Speedfax 2017
Field Modification Kits ESP200 Accessories Revised on 01/26/18 Selection Accessories Description Catalog Number List Price $ ESP200 Tamper Resistance Cover 49ASTC1 3UB89848 ESP100/200 Mounting Plate Frame Size Controller Size A or A1 00 - 1 3/4 49ASMP1 B 2 -2 1/2 49ASMP2 B 3-4 49ASMP3 Mounting Kit 49ASMS1 Universal Reset Operator 8" for class 36, 37 and 87 in NEMA 1, 12 and 3/3R 49MARB NEMA & General Purpose Control Overload Relay Reset Operator for Class 14, 22, 30 and 83 non-combination starters in NEMA type 1, 12 and 4/4X enclosures Overload Relay Reset Operator for Class 17, 18, 25, 26, 32 and 84 combination starters in NEMA type 1 enclosures 49MBRS 49MBRS1 17 CONTROL PRODUCTS Overload Relay Reset Operator for Class 17, 18, 25, 26, 32 and 84 combination starters in NEMA type 12 and 4/4X enclosures Overload Relay Reset Operator with red button for any Class in NEMA type 1, 3R, 4/4X and 12 enclosures with a 30mm hole 49MBRS2 49MARSR ESP200 Reset Extender 49ASRE Protective Boot Offers protection from ice and foreign substances from interfering with button operation. For use with 49MARSR reset. 52AABA Current Transformer 300:5 use with 3UB81234JW2 97CT005 Current Transformer 400:5 use with 3UB81234KW2 97CT006 Current Transformer 600:5 use with 3UB81234LW2 97CT008 Current Transformer 750:5 use with 3UB81234MW2 97CT009 Current Transformer 1200:5 use with 3UB81234NW2 97CT012 17-106 Siemens Industry, Inc. SPEEDFAX Product Catalog Product Category: NEMA
Field Modification Kits NEMA Accessories Selection Miscellaneous Kits Encl. Controller Catalog List Description Class Type Size Number Price $ Mechanical Interlock 00–1 49CCF22H for Horizontally Mounted Contactors Includes wire 14, 40 Open 1 3 ⁄4 49EEF22H 2, 2 1 ⁄2 49GGF22H 3, 3 1 ⁄2 49HHP22H 4 49JJG22H Interlock Only 5, 6 3RA1954-2A 5 3RA1963-2A Wire Kit Only 14, 40 Open 6 3RA1973-2A 5 3RA1962-2A Base Plate Only 6 3RA1972-2A 7 49VM750H Mechanical Interlock 14, 40 Open 8 49VM1650H 00–1 49CCF22HP 1 3 ⁄4 49EEF22HP Includes wire & 14, 40 Open 2, 2 1 ⁄2 mounting plate 49GGF22HP 3, 3 1 ⁄2 49HHP22HP 4 49JJG22HP Includes Left Right mounting plate 14, 40 Open 2, 2 1 ⁄2 3, 3 1 ⁄2 49L107944 (Different Frame Sizes) 3, 3 1 ⁄2 2, 2 1 ⁄2 49L107945 Surge Suppressor for 120V AC Surge coil. Limits transient voltage All but Suppressor produced by the coil to 220% Class LC, LE, CLM maximum peak line volts. All 00–4 a 49D26344 Auxiliary NO 36A at 600V AC Max All but All 49SAF0 00–13⁄4 Power Pole NC 25A at 600V AC Max Class LC, LE, CLM 49SAFC Top or Bottom, 2-Pole CLM4097331 Main Contacts Top, 3-Pole CLM4097332 CLM All 20 Amps Lighting Contactors Top or Bottom, 4-Pole CLM4097333 Top or Bottom, 6-Pole CLM4097334 Load Side Includes 3 power lugs Power Take for making extra All but All 00–1 3 ⁄4 49SAE Off Kit connections to the load Class LC, LE, CLM side of the contactor Lug Kit for Contactors For AL/CU Wire 14, 40 All 2-2 1 ⁄2 49SAAF c 3-3 1 ⁄2 49SAAH c Item Wire Range 4 Line 4 Load 75D35994002 c 49SAAF 2-14 49SAAH 2/0-14 For AL/CU Wire 14, 40 All 5, 6 3RT1966-4G b 75D35994001 250MCM-6 7 49ZATK750-3 Use CU Only 14, 40 All 8 49ZATK1650-6 b Three Conductor Ground Lug Kit Meets UL 508 and CSA 2-14 AWG AL/CU Wire All All All 75D28182001 Standard 22.2 No 14-1973 Lightning Arrestor All All All 49D45584002 NEMA & General Purpose Control 17 CONTROL PRODUCTS Backspin Timer On delay timer that reduces risk of starting into a 87, 88 All All 3RP2025-1AQ30 3RP2025-1AP30 backspin Covers the hole that is Hole Plug typically used for the 87 All 1-4 49D41149006 conduit hub Hole Plug Covers the hole in the enclosure door/cover 40, 43, LC, LE, normally filled by overload reset 49MBRS. CLM & CM Hole plug is used for enclosed contactors. 