Speedfax 2017
Combination Starter Enclosure Kits Revised on 03/31/20 Features and Benefits Features b 100kA short circuit rating when protected with class R fuses to 600V or MCP to 480V and when installing listed components from the instruction guide b Enclosure types available, NEMA 1, 12, 3R and painted NEMA 4. b Pre-Drilled mounting panels b Heavy duty quarter turns b Industrial type disconnect handle Disconnect Type Enclosure Kit b Used to assemble both non-fusible and fusible combination starters b Accommodates Class 14 full voltage non-reversing (FVNR) NEMA starters 00 – 4 including Siemens exclusive half sizes b Handle mechanism, power wire, mounting panel, reset assembly, and instruction guide included. Hardware for panel mounted devices and disconnect switch are not included NEMA & General Purpose Control 17 CONTROL PRODUCTS MCP Type Enclosure Kit b Used to assemble combination starters with circuit breakers b Accommodates Class 14 full voltage non-reversing (FVNR) NEMA starters 00 – 4 including Siemens exclusive half sizes b Handle mechanism, power wire, mounting panel, reset assembly and instruction guide included. Circuit breaker not included however, mounting hardware for the circuit breaker is. How to Select the Required Kits to Assemble a Combination Starter 1. From the catalog, select a class 14 open type starter. 2. Based on the starter size, select the enclosure kit from table 1a for fusible or non-fusible combination starters or select from table 1b for combination starters with an MCP. 3. For a non-fusible combination starter, select the disconnect switch kit from table 2a. For a fusible combination starter, select the appropriate disconnect switch, fuse clip kit, and class R rejection kit from table 2b (for H fusing, class R rejection kit not required). For combination starters with MCP, select the appropriate circuit breaker kit from table 3. Nomenclature for Combination Enclosure Kits 49 E C 17 B B 24 11 08 R Class 49 — Field Kit Type E — Enclosure Kit Model C — Model C Product Class 17 — Disconnect Type 18 — Circuit Breaker Type Enclosure Type B — NEMA 1 N — NEMA 3R/4/12 Height (In Inches) Width (In Inches) Depth (In Inches) Reset Installation R — Reset Installed Disc / CB Amp Rating B — 30/60 amp disconnect C — 100 amp disconnect D— 125 amp breaker frame E — 150 amp breaker frame F — 200 amp disconnect 17-112 Siemens Industry, Inc. SPEEDFAX Product Catalog
Combination Starter Enclosure Kits Revised on 10/15/20 Selection Table 1a - FVNR Combination Starter Kits for use with Disconnect Devices Starter Size Disc. Amp Rating NEMA 1 General Purpose Catalog Number NEMA 3R/4/12 Watertight, Dust-tight, Weatherproof Catalog Number 0 - 2 60 49EC17BB241108R 49EC17BN241108R 2 ½ - 3 100 49EC17CB242008R 49EC17CN242008R Table 1b. – FVNR Combination Starter Kits for use with MCP Devices Starter Size Max MCP Amps NEMA 1 General Purpose Catalog Number NEMA 3R/4/12 Watertight, Dust-tight, Weatherproof Catalog Number 0 - 2 50 49EC18DB241108R 49EC18DN241108R 2 ½ - 3 125 49EC18DB242008R 49EC18DN242008R Table 2a – Non-Fusible Disconnect Kits Disconnect Switch Switch Rating 30A 60A 100A 200A Catalog Number HNB612 HNB623 HNB623 HNB64 Table 2b – Fusible Disconnect Kits Fuse Clip Ratings Table 3 – Circuit Breaker Kits MCP Type Used with Solid State Overload Relay Starter Size Class Overload Amp Range Rejection Clips Disconnect Switch Load Base for Fuse for Class R Fusing Catalog Number Catalog Number Catalog Number 30A-250V H HFB21 HBB21 HR21 30A-600V H HFB612 HBB612 HR612 60A-250V H HFB22 HBB22 HR612 60A-600V H HFB62 HBB62 HR62 100A-250V H HFB63 HBB63 HR63 100A-600V H HFB63 HBB63 HR63 200A-250V H HFB64 HBB64 HR64 200A-600V H HFB64 HBB64 HR64 Motor Circuit Interrupter Amps Circuit Breaker Kit 0.75-3.4 3 ED63A003 0 3-12 10 ED63A010 5.5-22 25 ED63A025 0.75-3.4 3 ED63A003 1 3-12 10 ED63A010 5.5-22 25 ED63A025 10-40 30 ED63A030 1 3 ⁄4 10-40 40 ED63A040 2 13-52 50 ED63A050 2 1 ⁄2 25-100 100 ED63A100 3 25-100 100 ED63A100 3 1 ⁄2 50-200 125 ED63A125 4 50-200 150 FXD63A150L NEMA & General Purpose Control 17 CONTROL PRODUCTS Product Category: NEMA Siemens Industry, Inc. SPEEDFAX Product Catalog 17-113
- Page 1089 and 1090: Heavy Duty Control Catalog Numberin
- Page 1091 and 1092: Overload Relays Solid State ESP200,
- Page 1093 and 1094: Overload Relays Special Use Solid S
- Page 1095 and 1096: Duplex Heavy Duty Controllers Non-C
- Page 1097 and 1098: Duplex Heavy Duty Controllers Combi
- Page 1099 and 1100: Pump Control Panels Slim Line NEMA
- Page 1101 and 1102: Pump Control Panels Slim Line NEMA
- Page 1103 and 1104: Pump Control Panels Class 87, 88 Re
- Page 1105 and 1106: Vacuum Break and Oil Well Pump Cont
- Page 1107 and 1108: Reduced Voltage Pump Panels Wye Del
- Page 1109 and 1110: Lighting and Heating Control Electr
- Page 1111 and 1112: Lighting and Heating Control Electr
- Page 1113 and 1114: Lighting and Heating Control Electr
