2-156 API RECOMMENDED PRACTICE 581

23.10 Figures

STEP 1: Determine the evaluation temperature:

• Normal operating temperature

• Shutdown temperature

• Upset temperature

STEP 2: Determine the estimated Sigma from:

• Comparisons with other materials

• Metallographic examination

STEP 3: Determine the Damage Factor using

Table 23.3.

Figure 23.1—Determination of the Sigma Phase Embrittlement DF

24 Piping Mechanical Fatigue DF

24.1 Scope

The DF calculation for piping components subject to mechanical fatigue is covered in this section.

24.2 Description of Damage

Fatigue failures of piping systems present a very real hazard under certain conditions. Properly designed and

installed piping systems should not be subject to such failures, but prediction of vibration in piping systems at

the design stage is very difficult, especially if there are mechanical sources of cyclic stresses such as

reciprocating pumps and compressors. In addition, even if a piping systems are not subject to mechanical

fatigue in the as-built condition, changing conditions such as failure of pipe supports, increased vibration

from out of balance machinery, chattering of relief valves during process upsets, changes in flow and

pressure cycles, or adding weight to unsupported branch connections (pendulum effect) can render a piping

system susceptible to failure. Awareness of these influences incorporated into a management of change

program can reduce the POF.

24.3 Screening Criteria

If both of the following are true, then the component should be evaluated for susceptibility to mechanical

fatigue.

a) The component is pipe.

b) There have been past fatigue failures in this piping system or there is visible/audible shaking in this piping

system or there is a source of cyclic vibration within approximately 15.24 m (50 ft) and connected to the

piping (directly or indirectly via structure). Shaking and source of shaking can be continuous or intermittent.

Transient conditions often cause intermittent vibration.

24.4 Required Data

The basic component data required for analysis are given in Table 4.1, and the specific data required for

determination of the DF for mechanical fatigue are provided in Table 24.1.