12.01.2021 Views

Speedfax 2017

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Lighting Contactors<br />

Enclosed Contactors, Class LC and LE<br />

Revised on 03/31/20<br />

Dimensions<br />

Figure 1 Figure 2 Figure 3<br />

Class LC and LE Non-combo<br />

Enclosure<br />

Type Contactor Rating Fig.<br />

1<br />

without<br />

CPT<br />

1<br />

with<br />

CPT<br />

3/3R/4/12<br />

without<br />

CPT<br />

4/4X<br />

without<br />

CPT<br />

3/3R/4/12<br />

with<br />

CPT<br />

4/4X<br />

with<br />

CPT<br />

Outline Dimensions Mounting a Conduit Size Reference<br />

A B C D E K1 K2 K3 K4 K5 Drawing<br />

LE 20/30A 3-4P 1 10.97 6.41 5.03 8.22 4.62 0.5 0.50 – 0.75 0.75 – 1 — —<br />

LC 30A 2-12P, LE 60A 3P 1 13.53 7.97 6.38 10.25 6 0.50 – 0.75 0.75 – 1 1 – 1.25 — —<br />

LE 30/60A 6-12P, LE 100A 3P 1 19.12 11.38 7.69 15.62 8.25 0.50 – 0.75 1 – 1.25 1.5 – 2 — —<br />

LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 0.50 – 0.75 1.25 – 1.5 1.25 – 1.5 — —<br />

LC 30A 2-12P, LE 20A 3-4P,<br />

LE 30A 3-9P, LE 60A 3-9P, 1 19.12 11.38 7.69 15.62 8.25 0.50 – 0.75 1 – 1.25 1.5 – 2 — —<br />

LE 100A 3P<br />

LE 30/60A 12P 1 24.88 13.38 8.12 21.75 9 0.50 – 0.75 1.25 – 1.5 2 – 2.5 — —<br />

LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 — 1.25 – 1.5 1.25 – 1.5 — —<br />

LE 20A 3-4P, LE 30/60A 3-9P,<br />

LC 30A 2-12P<br />

2 16 13.25 6.12 15.25 11 — — — — —<br />

LE 30/60A 12P 2 26 13.12 7.56 25.25 10 — — — — —<br />

LE 100A 3P 2 26 13.12 7.56 25.25 10 — — — — —<br />

LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 — — — — —<br />

LE 20A 3-4P, LE 30/60A<br />

3-9P,LC 30A 2-12P<br />

2 16 14 6.02 16.75 12 — — — — —<br />

LE 30/60A, 12P 2 24 16 8.76 22.5 14.5 — — — — —<br />

LE 100A 3P 2 24 16 8.76 22.5 14.5 — — — — —<br />

LE 200-400A,3P 2 24 20 10 22.5 18.5 — — — — —<br />

LE 20A 3-4P, LE 30/60A<br />

3-9P,LC 30A 2-12P<br />

2 16 13.25 6.12 15.25 11 — — — — —<br />

LE 30/60A, 12P 2 26 13.12 7.56 25.25 10 — — — — —<br />

LE 100A 3P 2 26 13.12 7.56 25.25 10 — — — — —<br />

LE 200-400A,3P 2 26 17.62 12.5 25.19 15.5 — — — — —<br />

LE 20A 3-4P, LE 30/60A<br />

3-9P,LC 30A 2-12P<br />

2 16 14 6.02 16.75 12 — — — — —<br />

LE 30/60A, 12P 2 24 16 8.76 22.5 14.5 — — — — —<br />

LE 100A 3P 2 24 16 8.76 22.5 14.5 — — — — —<br />

LE 200-400A,3P 2 24 20 10 22.5 18.5 — — — — —<br />

NEMA & General<br />

Purpose Control<br />

17 CONTROL<br />

PRODUCTS<br />

Class LE Combo<br />

Enclosure<br />

Type<br />

1, 12/3R &<br />

4/4X with &<br />

without CPT<br />

Type<br />

Fusible and<br />

Non-fusible Disconnect<br />

Contactor<br />

Outline Dimensions<br />

Rating Fig. A B C<br />

20–60A 3 24 11 8<br />

100A 3 24 20 8<br />

200A 3 46 20 10<br />

300A 3 76 22 13<br />

Circuit Breaker 20–100A 3 24 11 8<br />

Reference<br />

Drawing<br />

Note: Dimensions are in inches. a Mounting screw G size is 0.25".<br />

Siemens Industry, Inc. SPEEDFAX Product Catalog 17-153

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!