Speedfax 2017
Duplex Heavy Duty Controllers Class LC and LE Electrically Held Contactors Revised on 03/31/20 Wiring Diagrams LEN00B003 (20A 3 Pole) A1 1 /L1 3 /L2 5 L3 13 LEN00F003 (200A 3 Pole) LEN00G003 (300A 3 Pole) LEN00H003 (400A 3 Pole) A1 1 /L1 3 /L2 5 /L3 13 21 31 43 U A2 2 /T1 4 /T2 6 /T3 14 A2 2 /T1 4 /T2 6 /T3 14 22 32 44 LEN00B004 (20A 4 Pole) A1 1 /L1 3 /L2 5 /L3 7 /L4 LCE00C (30A 2-12 Pole) LINE 1 LOAD A2 2 /T1 4 /T2 6 /T3 8 /T4 2 3 NEMA & General Purpose Control LEN00C003 (30A 3 Pole) LEN00D003 (60A 3 Pole) LEN00E003 (100A 3 Pole) A1 1 /L1 3 /L2 5 /L3 13 21 4 5 6 A1 COIL A2 17 A2 2 /T1 4 /T2 6 /T3 14 22 COIL VOLTAGE CONTROL PRODUCTS LEN00C004 (30A 4 Pole) A1 1 /L1 3 /L2 5 /L3 7 /L4 13 21 OPTIONAL AUXILIARY CONTACTS A2 2 /T1 4 /T2 6 /T3 8 /T4 14 22 17-170 Siemens Industry, Inc. SPEEDFAX Product Catalog
Duplex Heavy Duty Controllers Class LC and LE Electrically Held Contactors Wiring Diagrams Optional Pilot Devices for Electrically Held Contactor OFF PB ON PB ON ON and OFF Push buttons L1 FUSE * A2 COIL A1 FUSE * L2 REMOTE OFF AUXILIARY CONTACT REMOTE ON AUXILIARY CONTACT OFF OFF-ON or OFF-AUTO Selector Switch L1 FUSE * REMOTE DEVICE OFF SS AUTO AUXILIARY CONTACT A2 ON COIL OFF A1 FUSE * L2 OFF-ON-AUTO HAND-OFF-AUTO Selector Switch L1 FUSE * REMOTE DEVICE OFF ON AUTO AUXILIARY CONTACT A2 ON COIL OFF A1 FUSE * L2 NEMA & General Purpose Control * -- IF USED 17 CONTROL PRODUCTS Siemens Industry, Inc. SPEEDFAX Product Catalog 17-171
- Page 1147 and 1148: Manual Control Heater Elements, Cla
- Page 1149 and 1150: Replacement Parts Starters and Cont
- Page 1151 and 1152: Replacement Parts Lighting Contacto
- Page 1153 and 1154: Replacement Parts Miscellaneous Sel
- Page 1155 and 1156: Manual Control Class SMF, MMS Dimen
- Page 1157 and 1158: Heavy Duty Motor Starters Solid Sta
- Page 1159 and 1160: Heavy Duty Contactors Class 40 Dime
- Page 1161 and 1162: Overload Relays & Current Transform
- Page 1163 and 1164: Lighting & Heating Contactors Open
- Page 1165 and 1166: GROUND 1/ L1 3/ L2 5/ L3 2/ T1 11 2
- Page 1167 and 1168: Lighting & Heating Contactors Mecha
- Page 1169 and 1170: Heavy Duty Motor Starters & Contact
- Page 1171 and 1172: Combination Heavy Duty Starters Enc
- Page 1173 and 1174: Reversing Heavy Duty Starters & Con
- Page 1175 and 1176: Combination Reversing Heavy Duty St
- Page 1177 and 1178: Combination Two Speed Heavy Duty St
- Page 1179 and 1180: Duplex Heavy Duty Controllers Class
- Page 1181 and 1182: Lighting Contactors Enclosed Contac
- Page 1183 and 1184: Manual Control Class 11 - 3RV, SMF,
- Page 1185 and 1186: Combination Heavy Duty Starters Cla
- Page 1187 and 1188: Combination Reversing Heavy Duty St
- Page 1189 and 1190: Two Speed Heavy Duty Starters Class
- Page 1191 and 1192: SEK SES SAW LMB SEK SES SAW LMB SEK
- Page 1193 and 1194: Reduced Voltage Starters & Pump Pan
- Page 1195 and 1196: Duplex Heavy Duty Controllers Class
- Page 1197: Standard & Irrigation Pump Panels C
- Page 1201 and 1202: Lighting and Heating Contactors Mec
- Page 1203 and 1204: 240V 230V 220V 480V 230V 460V 220V
- Page 1205 and 1206: Enclosed IEC Controls 3RE4 IEC Cont
- Page 1207 and 1208: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1209 and 1210: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1211 and 1212: Enclosed IEC Controls Selection Tab
- Page 1213 and 1214: Enclosed IEC Controls 3RE4 Factory
- Page 1215 and 1216: Enclosed IEC Controls 3RE4 Field Mo
- Page 1217 and 1218: Enclosed IEC Controls 3RE4 Outline
- Page 1219 and 1220: Enclosed IEC Controls 3RE4 Wiring D
- Page 1221 and 1222: Motor Starters, Soft Starters and L
- Page 1223 and 1224: For Operation in the Control Cabine
- Page 1225 and 1226: For Operation in the Control Cabine
- Page 1227 and 1228: For Operation in the Control Cabine
- Page 1229 and 1230: For Operation in the Control Cabine
- Page 1231 and 1232: Modules for RESET 1) Modules for re
- Page 1233 and 1234: For Operation in the Control Cabine
- Page 1235 and 1236: For Operation in the Control Cabine
- Page 1237 and 1238: For Operation in the Control Cabine
- Page 1239 and 1240: Planning and Configuration with SIR
- Page 1241 and 1242: Planning and Configuration with SIR
- Page 1243 and 1244: Planning and Configuration with SIR
- Page 1245 and 1246: For Operation in the Control Cabine
- Page 1247 and 1248: For Operation in the Control Cabine
Duplex Heavy Duty Controllers<br />
Class LC and LE Electrically Held Contactors<br />
Wiring Diagrams<br />
Optional Pilot Devices for Electrically Held Contactor<br />
OFF PB<br />
ON PB<br />
ON<br />
ON and OFF<br />
Push buttons<br />
L1<br />
FUSE *<br />
A2<br />
COIL<br />
A1<br />
FUSE<br />
*<br />
L2<br />
REMOTE OFF<br />
AUXILIARY<br />
CONTACT<br />
REMOTE<br />
ON<br />
AUXILIARY<br />
CONTACT<br />
OFF<br />
OFF-ON or<br />
OFF-AUTO<br />
Selector<br />
Switch<br />
L1<br />
FUSE<br />
*<br />
REMOTE<br />
DEVICE<br />
OFF<br />
SS<br />
AUTO<br />
AUXILIARY<br />
CONTACT<br />
A2<br />
ON<br />
COIL<br />
OFF<br />
A1<br />
FUSE<br />
*<br />
L2<br />
OFF-ON-AUTO<br />
HAND-OFF-AUTO<br />
Selector<br />
Switch<br />
L1<br />
FUSE<br />
*<br />
REMOTE<br />
DEVICE<br />
OFF<br />
ON<br />
AUTO<br />
AUXILIARY<br />
CONTACT<br />
A2<br />
ON<br />
COIL<br />
OFF<br />
A1<br />
FUSE<br />
*<br />
L2<br />
NEMA & General<br />
Purpose Control<br />
* -- IF USED<br />
17 CONTROL<br />
PRODUCTS<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog 17-171