- Page 1115 and 1116: Lighting and Heating Control Electr
- Page 1117 and 1118: Lighting and Heating Control Electr
- Page 1119 and 1120: Lighting and Heating Control Electr
- Page 1121 and 1122: Lighting Control Mechanically and M
- Page 1123 and 1124: Industrial Control Power Transforme
- Page 1125 and 1126: Industrial Control Power Transforme
- Page 1127 and 1128: Industrial Control Power Transforme
- Page 1129 and 1130: Field Modification Kits Class 11 -
- Page 1131 and 1132: Field Modification Kits Pilot Light
- Page 1133 and 1134: Field Modification Kits NEMA, Reduc
- Page 1135 and 1136: Field Modification Kits NEMA Access
- Page 1137 and 1138: Field Modification Kits NEMA, Overl
- Page 1139: Heavy Duty Control Non-Combination
- Page 1143 and 1144: Factory Modifications Revised on 03
- Page 1145 and 1146: Factory Modifications Revised on 03
- Page 1147 and 1148: Manual Control Heater Elements, Cla
- Page 1149 and 1150: Replacement Parts Starters and Cont
- Page 1151 and 1152: Replacement Parts Lighting Contacto
- Page 1153 and 1154: Replacement Parts Miscellaneous Sel
- Page 1155 and 1156: Manual Control Class SMF, MMS Dimen
- Page 1157 and 1158: Heavy Duty Motor Starters Solid Sta
- Page 1159 and 1160: Heavy Duty Contactors Class 40 Dime
- Page 1161 and 1162: Overload Relays & Current Transform
- Page 1163 and 1164: Lighting & Heating Contactors Open
- Page 1165 and 1166: GROUND 1/ L1 3/ L2 5/ L3 2/ T1 11 2
- Page 1167 and 1168: Lighting & Heating Contactors Mecha
- Page 1169 and 1170: Heavy Duty Motor Starters & Contact
- Page 1171 and 1172: Combination Heavy Duty Starters Enc
- Page 1173 and 1174: Reversing Heavy Duty Starters & Con
- Page 1175 and 1176: Combination Reversing Heavy Duty St
- Page 1177 and 1178: Combination Two Speed Heavy Duty St
- Page 1179 and 1180: Duplex Heavy Duty Controllers Class
- Page 1181 and 1182: Lighting Contactors Enclosed Contac
- Page 1183 and 1184: Manual Control Class 11 - 3RV, SMF,
- Page 1185 and 1186: Combination Heavy Duty Starters Cla
- Page 1187 and 1188: Combination Reversing Heavy Duty St
- Page 1189 and 1190: Two Speed Heavy Duty Starters Class
Combination Starter Enclosure Kits<br />
Revised on 03/31/20<br />
Features and Benefits<br />
Features<br />
b 100kA short circuit rating when protected with class R fuses<br />
to 600V or MCP to 480V and when installing listed components<br />
from the instruction guide<br />
b Enclosure types available, NEMA 1, 12, 3R and painted NEMA 4.<br />
b Pre-Drilled mounting panels<br />
b Heavy duty quarter turns<br />
b Industrial type disconnect handle<br />
Disconnect Type Enclosure Kit<br />
b Used to assemble both non-fusible and fusible combination starters<br />
b Accommodates Class 14 full voltage non-reversing (FVNR) NEMA<br />
starters 00 – 4 including Siemens exclusive half sizes<br />
b Handle mechanism, power wire, mounting panel, reset assembly,<br />
and instruction guide included. Hardware for panel mounted<br />
devices and disconnect switch are not included<br />
NEMA & General<br />
Purpose Control<br />
17<br />
CONTROL<br />
PRODUCTS<br />
MCP Type Enclosure Kit<br />
b Used to assemble combination starters with circuit breakers<br />
b Accommodates Class 14 full voltage non-reversing (FVNR) NEMA<br />
starters 00 – 4 including Siemens exclusive half sizes<br />
b Handle mechanism, power wire, mounting panel, reset assembly<br />
and instruction guide included. Circuit breaker not included however,<br />
mounting hardware for the circuit breaker is.<br />
How to Select the Required Kits to Assemble a Combination Starter<br />
1. From the catalog, select a class 14 open type starter.<br />
2. Based on the starter size, select the enclosure kit from table 1a for<br />
fusible or non-fusible combination starters or select from table 1b<br />
for combination starters with an MCP.<br />
3. For a non-fusible combination starter, select the disconnect switch kit from table 2a.<br />
For a fusible combination starter, select the appropriate disconnect switch, fuse clip<br />
kit, and class R rejection kit from table 2b (for H fusing, class R rejection kit not required).<br />
For combination starters with MCP, select the appropriate circuit breaker kit from table 3.<br />
Nomenclature for Combination Enclosure Kits<br />
49 E C 17 B B 24 11 08 R<br />
Class<br />
49 — Field Kit<br />
Type<br />
E — Enclosure Kit<br />
Model<br />
C — Model C<br />
Product Class<br />
17 — Disconnect Type<br />
18 — Circuit Breaker Type<br />
Enclosure Type<br />
B — NEMA 1<br />
N — NEMA 3R/4/12<br />
Height<br />
(In Inches)<br />
Width<br />
(In Inches)<br />
Depth<br />
(In Inches)<br />
Reset Installation<br />
R — Reset Installed<br />
Disc / CB Amp Rating<br />
B — 30/60 amp disconnect<br />
C — 100 amp disconnect<br />
D— 125 amp breaker frame<br />
E — 150 amp breaker frame<br />
F — 200 amp disconnect<br />
17-112<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog