244: Planning and Configuration with SIR
- Page 1245 and 1246: For Operation in the Control Cabine
- Page 1247 and 1248: For Operation in the Control Cabine
- Page 1249 and 1250: For Operation in the Control Cabine
- Page 1251 and 1252: For Operation in the Control Cabine
- Page 1253 and 1254: Control Products Enclosed 3RW44 3RW
- Page 1255 and 1256: Control Products Enclosed 3RW44 3RW
- Page 1257 and 1258: Control Products Enclosed 3RW44 3RW
Enclosed IEC Controls<br />
3RE4 Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase)<br />
Revised on 05/31/19<br />
Selection<br />
Ordering Information<br />
Replace the (●) with the code from the coil<br />
table on this page.<br />
For factory modifications,<br />
see page 17-217 – 17-218.<br />
For accessories, see page 17-220 – 17-262.<br />
For replacement parts, see page 17-262.<br />
For dimensions, see page 17-281.<br />
For wiring diagrams, see page 17-284 – 17-290.<br />
Coil Selection (●) a<br />
Nominal Voltage<br />
Code<br />
24 VAC 50/60 Hz 1<br />
24 VDC 2<br />
110/120 VAC 50/60 Hz 3<br />
208 VAC 50/60 Hz 4<br />
220/240 VAC 50/60 Hz 5<br />
277 VAC 60 Hz 6<br />
480 VAC 60 Hz 7<br />
600 VAC 60 Hz 8<br />
Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase), Standard Enclosure<br />
1-Phase Motor Hp<br />
Rating per UL<br />
3-Phase Motor Hp<br />
Rating per UL<br />
NEMA Type Enclosure (Standard Size)<br />
Type 1<br />
General Purpose,<br />
Indoor only<br />
Type 3/3R/4/12<br />
Weatherproof,<br />
Watertight, Dust-tight<br />
Type 4X 304 Stain. Steel<br />
Watertight, Dust-tight,<br />
Corrosion Resistant<br />
Unused<br />
Auxiliary<br />
Contacts Frame<br />
Size<br />
Contactor<br />
(for ref.<br />
only)<br />
115V 208V 230V 208V 230V 460V 575V Catalog Number Catalog Number Catalog Number NO NC<br />
0.25 0.5 0.75 1.5 2 3 5 3RE4161–5AA●0–0YY0 3RE4161–5CA●0–0YY0 3RE4161–5EA●0–0YY0 1 0 S00 3RT2015<br />
1 1 1 2 3 5 7.5 3RE4162–3AA●0–0YY0 3RE4162–3CA●0–0YY0 3RE4162–3EA●0–0YY0 1 1 S0 3RT2023<br />
1 2 2 3 3 7.5 10 3RE4162–4AA●0–0YY0 3RE4162–4CA●0–0YY0 3RE4162–4EA●0–0YY0 1 1 S0 3RT2024<br />
1 2 3 5 5 10 15 3RE4162–5AA●0–0YY0 3RE4162–5CA●0–0YY0 3RE4162–5EA●0–0YY0 1 1 S0 3RT2025<br />
2 3 3 7.5 7.5 15 20 3RE4162–6AA●0–0YY0 3RE4162–6CA●0–0YY0 3RE4162–6EA●0–0YY0 1 1 S0 3RT2026<br />
2 5 5 10 10 20 25 3RE4162–7AA●0–0YY0 3RE4162–7CA●0–0YY0 3RE4162–7EA●0–0YY0 1 1 S0 3RT2027<br />
3 5 5 10 10 25 25 3RE4162–8AA●0–0YY0 3RE4162–8CA●0–0YY0 3RE4162–8EA●0–0YY0 1 1 S0 3RT2028<br />
3 5 7.5 10 15 30 40 3RE4163–5AA●0–0YY0 3RE4163–5CA●0–0YY0 3RE4163–5EA●0–0YY0 1 1 S2 3RT2035<br />
3 7 10 15 15 40 50 3RE4163–6AA●0–0YY0 3RE4163–6CA●0–0YY0 3RE4163–6EA●0–0YY0 1 1 S2 3RT2036<br />
5 10 10 20 20 50 50 3RE4163–7AA●0–0YY0 3RE4163–7CA●0–0YY0 3RE4163–7EA●0–0YY0 1 1 S2 3RT2037<br />
5 10 15 20 25 50 60 3RE4163–8AA●0–0YY0 3RE4163–8CA●0–0YY0 3RE4163–8EA●0–0YY0 1 1 S2 3RT2038<br />
Non-Reversing Contactor, 3-Pole (for both 1-Phase and 3-Phase), Large Enclosure<br />
1-Phase Motor Hp<br />
Rating per UL<br />
3-Phase Motor Hp<br />
Rating per UL<br />
NEMA Type Enclosure (Large Size)<br />
Type 1<br />
General Purpose,<br />
Indoor only<br />
Type 3/3R/4/12<br />
Weatherproof,<br />
Watertight, Dust-tight<br />
Type 4X 304 Stain. Steel<br />
Watertight, Dust-tight,<br />
Corrosion Resistant<br />
Unused<br />
Auxiliary<br />
Contacts<br />
Frame<br />
Size<br />
Contactor<br />
(for ref.<br />
only)<br />
115V 208V 230V 208V 230V 460V 575V Catalog Number Catalog Number Catalog Number NO NC<br />
0.25 0.5 0.75 1.5 2 3 5 3RE4161–5BA●0–0YY0<br />
1 0 S00 3RT2015<br />
1 1 1 2 3 5 7.5 3RE4162–3BA●0–0YY0 1 1 S0 3RT2023<br />
1 2 2 3 3 7.5 10 3RE4162–4BA●0–0YY0 1 1 S0 3RT2024<br />
1 2 3 5 5 10 15 3RE4162–5BA●0–0YY0<br />
Not applicable — Standard enclosure includes<br />
1 1 S0 3RT2025<br />
extra mounting space for accessories.<br />
2 3 3 7.5 7.5 15 20 3RE4162–6BA●0–0YY0 1 1 S0 3RT2026<br />
2 5 5 10 10 20 25 3RE4162–7BA●0–0YY0 1 1 S0 3RT2027<br />
3 5 5 10 10 25 25 3RE4162–8BA●0–0YY0 1 1 S0 3RT2028<br />
Soft Starter<br />
Control<br />
17 CONTROL<br />
PRODUCTS<br />
a For 3-phase controllers, 208 - 600 V coils will be wired<br />
for incoming voltage. 24 and120 V coils will be wired<br />
as separate source or control power transformer<br />
secondary (if ordered). For single phase controllers,<br />
120 and 240 V coils will be wired for incoming voltage.<br />
24 V coils will be wired as separate source or control<br />
power transformer secondary (if ordered). 277 - 600 V<br />
coils do not apply.<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog 17-181