5-56 API RECOMMENDED PRACTICE 581

η =

upd

t

( ) 1

prd

− ⎡1−

f ,wgt

ln P β

⎣ ⎦

(5.99)

6) Example—Modified Bayesian Updating Calculation

Consider a conventional PRV that is in a severe fluid service. The default Weibull parameters in

accordance with Table 6.6 are as follows:

β = 1.8 (5.100)

η

= η = 17 6

(5.101)

def mod .

For this example, there are assumed to be no other adjustments, so that the modified

characteristic life value is equal to the default value.

prd

The Pf ,prior

may be determined using Equation (5.102) for any in-service duration. Assuming an

prd

inspection is conducted at an in-service duration of 6 years, the POF at 6 years, P f ,prior

, is:

⎡ 18 .

prd

⎛ 6 ⎞ ⎤

Pf ,prior = 1−exp ⎢− ⎜ ⎟ ⎥ = 01342 .

⎢ ⎝17.

6⎠

⎣ ⎥⎦

(5.102)

The probability that the device will pass a bench test may be determined using Equation (5.103):

P prd

prd

p,prior = 1− P f ,prior = 1− 01342 . = 0 . 8658

(5.103)

These probabilities are defined as the Prior Probabilities.

At the 6-year in-service inspection, a highly effective bench test is performed, and the device

passes the test. Using Table 6.9, a 90 % confidence factor has been estimated for this type of

inspection, meaning that 10 % of devices that pass this type of test would fail on demand in

service. An adjusted or conditional POF is calculated using Equation (5.104):

( pass )

P prd

prd

f ,cond = 1− CF ⋅ P p,prior = 01 . ⋅ 0 . 8658 = 0 . 087

(5.104)

For a highly effective pass, the weighted probability is calculated (see Table 5.10 for equations):

prd prd prd ⎛ t ⎞ prd ⎛ t ⎞

Pf ,wgt = P f ,prior −02 . ⋅P f ,prior ⋅ ⎜ + 02 . ⋅Pf ,cond

⎝η

mod ⎠

⎝η

mod ⎠

(5.105)

or

prd

⎛ 6 ⎞ ⎛ 6 ⎞

P f ,wgt = 01342 . −0. 2⋅01342 . ⋅ ⎜ + 0. 2⋅( 0. 087)

⋅ = 01310 .

17. 6⎠ ⎜

17.

6⎠

(5.106)

Finally, using the prior β and the calculated weighted probability,

prd

P f ,wgt

parameter is calculated for the in-service duration using Equation (5.107).

, an updated value for the η