2.C-8 API RECOMMENDED PRACTICE 581

2.C.5.2 Tables

Table 2.C.5.1—LoIE Example for AST Shell Course Internal Corrosion

Inspection

Category

A

B

Inspection

Effectiveness

Category

Highly

Effective

Usually

Effective

Inspection a

Both inspections shall be done:

— intrusive inspection—good visual inspection with pit depth gage measurements

at suspect locations

— UT scanning follow up on suspect location and as general confirmation of wall

thickness

Both inspections shall be done:

— external spot UT scanning based on visual information from previous internal

inspection of this AST or similar service ASTs

— internal video survey with external UT follow-up

C Fairly Effective External spot UT scanning based at suspect locations without benefit of any internal

inspection information on AST type or service

D

Poorly

Effective

External spot UT based at suspect locations without benefit of any internal

inspection information on AST type or service

E Ineffective Ineffective inspection technique/plan was utilized