1 All 49MZPB2 Illustration Description Contactor Wire Size Catalog Number List Price $ Lug Kit NEMA size 4 (Vacuum) 1 Kit = 1 Terminal block. 1 kit NEMA size 5 2/0 to 600 MCM, max. one 500MCM necessary for each line and load. NEMA size 6 & one 600MCM 3RT1966-4G 3RT1966-4G a Surge Suppression for NEMA sizes 5 – 8 are supplied internal with the coil. For size 4 panel mount. b Only 3 lugs are suplied for line or load. If lugs for line and load are required order 2 kits. c Lug Kit for contactors include 3 lugs for line or load. 75D35994001 for line side. 75D35994002 for load side. Product Category: NEMA Siemens Industry, Inc. SPEEDFAX Product Catalog 17-107
- Page 1083 and 1084: Definite Purpose Control Class 42 &
- Page 1085 and 1086: Definite Purpose Control Class 42 &
- Page 1087 and 1088: Definite Purpose Control C Class 42
- Page 1089 and 1090: Heavy Duty Control Catalog Numberin
- Page 1091 and 1092: Overload Relays Solid State ESP200,
- Page 1093 and 1094: Overload Relays Special Use Solid S
- Page 1095 and 1096: Duplex Heavy Duty Controllers Non-C
- Page 1097 and 1098: Duplex Heavy Duty Controllers Combi
- Page 1099 and 1100: Pump Control Panels Slim Line NEMA
- Page 1101 and 1102: Pump Control Panels Slim Line NEMA
- Page 1103 and 1104: Pump Control Panels Class 87, 88 Re
- Page 1105 and 1106: Vacuum Break and Oil Well Pump Cont
- Page 1107 and 1108: Reduced Voltage Pump Panels Wye Del
- Page 1109 and 1110: Lighting and Heating Control Electr
- Page 1111 and 1112: Lighting and Heating Control Electr
- Page 1113 and 1114: Lighting and Heating Control Electr
- Page 1115 and 1116: Lighting and Heating Control Electr
- Page 1117 and 1118: Lighting and Heating Control Electr
- Page 1119 and 1120: Lighting and Heating Control Electr
- Page 1121 and 1122: Lighting Control Mechanically and M
- Page 1123 and 1124: Industrial Control Power Transforme
- Page 1125 and 1126: Industrial Control Power Transforme
- Page 1127 and 1128: Industrial Control Power Transforme
- Page 1129 and 1130: Field Modification Kits Class 11 -
- Page 1131 and 1132: Field Modification Kits Pilot Light
- Page 1133: Field Modification Kits NEMA, Reduc
- Page 1137 and 1138: Field Modification Kits NEMA, Overl
- Page 1139 and 1140: Heavy Duty Control Non-Combination
- Page 1141 and 1142: Combination Starter Enclosure Kits
- Page 1143 and 1144: Factory Modifications Revised on 03
- Page 1145 and 1146: Factory Modifications Revised on 03
- Page 1147 and 1148: Manual Control Heater Elements, Cla
- Page 1149 and 1150: Replacement Parts Starters and Cont
- Page 1151 and 1152: Replacement Parts Lighting Contacto
- Page 1153 and 1154: Replacement Parts Miscellaneous Sel
- Page 1155 and 1156: Manual Control Class SMF, MMS Dimen
- Page 1157 and 1158: Heavy Duty Motor Starters Solid Sta
- Page 1159 and 1160: Heavy Duty Contactors Class 40 Dime
- Page 1161 and 1162: Overload Relays & Current Transform
- Page 1163 and 1164: Lighting & Heating Contactors Open
- Page 1165 and 1166: GROUND 1/ L1 3/ L2 5/ L3 2/ T1 11 2
- Page 1167 and 1168: Lighting & Heating Contactors Mecha
- Page 1169 and 1170: Heavy Duty Motor Starters & Contact
- Page 1171 and 1172: Combination Heavy Duty Starters Enc
- Page 1173 and 1174: Reversing Heavy Duty Starters & Con
- Page 1175 and 1176: Combination Reversing Heavy Duty St
- Page 1177 and 1178: Combination Two Speed Heavy Duty St
- Page 1179 and 1180: Duplex Heavy Duty Controllers Class
- Page 1181 and 1182: Lighting Contactors Enclosed Contac
