RISK-BASED INSPECTION METHODOLOGY, PART 2, ANNEX 2.B—DETERMINATION OF CORROSION RATES 2.B-91

Table 2.B.11.6—Flow Velocity Adjustment Factor (F V ) as a Function of the Flow Velocity

Flow Velocity

m/s

ft/s

F V —Flow Velocity Factor

0.15 0.5 2.25

0.3 1 2

0.61 2 1.5

0.91 3 1

1.22 4 1

1.52 5 1

1.83 6 1

2.13 7 1

2.44 8 1

2.74 9 1.25

3.05 10 1.5

3.35 11 1.75

3.66 12 2

3.96 13 2.25

4.27 14 2.5

4.57 15 2.75

4.88 16 3

5.18 17 3.25

5.49 18 3.5

5.79 19 3.75

6.1 20 4