Speedfax 2017
H I J Pump Control Panels Class 87, 88 Revised on 10/31/19 Dimensions Outline Drawings F Figure 1 F B E Figure 2 5.000 C Figure 3 C F B Opening for Conduit Hub Size "P" C A D G B H C K Mounting Hole for 1/4" screw L D A Handle (Optional) F E B Figure 4 A D G A B H C K L Handle (Optional) NEMA & General Purpose Control L M L N Mounting Holes For 5/16" Hardware F E J (4) .687 Dia Holes D G A K J (4) .687 Dia Holes 17 CONTROL PRODUCTS Open air contacts Size Fig. Outline Dimensions Mounting Dimensions Conduit Knockout Hub Reference Drawing F A B C D E F G H I J K L M E NG P 1–2 1/2 1 28.50 20.00 8.06 24.00 — 10.00 27.00 5.50 8.50 11.50 — 0.5 – 0.75 1.25 – 1 0.75 – 1 1.50 3 – 4 1 40.50 24.00 8.09 36.00 — 12.00 39.00 8.44 11.94 15.44 — 1.97 – 2.47 0.88 – 1.13 — 2.50 5 2 72.16 20.00 10.00 71.00 16.00 2.13 70.91 — — — — — — — — 6 2 60.00 38.00 16.00 61.60 36.50 0.75 — — — — — — — — Vacuum contacts Outline Dimensions Mounting Dimensions Conduit Knockout Hub Reference Size Fig. A B C D E F G H I J K L M N P Drawing 4 2 55.97 24.38 9.69 54.81 20.25 2.13 54.72 26.19 — — 27.44 — — — — 5 2 72.16 20.00 10.00 71.00 16.00 2.13 70.91 — — — — — — — — 6 2 60.00 38.00 16.00 61.60 36.50 0.75 — — — — — — — — D Reduced voltage Size AutoTransformer Part Winding & Wye Delta Outline Dimensions Disc. & MCP Type Disc. Type MCP Type Fig. A B C D E 2-2 1/2 1–2 1–2 1/2 3 42.00 32.00 12.00 43.60 30.50 3-3 1/2 2 1/2–3 1/2 3–3 1/2 3 48.00 38.00 12.00 49.60 36.50 4 4 4 3 60.00 38.00 16.00 61.60 36.50 5, 6 5, 6 5, 6 4 90.00 30.00 20.00 16.00 24.44 Reference Drawing Note: Dimensions are in inches. All enclosures are Type 3R 17-152 Siemens Industry, Inc. SPEEDFAX Product Catalog
Lighting Contactors Enclosed Contactors, Class LC and LE Revised on 03/31/20 Dimensions Figure 1 Figure 2 Figure 3 Class LC and LE Non-combo Enclosure Type Contactor Rating Fig. 1 without CPT 1 with CPT 3/3R/4/12 without CPT 4/4X without CPT 3/3R/4/12 with CPT 4/4X with CPT Outline Dimensions Mounting a Conduit Size Reference A B C D E K1 K2 K3 K4 K5 Drawing LE 20/30A 3-4P 1 10.97 6.41 5.03 8.22 4.62 0.5 0.50 – 0.75 0.75 – 1 — — LC 30A 2-12P, LE 60A 3P 1 13.53 7.97 6.38 10.25 6 0.50 – 0.75 0.75 – 1 1 – 1.25 — — LE 30/60A 6-12P, LE 100A 3P 1 19.12 11.38 7.69 15.62 8.25 0.50 – 0.75 1 – 1.25 1.5 – 2 — — LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 0.50 – 0.75 1.25 – 1.5 1.25 – 1.5 — — LC 30A 2-12P, LE 20A 3-4P, LE 30A 3-9P, LE 60A 3-9P, 1 19.12 11.38 7.69 15.62 8.25 0.50 – 0.75 1 – 1.25 1.5 – 2 — — LE 100A 3P LE 30/60A 12P 1 24.88 13.38 8.12 21.75 9 0.50 – 0.75 1.25 – 1.5 2 – 2.5 — — LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 — 1.25 – 1.5 1.25 – 1.5 — — LE 20A 3-4P, LE 30/60A 3-9P, LC 30A 2-12P 2 16 13.25 6.12 15.25 11 — — — — — LE 30/60A 12P 2 26 13.12 7.56 25.25 10 — — — — — LE 100A 3P 2 26 13.12 7.56 25.25 10 — — — — — LE 200-400A 3P 2 26 17.62 12.5 25.19 15.5 — — — — — LE 20A 3-4P, LE 30/60A 3-9P,LC 30A 2-12P 2 16 14 6.02 16.75 12 — — — — — LE 30/60A, 12P 2 24 16 8.76 22.5 14.5 — — — — — LE 100A 3P 2 24 16 8.76 22.5 14.5 — — — — — LE 200-400A,3P 2 24 20 10 22.5 18.5 — — — — — LE 20A 3-4P, LE 30/60A 3-9P,LC 30A 2-12P 2 16 13.25 6.12 15.25 11 — — — — — LE 30/60A, 12P 2 26 13.12 7.56 25.25 10 — — — — — LE 100A 3P 2 26 13.12 7.56 25.25 10 — — — — — LE 200-400A,3P 2 26 17.62 12.5 25.19 15.5 — — — — — LE 20A 3-4P, LE 30/60A 3-9P,LC 30A 2-12P 2 16 14 6.02 16.75 12 — — — — — LE 30/60A, 12P 2 24 16 8.76 22.5 14.5 — — — — — LE 100A 3P 2 24 16 8.76 22.5 14.5 — — — — — LE 200-400A,3P 2 24 20 10 22.5 18.5 — — — — — NEMA & General Purpose Control 17 CONTROL PRODUCTS Class LE Combo Enclosure Type 1, 12/3R & 4/4X with & without CPT Type Fusible and Non-fusible Disconnect Contactor Outline Dimensions Rating Fig. A B C 20–60A 3 24 11 8 100A 3 24 20 8 200A 3 46 20 10 300A 3 76 22 13 Circuit Breaker 20–100A 3 24 11 8 Reference Drawing Note: Dimensions are in inches. a Mounting screw G size is 0.25". Siemens Industry, Inc. SPEEDFAX Product Catalog 17-153
- Page 1129 and 1130: Field Modification Kits Class 11 -
- Page 1131 and 1132: Field Modification Kits Pilot Light
- Page 1133 and 1134: Field Modification Kits NEMA, Reduc
- Page 1135 and 1136: Field Modification Kits NEMA Access
- Page 1137 and 1138: Field Modification Kits NEMA, Overl
- Page 1139 and 1140: Heavy Duty Control Non-Combination
- Page 1141 and 1142: Combination Starter Enclosure Kits
- Page 1143 and 1144: Factory Modifications Revised on 03
- Page 1145 and 1146: Factory Modifications Revised on 03
- Page 1147 and 1148: Manual Control Heater Elements, Cla
- Page 1149 and 1150: Replacement Parts Starters and Cont
- Page 1151 and 1152: Replacement Parts Lighting Contacto
- Page 1153 and 1154: Replacement Parts Miscellaneous Sel
- Page 1155 and 1156: Manual Control Class SMF, MMS Dimen
- Page 1157 and 1158: Heavy Duty Motor Starters Solid Sta
- Page 1159 and 1160: Heavy Duty Contactors Class 40 Dime
- Page 1161 and 1162: Overload Relays & Current Transform
- Page 1163 and 1164: Lighting & Heating Contactors Open
- Page 1165 and 1166: GROUND 1/ L1 3/ L2 5/ L3 2/ T1 11 2
- Page 1167 and 1168: Lighting & Heating Contactors Mecha
- Page 1169 and 1170: Heavy Duty Motor Starters & Contact
- Page 1171 and 1172: Combination Heavy Duty Starters Enc
- Page 1173 and 1174: Reversing Heavy Duty Starters & Con
- Page 1175 and 1176: Combination Reversing Heavy Duty St
- Page 1177 and 1178: Combination Two Speed Heavy Duty St
- Page 1179: Duplex Heavy Duty Controllers Class
- Page 1183 and 1184: Manual Control Class 11 - 3RV, SMF,
- Page 1185 and 1186: Combination Heavy Duty Starters Cla
- Page 1187 and 1188: Combination Reversing Heavy Duty St
- Page 1189 and 1190: Two Speed Heavy Duty Starters Class
- Page 1191 and 1192: SEK SES SAW LMB SEK SES SAW LMB SEK
- Page 1193 and 1194: Reduced Voltage Starters & Pump Pan
- Page 1195 and 1196: Duplex Heavy Duty Controllers Class
- Page 1197 and 1198: Standard & Irrigation Pump Panels C
- Page 1199 and 1200: Duplex Heavy Duty Controllers Class
- Page 1201 and 1202: Lighting and Heating Contactors Mec
- Page 1203 and 1204: 240V 230V 220V 480V 230V 460V 220V