- Page 1183 and 1184: Manual Control Class 11 - 3RV, SMF,
Field Modification Kits<br />
NEMA Accessories<br />
Selection<br />
Miscellaneous Kits<br />
Encl. Controller Catalog List<br />
Description Class Type Size Number Price $<br />
Mechanical Interlock 00–1 49CCF22H<br />
for Horizontally<br />
Mounted Contactors<br />
Includes wire<br />
14, 40 Open<br />
1 3 ⁄4 49EEF22H<br />
2, 2 1 ⁄2 49GGF22H<br />
3, 3 1 ⁄2 49HHP22H<br />
4 49JJG22H<br />
Interlock Only 5, 6 3RA1954-2A<br />
5 3RA1963-2A<br />
Wire Kit Only<br />
14, 40 Open 6 3RA1973-2A<br />
5 3RA1962-2A<br />
Base Plate Only<br />
6 3RA1972-2A<br />
7 49VM750H<br />
Mechanical Interlock 14, 40 Open<br />
8 49VM1650H<br />
00–1 49CCF22HP<br />
1 3 ⁄4 49EEF22HP<br />
Includes wire &<br />
14, 40 Open 2, 2 1 ⁄2<br />
mounting plate<br />
49GGF22HP<br />
3, 3 1 ⁄2 49HHP22HP<br />
4 49JJG22HP<br />
Includes Left Right<br />
mounting plate 14, 40 Open 2, 2 1 ⁄2 3, 3 1 ⁄2 49L107944<br />
(Different Frame Sizes) 3, 3 1 ⁄2 2, 2 1 ⁄2 49L107945<br />
Surge Suppressor for 120V AC<br />
Surge coil. Limits transient voltage All but<br />
Suppressor produced by the coil to 220% Class LC, LE, CLM<br />
maximum peak line volts.<br />
All 00–4 a 49D26344<br />
Auxiliary NO 36A at 600V AC Max All but<br />
All<br />
49SAF0<br />
00–13⁄4<br />
Power Pole NC 25A at 600V AC Max Class LC, LE, CLM 49SAFC<br />
Top or Bottom, 2-Pole<br />
CLM4097331<br />
Main Contacts<br />
Top, 3-Pole<br />
CLM4097332<br />
CLM All 20 Amps<br />
Lighting Contactors Top or Bottom, 4-Pole CLM4097333<br />
Top or Bottom, 6-Pole<br />
CLM4097334<br />
Load Side<br />
Includes 3 power lugs<br />
Power Take for making extra All but All 00–1 3 ⁄4 49SAE<br />
Off Kit connections to the load Class LC, LE, CLM<br />
side of the contactor<br />
Lug Kit for Contactors For AL/CU Wire 14, 40 All 2-2 1 ⁄2 49SAAF c<br />
3-3 1 ⁄2 49SAAH c<br />
Item Wire Range<br />
4 Line 4 Load 75D35994002 c<br />
49SAAF 2-14<br />
49SAAH 2/0-14<br />
For AL/CU Wire 14, 40 All 5, 6 3RT1966-4G b<br />
75D35994001 250MCM-6<br />
7 49ZATK750-3<br />
Use CU Only 14, 40 All<br />
8 49ZATK1650-6 b<br />
Three Conductor Ground Lug<br />
Kit Meets UL 508 and CSA 2-14 AWG AL/CU Wire All All All 75D28182001<br />
Standard 22.2 No 14-1973<br />
Lightning Arrestor All All All 49D45584002<br />
NEMA & General<br />
Purpose Control<br />
17 CONTROL<br />
PRODUCTS<br />
Backspin Timer<br />
On delay timer that reduces<br />
risk of starting into a 87, 88 All All<br />
3RP2025-1AQ30<br />
3RP2025-1AP30<br />
backspin<br />
Covers the hole that is<br />
Hole Plug typically used for the 87 All 1-4 49D41149006<br />
conduit hub<br />
Hole Plug<br />
Covers the hole in the enclosure door/cover<br />
40, 43, LC, LE,<br />
normally filled by overload reset 49MBRS.<br />
CLM & CM<br />
Hole plug is used for enclosed contactors.<br />
1 All 49MZPB2<br />
Illustration Description Contactor Wire Size Catalog Number List Price $<br />
Lug Kit<br />
NEMA size 4 (Vacuum)<br />
1 Kit = 1 Terminal block. 1 kit NEMA size 5 2/0 to 600 MCM, max. one 500MCM<br />
necessary for each line and load. NEMA size 6 & one 600MCM<br />
3RT1966-4G<br />
3RT1966-4G<br />
a Surge Suppression for NEMA sizes 5 – 8 are supplied<br />
internal with the coil. For size 4 panel mount.<br />
b Only 3 lugs are suplied for line or load.<br />
If lugs for line and load are required order 2 kits.<br />
c Lug Kit for contactors include 3 lugs for line or load.<br />
75D35994001 for line side.<br />
75D35994002 for load side.<br />
Product Category: NEMA<br />
Siemens Industry, Inc. SPEEDFAX Product Catalog 17-107