RISK-BASED INSPECTION METHODOLOGY, PART 3—CONSEQUENCE OF FAILURE METHODOLOGY 3-39

AIL CONT

b − inj

is a constant AIL continuous release provided for reference fluids for Level 1 consequence

analysis for personnel injury area

AIL INST

b − cmd is a constant AIL instantaneous release provided for reference fluids for Level 1 consequence

analysis for equipment damage area

AIL INST

b − inj is a constant AIL instantaneous release provided for reference fluids for Level 1 consequence

analysis for personnel injury area

AINL−CONT

b cmd

is a constant AINL continuous release provided for reference fluids for Level 1 consequence

analysis for equipment damage area

AINL−CONT

b inj

AINL−INST

b cmd

is a constant AINL continuous release provided for reference fluids for Level 1 consequence

analysis for personnel injury area

is a constant AINL instantaneous release provided for reference fluids for Level 1 consequence

analysis for equipment damage area

AINL−INST

b inj

c

C

d

is a constant AINL instantaneous release provided for reference fluids for Level 1 consequence

analysis for personnel injury area

is a gas release constant used in HF and H2S releases for the COF 1 toxic area analysis

is the release hole coefficient of discharge, unitless

C

p

is the specific heat of the released fluid, J/kg-K (Btu/lb-°R)

CA

f

is the final consequence area, m 2 (ft 2 )

acid

CA

inj,

n

is the personnel injury consequence area for caustic and acid leaks, associated with the n th

release hole size, m 2 (ft 2 )

AIL

CA is the flammable consequence area where autoignition is likely to occur, m 2 (ft 2 )

CA is the continuous/instantaneous blended component damage flammable consequence area that

AIL

cmd , n

AIL CONT

cmd , n

is likely to autoignite, associated with the n th release hole size, m 2 (ft 2 )

CA − is the component damage flammable consequence area for continuous releases that is likely to

AIL CONT

inj,

n

autoignite, associated with the n th release hole size, m 2 (ft 2 )

CA − is the personnel injury flammable consequence area for continuous releases that is likely to

AIL INST

cmd , n

autoignite, associated with the n th release hole size, m 2 (ft 2 )

CA − is the component damage flammable consequence area for instantaneous releases that is likely

to autoignite, associated with the n th release hole size, m 2 (ft 2 )