17.12.2020 Views

API RP 581 - 3rd Ed.2016 - Add.2-2020 - Risk-Based Inspection Methodology

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2-40 API RECOMMENDED PRACTICE 581

Table 5.3—Data Required for Determination of the Lining DF

Type of lining

Required Data

Age of lining (years)

Comments

See Table 5.4 and Table 5.5, as applicable

Age of lining, or years since last A or B effective inspection (i.e. since last

thorough visual inspection or other appropriate method)

Lining condition Condition of lining based on Table 5.6

On-line monitoring for lining failure

On-line monitoring

Damage factor Thinning DF determined as in Section 4

Table 5.4—Lining DFs—Inorganic Linings

Years Since

Last

Thorough

Visual

Inspection

Strip Lined

Alloy

(Resistant)

Castable

Refractory

DF As a Function of Inorganic Lining Type

Castable

Refractory

Severe

Conditions

Glass Lined Acid Brick Fiberglass

1 0.3 0.5 9 3 0.01 1

2 0.5 1 40 4 0.03 1

3 0.7 2 146 6 0.05 1

4 1 4 428 7 0.15 1

5 1 9 1017 9 1 1

6 2 16 1978 11 1 1

7 3 30 3000 13 1 2

8 4 53 3000 16 1 3

9 6 89 3000 20 2 7

10 9 146 3000 25 3 13

11 12 230 3000 30 4 26

12 16 351 3000 36 5 47

13 22 518 3000 44 7 82

14 30 738 3000 53 9 139

15 40 1017 3000 63 11 228

16 53 1358 3000 75 15 359

17 69 1758 3000 89 19 548

18 89 2209 3000 105 25 808

19 115 2697 3000 124 31 1151

20 146 3000 3000 146 40 1587

21 184 3000 3000 170 50 2119

22 230 3000 3000 199 63 2743

23 286 3000 3000 230 78 3000

24 351 3000 3000 266 97 3000

25 428 3000 3000 306 119 3000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!