2.B-74 API RECOMMENDED PRACTICE 581Table 2.B.10.3—Acid Sour Water Corrosion—Basic Data Required for AnalysisOxygen ContentAdjustment Factor—F oNot significant (≤50 ppb) 1.0High (>50 ppb) 2.0

RISK-BASED INSPECTION METHODOLOGY, PART 2, ANNEX 2.B—DETERMINATION OF CORROSION RATES 2.B-752.B.10.7FiguresStartIs H 2 0Present?YesDetermine pHIspH > 7?YesProceed toParagraph 2.B.7.NoNoEstimated CorrosionRate is 0NoIspH < 4.5?YesAre ChloridesPresent?YesProceed toParagraph 2.B.2.NoMaterial ofconstruction iscarbon or lowalloy?NoCR=2mpyYesDetermine corrosionrate CR pH fromTable 2.B.10.2.• pH• Temperature °FDetermine adjustmentfactor for oxygen FromTable 2.B.10.3.Oxygen (ppb)Determine adjustmentfactor for velocity F v fromEquations 2.B.2 to 2.B.4.Velocity (fps)Calculate Final CorrosionRateCR = CR pH x F o x F vEstimatedCorrosion RateFigure 2.B.10.1—Acid Sour Water—Determination of Corrosion Rate

2.B-74 API RECOMMENDED PRACTICE 581

Table 2.B.10.3—Acid Sour Water Corrosion—Basic Data Required for Analysis

Oxygen Content

Adjustment Factor—F o

Not significant (≤50 ppb) 1.0

High (>50 ppb) 2.0