Reversing Heavy Duty Starters<br />

Class 22<br />

Wiring Diagrams<br />

3-Phase Solid State Overload<br />

3-Phase Reversing Magnetic Starter<br />

Sizes 00–1 WIRING 3 ⁄4 DIAGRAM<br />

NEMA 00 - 1 3 4<br />

3-Phase Reversing Magnetic Starter<br />

Sizes 2–4<br />

WIRING DIAGRAM<br />

NEMA 2 - 4<br />

TO SUPPLY<br />

L1 L2 L3<br />

TO SUPPLY<br />

L1 L2 L3<br />

3<br />

2<br />

1<br />

5<br />

V W<br />

FOR<br />

7 6 V<br />

REV<br />

W<br />

1<br />

4<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

A<br />

B<br />

T1 T2 T3<br />

T2<br />

T1 T3<br />

MOTOR<br />

Solid State Overload<br />

3 PHASE REVERSING<br />

Sizes 5–6<br />

MAGNETIC STARTER<br />

TO SUPPLY<br />

L1 L2 L3<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

96 CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

V FOR W<br />

T1 T2 T3<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

MOTOR<br />

3<br />

2<br />

7<br />

A<br />

5<br />

4<br />

6<br />

V<br />

REV<br />

3 PHASE REVERSING<br />

MAGNETIC STARTER<br />

B<br />

W<br />

1<br />

1<br />

96<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

C H2<br />

SEC<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

NEMA & General<br />

Purpose Control<br />

"FWD"<br />

CONTRACTOR<br />

CONTACTOR<br />

MECHANICAL<br />

INTERLOCK<br />

"REV"<br />

CONTACTOR<br />

CURRENT<br />

TRANSFORMER<br />

(SEE TABLE)<br />

O.L.<br />

RELAY<br />

17<br />

CONTROL<br />

PRODUCTS<br />

MOTOR<br />

REMOVE WIRE "C" IF THE CONTACTOR<br />

COIL IS TO OPERATE ON A VOLTAGE<br />

OTHER THAN LINE VOLTAGE OR ON A<br />

SEPARATE CONTROL SOURCE.<br />

3-Phase Reversing Magnetic Starter<br />

with DC Coil, WIRING Sizes DIAGRAM 00–1 3 ⁄4<br />

TO SUPPLY<br />

L1 L2 L3<br />

NEMA 00 - 1 3 4<br />

3-Phase Reversing Magnetic Starter<br />

with DC Coil, Sizes 2–4<br />

TO SUPPLY<br />

L1 L2 L3<br />

WIRING DIAGRAM<br />

NEMA 2 - 4<br />

1<br />

3<br />

5<br />

7<br />

3<br />

V<br />

FOR<br />

W<br />

5<br />

V<br />

REV<br />

W<br />

6<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

V<br />

FOR<br />

W<br />

V<br />

REV<br />

W<br />

17-158<br />

2 T1<br />

T2 T3 4<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

T2<br />

MOTOR<br />

T1 T3<br />

LATE BREAK<br />

3 PHASE REVERSING<br />

MAGNETIC STARTER W/DC COIL<br />

96 CONTROL<br />

TRANSFORMER<br />

(OPTIONAL)<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog<br />

B<br />

1<br />

C<br />

H2<br />

H3<br />

H1<br />

SEC<br />

X2<br />

2<br />

7<br />

ESP200<br />

95 96 97 98<br />

A3+A4-<br />

T1 T2 T3<br />

T1<br />

L.B.<br />

T2<br />

1<br />

T3<br />

MOTOR<br />

CONTROL FUSES<br />

(OPTIONAL)<br />

B<br />

L.B.<br />

96<br />

SEC FUSE<br />

XF<br />

H4<br />

X1<br />

CONTROL<br />

C H2<br />

TRANSFORMER<br />

SEC (OPTIONAL)<br />

H3<br />

X2<br />

H1<br />

MAY BE<br />

GROUNDED BY<br />

CUSTOMER<br />

3 PHASE REVERSING<br />

MAGNETIC STARTER W/DC COIL<br />

4<br />

6