3-50 API RECOMMENDED PRACTICE 581

Table 4.2M—Properties of the Representative Fluids Used in Level 1 Consequence Analysis

Liquid

Ideal Gas

NBP Ambient

Ideal Gas Ideal Gas

Fluid MW Density

Specific

(°C) State

Constant Constant

(kg/m 3 )

Heat Eq.

A B

Cp

Ideal Gas

Constant

C

Ideal Gas

Ideal Gas

Constant

Constant D

E

EEA 132 977.123 156 Liquid Note 2 1.06E+05 2.40E+05 6.59E+02 1.50E+05 1.97E+03 379

EE 90 929.068 135 Liquid Note 2 3.25E+04 3.00E+05 1.17E+03 2.08E+05 4.73E+02 235

EG 62 1105.270 197 Liquid Note 2 6.30E+04 1.46E+05 1.67E+03 9.73E+04 7.74E+02 396

EO 44 881.013 11 Gas Note 2 3.35E+04 1.21E+05 1.61E+03 8.24E+04 7.37E+02 429

AIT

(°C)

NOTE 1

p

2 3

C = A + BT + CT + DT with T in K, units for C p are J/(kg-mol-K).

NOTE 2

2 2

⎛ C ⎞ ⎛ E ⎞

⎜ ⎟ ⎜ ⎟

C

T

T

p = A+ B⎜ ⎟ + D⎜ ⎟

⎜ ⎡C⎤⎟ ⎜ ⎡E⎤⎟

⎜sinh

cosh

T

⎥⎟ ⎠

T

⎥⎟

⎣ ⎦ ⎣ ⎦⎠

with T in K, units for C p are J/(kg-mol-K).

NOTE 3

p

2 3 4

C = A + BT + CT + DT + ET with T in K, units for C p are J/(kg-mol-K).

NOTE 4 Pyrophoric materials, by definition, autoignite and therefore a very low value for the AIT is assumed.