2.B-90 API RECOMMENDED PRACTICE 581

Table 2.B.11.5—Temperature Adjustment Factor, F T , as a Function of the Operating Temperature

Operating Temperature (°F)

°C °F

F T for Closed Systems

F T for Open Systems

24 75 0.1 0.1

27 80 0.3 0.3

29 85 0.4 0.4

32 90 0.6 0.6

35 95 0.8 0.8

38 100 0.9 0.9

41 105 1.1 1.1

43 110 1.2 1.2

46 115 1.4 1.4

49 120 1.6 1.6

52 125 1.7 1.7

54 130 1.9 1.9

57 135 2.1 2.1

60 140 2.2 2.2

63 145 2.4 2.4

66 150 2.5 2.5

68 155 2.7 2.7

71 160 2.9 2.9

74 165 3.0 3.0

77 170 3.2 3.2

79 175 3.4 3.3

82 180 3.5 3.3

85 185 3.7 3.3

88 190 3.8 3.3

91 195 4.0 3.1

93 200 4.2 2.9

41 105 4.3 2.5

99 210 4.5 1.7