2.B-116 API RECOMMENDED PRACTICE 581Table 2.B.14.9—Soil-Side Temperature AdjustmentSoil-Side Temperature°C °FMultiplying Factor—F STTemp ≤ 24 Temp ≤ 75 1.024 < Temp ≤ 66 75 < Temp ≤ 150 1.166 < Temp ≤ 93 150 < Temp ≤ 200 1.393 < Temp ≤ 121 200 < Temp ≤ 250 1.4>121 >250 1.0Table 2.B.14.10—Summary of Conditions for Product-Side Base Corrosion RateFactorInternal coatingBulk fluid temperatureSteam coil heaterWater drawsBase Corrosion Rate ConditionsInternal coating not needed for corrosion protection and none appliedBelow 24 °C (75 °F)NoNo (water draws conducted neither weekly nor after every receipt)Table 2.B.14.11—Product-Side Product Condition AdjustmentProduct-Side ConditionMultiplying Factor—F PCWet 2.5Dry 1.0Table 2.B.14.12—Product-Side Temperature AdjustmentProduct-Side Temperature°C °FMultiplying Factor—F PTTemp ≤ 24 Temp ≤ 75 1.024 < Temp ≤ 66 75 < Temp ≤ 150 1.166 < Temp ≤ 93 150 < Temp ≤ 200 1.393 < Temp ≤ 121 200 < Temp ≤ 250 1.4>121 >250 1.0Table 2.B.14.13—Product-Side Steam Coil AdjustmentSteam CoilMultiplying Factor—F SCNo 1.0Yes 1.15

RISK-BASED INSPECTION METHODOLOGY, PART 2, ANNEX 2.B—DETERMINATION OF CORROSION RATES 2.B-117Table 2.B.14.14—Product-Side Water Draw-off AdjustmentWater Draw-offMultiplying Factor—F WD2.B.14.6FiguresSoil SideNo 1.0Yes 0.7Product Side• Average time toleakage• Thickness• “Default” = 5 mpyEstablish Base CorrosionRate for Soil Side CorrosionEstablish Base CorrosionRate for InternalBottom Corrosion• Inspection Data• BS&W• pHResistivityDetermine Adjustment factorfor Soil ConditionsTank Pad TypeDetermine Adjustment factorfor Tank Pad MaterialDetermine Adjustment factorfor Product ConditionsProduct ConditionsWater DrainageDetermine Adjustment factorfor DrainageDetermine Adjustment factorfor Operating TemperatureBulk FluidTemperatureCathodic ProtectionDetermine Adjustment factorfor Cathodic ProtectionDetermine Adjustment factorfor Steam Coil HeaterUse of Steam CoilHeaterBottom DesignDetermine Adjustment factorfor Bottom TypeDetermine Adjustment factorfor Water DrawsWater DrawBulk FluidTemperatureDetermine Adjustment factorfor Operating TemperatureCalculate Modified Soil SideCorrosion Rate(Always Localized)Calculate ModifiedProduct SideCorrosion Rate(Widespread or Localized)Product Side CRWidespreadIsProduct SideBottom CorrosionWidespread orLocalizedProduct Side CRLocalizedSum Corrosion RatesUse the GreaterOf Corrosion RatesFinal EstimatedCorrosion RateFigure 2.B.14.1—AST Bottom Corrosion—Determination of Soil-Side and Product-Side Corrosion Rates

2.B-116 API RECOMMENDED PRACTICE 581

Table 2.B.14.9—Soil-Side Temperature Adjustment

Soil-Side Temperature

°C °F

Multiplying Factor—F ST

Temp ≤ 24 Temp ≤ 75 1.0

24 < Temp ≤ 66 75 < Temp ≤ 150 1.1

66 < Temp ≤ 93 150 < Temp ≤ 200 1.3

93 < Temp ≤ 121 200 < Temp ≤ 250 1.4

>121 >250 1.0

Table 2.B.14.10—Summary of Conditions for Product-Side Base Corrosion Rate

Factor

Internal coating

Bulk fluid temperature

Steam coil heater

Water draws

Base Corrosion Rate Conditions

Internal coating not needed for corrosion protection and none applied

Below 24 °C (75 °F)

No

No (water draws conducted neither weekly nor after every receipt)

Table 2.B.14.11—Product-Side Product Condition Adjustment

Product-Side Condition

Multiplying Factor—F PC

Wet 2.5

Dry 1.0

Table 2.B.14.12—Product-Side Temperature Adjustment

Product-Side Temperature

°C °F

Multiplying Factor—F PT

Temp ≤ 24 Temp ≤ 75 1.0

24 < Temp ≤ 66 75 < Temp ≤ 150 1.1

66 < Temp ≤ 93 150 < Temp ≤ 200 1.3

93 < Temp ≤ 121 200 < Temp ≤ 250 1.4

>121 >250 1.0

Table 2.B.14.13—Product-Side Steam Coil Adjustment

Steam Coil

Multiplying Factor—F SC

No 1.0

Yes 1.15