17.12.2020 Views

API RP 581 - 3rd Ed.2016 - Add.2-2020 - Risk-Based Inspection Methodology

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

RISK-BASED INSPECTION METHODOLOGY, PART 3—CONSEQUENCE OF FAILURE METHODOLOGY 3-121

W

n

is the theoretical release rate associated with the n th release hole size, kg/s (lb/s)

pool

W

n

is the portion of the release rate that forms a pool on the ground associated with the n th release

hole size, kg/s (lb/s)

W

TNT

is the energy released in an explosion expressed as an equivalent mass of TNT, kg (lb)

bleve

xs

cmd

is the safe distance from a BLEVE for component damage associated with the rupture case,

m (ft)

bleve

xs is the safe distance from a BLEVE for personnel injury associated with the rupture case, m (ft)

inj

fball

xs is the safe distance from the flame surface of a fireball, m (ft)

fball

xs

cmd

is the safe distance from a fireball for component damage associated with the rupture case,

m (ft)

fball

xs is the safe distance from a fireball for personnel injury associated with the rupture case, m (ft)

inj

xs is the safe distance from the jet fire flame surface for component damage associated with the

jet

cmd , n

n th release hole size, m (ft)

xs is the safe distance from the jet fire flame surface for personnel injury associated with the n th

jet

inj,

n

release hole size, m (ft)

jet

xs

n

is the safe distance from the jet fire flame surface associated with the n th release hole size, m (ft)

xs

n

is the safe distance from the flame surface to the target location associated with the n th release

hole size, m (ft)

pexp

xs is the safe distance from a physical explosion for component damage associated with the

cmd

rupture case, m (ft)

pexp

xs is the safe distance from a physical explosion for personnel injury associated with the rupture

inj

case, m (ft)

xs is the safe distance from the pool fire flame surface for component damage associated with the

pool

cmd , n

n th release hole size, m (ft)

xs is the safe distance from the pool fire flame surface for personnel injury associated with the n th

pool

inj,

n

release hole size, m (ft)

pool

xs is the safe distance from the pool fire flame surface associated with the n th release hole size, m (ft)

n

xs is the safe distance from the VCE for component damage associated with the n th release hole

vce

cmd , n

size, m (ft)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!