- Page 1205 and 1206: Enclosed IEC Controls 3RE4 IEC Cont
- Page 1207 and 1208: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1209 and 1210: Enclosed IEC Controls 3RE4 Non-Reve
- Page 1211 and 1212: Enclosed IEC Controls Selection Tab
- Page 1213 and 1214: Enclosed IEC Controls 3RE4 Factory
- Page 1215 and 1216: Enclosed IEC Controls 3RE4 Field Mo
- Page 1217 and 1218: Enclosed IEC Controls 3RE4 Outline
- Page 1219 and 1220: Enclosed IEC Controls 3RE4 Wiring D
- Page 1221 and 1222: Motor Starters, Soft Starters and L
- Page 1223 and 1224: For Operation in the Control Cabine
- Page 1225 and 1226: For Operation in the Control Cabine
- Page 1227 and 1228: For Operation in the Control Cabine
- Page 1229 and 1230: For Operation in the Control Cabine
H<br />
I<br />
J<br />
Pump Control Panels<br />
Class 87, 88<br />
Revised on 10/31/19<br />
Dimensions<br />
Outline Drawings<br />
F<br />
Figure 1<br />
F<br />
B<br />
E<br />
Figure 2<br />
5.000<br />
C<br />
Figure 3<br />
C<br />
F<br />
B<br />
Opening for<br />
Conduit Hub<br />
Size "P"<br />
C<br />
A D G<br />
B<br />
H<br />
C<br />
K<br />
Mounting Hole<br />
for 1/4" screw<br />
L<br />
D<br />
A<br />
Handle<br />
(Optional)<br />
F<br />
E<br />
B<br />
Figure 4<br />
A<br />
D G<br />
A<br />
B<br />
H<br />
C<br />
K<br />
L<br />
Handle<br />
(Optional)<br />
NEMA & General<br />
Purpose Control<br />
L M L N<br />
Mounting Holes<br />
For 5/16" Hardware<br />
F<br />
E<br />
J<br />
(4) .687 Dia Holes<br />
D<br />
G<br />
A<br />
K<br />
J<br />
(4) .687 Dia Holes<br />
17<br />
CONTROL<br />
PRODUCTS<br />
Open air contacts<br />
Size<br />
Fig.<br />
Outline Dimensions Mounting Dimensions Conduit Knockout Hub Reference<br />
Drawing<br />
F<br />
A B C D E F G H I J K L M<br />
E<br />
NG<br />
P<br />
1–2 1/2 1 28.50 20.00 8.06 24.00 — 10.00 27.00 5.50 8.50 11.50 — 0.5 – 0.75 1.25 – 1 0.75 – 1 1.50<br />
3 – 4 1 40.50 24.00 8.09 36.00 — 12.00 39.00 8.44 11.94 15.44 — 1.97 – 2.47 0.88 – 1.13 — 2.50<br />
5 2 72.16 20.00 10.00 71.00 16.00 2.13 70.91 — — — — — — — —<br />
6 2 60.00 38.00 16.00 61.60 36.50 0.75 — — — — — — — —<br />
Vacuum contacts<br />
Outline Dimensions Mounting Dimensions Conduit Knockout Hub Reference<br />
Size Fig. A B C D E F G H I J K L M N P Drawing<br />
4 2 55.97 24.38 9.69 54.81 20.25 2.13 54.72 26.19 — — 27.44 — — — —<br />
5 2 72.16 20.00 10.00 71.00 16.00 2.13 70.91 — — — — — — — —<br />
6 2 60.00 38.00 16.00 61.60 36.50 0.75 — — — — — — — —<br />
D<br />
Reduced voltage<br />
Size<br />
AutoTransformer Part Winding & Wye Delta<br />
Outline Dimensions<br />
Disc. & MCP Type Disc. Type MCP Type Fig. A B C D E<br />
2-2 1/2 1–2 1–2 1/2 3 42.00 32.00 12.00 43.60 30.50<br />
3-3 1/2 2 1/2–3 1/2 3–3 1/2 3 48.00 38.00 12.00 49.60 36.50<br />
4 4 4 3 60.00 38.00 16.00 61.60 36.50<br />
5, 6 5, 6 5, 6 4 90.00 30.00 20.00 16.00 24.44<br />
Reference<br />
Drawing<br />
Note: Dimensions are in inches.<br />
All enclosures are Type 3R<br />
17-152<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog